Literature DB >> 17195810

Alignments and clinical results in conventional and navigated total knee arthroplasty.

A Ensini1, F Catani, A Leardini, M Romagnoli, S Giannini.   

Abstract

In this prospective, randomized, controlled study, we compared the performance of conventional and navigated total knee arthroplasties. Component alignment was measured in 60 patients operated on using navigation and in 60 patients operated on using the conventional technique. The groups then were divided into a subpopulation to measure alignments of the distal femoral cuts in the three anatomic planes, the proximal tibial cut in the frontal and sagittal planes, and the resulting lower limb mechanical axis in the frontal plane. Postoperative weightbearing long-view radiographs were evaluated as were clinical results using three standard questionnaires at 28 months followup. The intraoperative measurements (mean +/- standard deviation) at the resection planes showed navigated surgeries result in more accurate alignments than conventional surgeries for the femur: in the frontal plane, 0.1 degrees +/- 0.9 degrees and 0.7 degrees +/- 1.6 degrees valgus, respectively; in the sagittal plane, 1.1 degrees +/- 1.8 degrees and 2.8 degrees +/- 2.0 degrees flexion; and in the transversal plane, 0.1 degrees +/- 1.2 degrees and 0.9 degrees +/- 1.7 degrees internal rotation. The navigated technique also reduced the number of cases with final mechanical axes greater than 3 degrees from 20.0% to 1.7%. Postoperative radiographs showed better component alignment using navigation, particularly at the femur. However, clinical scoring systems showed this radiographic improvement did not necessarily result in a better clinical outcome at short-term followup.

Entities:  

Mesh:

Year:  2007        PMID: 17195810     DOI: 10.1097/BLO.0b013e3180316c92

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  61 in total

Review 1.  Alignment outcomes in navigated total knee arthroplasty: a meta-analysis.

Authors:  Yonghui Fu; Mingming Wang; Yifeng Liu; Qin Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-15       Impact factor: 4.342

2.  Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies.

Authors:  Yaron S Brin; Vassilios S Nikolaou; Lawrence Joseph; David J Zukor; John Antoniou
Journal:  Int Orthop       Date:  2010-04-08       Impact factor: 3.075

3.  Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty.

Authors:  Jae Han Ko; Chang Dong Han; Kyoo Ho Shin; Levis Nguku; Ick Hwan Yang; Woo Suk Lee; Kwang Il Kim; Kwan Kyu Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-18       Impact factor: 4.342

4.  Differences between sagittal femoral mechanical and distal reference axes should be considered in navigated TKA.

Authors:  Byung June Chung; Yeon Gwi Kang; Chong Bum Chang; Sung Ju Kim; Tae Kyun Kim
Journal:  Clin Orthop Relat Res       Date:  2009-02-26       Impact factor: 4.176

5.  Navigation did not improve the precision of minimally invasive knee arthroplasty.

Authors:  Peter M Bonutti; Daniel A Dethmers; Mike S McGrath; Slif D Ulrich; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2008-07-10       Impact factor: 4.176

6.  Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty.

Authors:  Mui-Hong Lim; Andras Tallay; John Bartlett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-31       Impact factor: 4.342

7.  Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study.

Authors:  Mark Yaffe; Michael Luo; Nitin Goyal; Philip Chan; Anay Patel; Max Cayo; S David Stulberg
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-13       Impact factor: 2.924

8.  Navigated total knee arthroplasty: is it error-free?

Authors:  Kerk Hsiang Zackary Chua; Yongsheng Chen; Krishna Lingaraj
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-06       Impact factor: 4.342

9.  How to improve femoral component rotational alignment in computer-assisted TKA.

Authors:  F Zambianchi; T Luyckx; J Victor; V Digennaro; A Giorgini; F Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-10       Impact factor: 4.342

10.  Changes in hindfoot alignment after total knee arthroplasty in knee osteoarthritic patients with varus deformity.

Authors:  Woo-Shin Cho; Hun-Sik Cho; Seong-Eun Byun
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-16       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.