Computerized tomography based "patient specific blocks" improve postoperative mechanical alignment in primary total knee arthroplasty.

Raju Vaishya1, Vipul Vijay1, Vikas P Birla1, Amit K Agarwal1.   

Abstract

AIM: To compare the postoperative mechanical alignment achieved after total knee arthroplasty (TKA) using computer tomography (CT) based patient specific blocks (PSB) to conventional instruments (CI).
METHODS: Total 80 knees were included in the study, with 40 knees in both the groups operated using PSB and CI. All the knees were performed by a single surgeon using the same cruciate sacrificing implants. In our study we used CT based PSB to compare with CI. Postoperative mechanical femoro-tibial angle (MFT angle) was measured on long leg x-rays using picture archiving and communication system (PACS). We compared mechanical alignment achieved using PSB and CI in TKA using statistical analysis.
RESULTS: The PSB group (group 1) included 17 females and seven males while in CI group (group 2) there were 15 females and eight males. The mean age of patients in group 1 was 60.5 years and in group 2 it was 60.2 years. The mean postoperative MFT angle measured on long-leg radiographs in group 1 was 178.23° (SD = 2.67°, range: 171.9° to 182.5°) while in group 2, the mean MFT angle was 175.73° (SD = 3.62°, range: 166.0° to 179.8°). There was significant improvement in postoperative mechanical alignment (P value = 0.001), in PSB group compared to CI. Number of outliers were also found to be less in group operated with PSB (7 Knee) compared to those operated with CI (17 Knee).
CONCLUSION: PSB improve mechanical alignment after total knee arthroplasty, compared to CI. This may lead to lower rates of revision in the PSB based TKA as compared to the conventional instrumentation.

Entities:  

Keywords:  Arthroplasty; Conventional jigs; Knee; Patient specific jigs; Replacement

Year:  2016        PMID: 27458553      PMCID: PMC4945509          DOI: 10.5312/wjo.v7.i7.426

Source DB:  PubMed          Journal:  World J Orthop        ISSN: 2218-5836


  30 in total

Review 1.  Computer assisted navigation in knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2011-12-01

2.  Custom-fit total knee arthroplasty (OtisKnee) results in malalignment.

Authors:  Brian A Klatt; Nitin Goyal; Matthew S Austin; William J Hozack
Journal:  J Arthroplasty       Date:  2008-01       Impact factor: 4.757

3.  A comparison of patient-specific and conventional instrumentation for total knee arthroplasty: a multicentre randomised controlled trial.

Authors:  L Abane; P Anract; S Boisgard; S Descamps; J P Courpied; M Hamadouche
Journal:  Bone Joint J       Date:  2015-01       Impact factor: 5.082

Review 4.  The new technologies in knee arthroplasty.

Authors:  Carlos A Higuera; Carl Deirmengian
Journal:  J Clin Rheumatol       Date:  2012-10       Impact factor: 3.517

5.  Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA.

Authors:  Vincent Y Ng; Jeffrey H DeClaire; Keith R Berend; Bethany C Gulick; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

6.  Computer-assisted total knee arthroplasty using patient-specific templating.

Authors:  M A Hafez; K L Chelule; B B Seedhom; K P Sherman
Journal:  Clin Orthop Relat Res       Date:  2006-03       Impact factor: 4.176

7.  Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation.

Authors:  Corey Scholes; Varun Sahni; Sebastien Lustig; David A Parker; Myles R J Coolican
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-17       Impact factor: 4.342

8.  Mechanical axis cannot be restored in total knee arthroplasty with a fixed valgus resection angle: a radiographic study.

Authors:  Nicholas Bardakos; Akin Cil; Brandon Thompson; Greg Stocks
Journal:  J Arthroplasty       Date:  2007-07-26       Impact factor: 4.757

9.  Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation.

Authors:  Sébastien Parratte; Guillaume Blanc; Thomas Boussemart; Matthieu Ollivier; Thomas Le Corroller; Jean-Noël Argenson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-14       Impact factor: 4.342

10.  Outcome of subvastus approach in elderly nonobese patients undergoing bilateral simultaneous total knee arthroplasty: A randomized controlled study.

Authors:  Raju Vaishya; Ajay Pal Singh; Abhishek Vaish
Journal:  Indian J Orthop       Date:  2013-07       Impact factor: 1.251

View more
  7 in total

1.  Fallacies of CT based component size prediction in total knee arthroplasty - Are patient specific instruments the answer?

Authors:  Raju Vaishya; Vipul Vijay; Midhun Krishnan; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2017-11-10

Review 2.  Computed tomography based 3D printed patient specific blocks for total knee replacement.

Authors:  Raju Vaishya; Vipul Vijay; Abhishek Vaish; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2018-07-18

3.  Fixed distal femoral valgus cutting angle is still justifiable in total knee replacement.

Authors:  Raju Vaishya; Vipul Vijay; Edwin O Edomwonyi; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2017-03-06

4.  Biomechanical Characteristics of Three Baseplate Rotational Arrangement Techniques in Total Knee Arthroplasty.

Authors:  KwanSu Kang; Young Woong Jang; Oui Sik Yoo; Dukyoung Jung; Sung-Jae Lee; Myung Chul Lee; Dohyung Lim
Journal:  Biomed Res Int       Date:  2018-06-06       Impact factor: 3.411

5.  Advantages of patient-specific cutting guides with disposable instrumentation in total knee arthroplasty: a case control study.

Authors:  Kevin Moerenhout; Behrang Allami; Georgios Gkagkalis; Olivier Guyen; Brigitte M Jolles
Journal:  J Orthop Surg Res       Date:  2021-03-15       Impact factor: 2.359

Review 6.  Publication trends and knowledge mapping in 3D printing in orthopaedics.

Authors:  Raju Vaishya; Mohit Kumar Patralekh; Abhishek Vaish; Amit Kumar Agarwal; Vipul Vijay
Journal:  J Clin Orthop Trauma       Date:  2018-07-30

7.  Integration of Three-dimensional Technologies in Orthopedics: A Tool for Preoperative Planning of Tibial Plateau Fractures.

Authors:  Flaviu Moldovan; Adrian Gligor; Tiberiu Bataga
Journal:  Acta Inform Med       Date:  2020-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.