Zheng Wang1, Wei Jiang, Yuanming Feng, Yang Guo, Zheng Cong, Bin Song, Yu Guo.
Abstract
PURPOSE: To develop a new IMRT technique to simplify the process and improve efficiency in radiotherapy treatment planning for craniospinal irradiation (CSI) treatment.Entities:
Mesh:
Year: 2013 PMID: 24044521 PMCID: PMC3851431 DOI: 10.1186/1748-717X-8-217
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Patient demographics
| 1 | M | 8 | GCT | 62.3 |
| 2 | M | 35 | MM | 78.6 |
| 3 | M | 13 | GCT | 64.7 |
| 4 | M | 14 | Ependymoma | 67.9 |
| 5 | M | 26 | GCT | 70.8 |
| 6 | F | 30 | MM | 76.2 |
| 7 | F | 14 | GCT | 62.5 |
| 8 | M | 10 | GCT | 68.3 |
| 9 | F | 24 | MM | 75.6 |
Patient demographics at time of CT scan acquisition.
Abbrevations: PTV Planning target volume, M male, F female, GCT Germ cell tumor, MM Medublastoma.
Figure 1Beam arrangements for TIOJ plan and TIJJ plan. Sagittal view shows beam arrangements for both cranial and spinal regions for TIOJ plan (a) and TIJJ plan (b). The conventional plan figure shows the placement of isocenters in a TIOJ plan has beams with shorter source to surface distances (SSDs) which make the distances between the MLC and the spinal cord shorter.
Figure 2Dose volume histogram (DVH) comparison of target coverage. DVH of a representative plan comparing target coverage between the TIOJ plan and the TIJJ plan. The target coverage of both plans meet the initial goal for the target volume coverage.
Evaluation parameters for TIOJ and TIJJ plans
| 1 | 0.083 | 0.086 | 0.83 | 0.83 |
| 2 | 0.072 | 0.072 | 0.74 | 0.78 |
| 3 | 0.070 | 0.070 | 0.81 | 0.80 |
| 4 | 0.083 | 0.085 | 0.86 | 0.84 |
| 5 | 0.061 | 0.063 | 0.80 | 0.78 |
| 6 | 0.070 | 0.070 | 0.79 | 0.79 |
| 7 | 0.061 | 0.060 | 0.81 | 0.81 |
| 8 | 0.070 | 0.070 | 0.83 | 0.72 |
| 9 | 0.069 | 0.081 | 0.76 | 0.69 |
| Mean ± variance | 0.071 ± 0.003 | 0.077 ± 0.002 | 0.80 ± 0.012 | 0.80 ± 0.009 |
Abbrevations: CI conformity index, HI homogeneity index.
Figure 3Isodose distribution of Patient 5 for TIOJ plan and TIJJ plan. Isodose distribution on a midline sagittal CT slice of Patient 5 for TIOJ plan (a) and TIJJ plan (b). Color legend indicates isodose lines, in centigrays. Planning target volume is shown in pink.
Figure 4Median and variation. Median and variation (shown as bars) of mean doses to OARs in TIOG (shade) and TIJJ (white) plans. L: Left; R: right.
Figure 5QA results in the overlapping spinal cord region with TIOJ plan for patient 5. (a) and (c) show the coronal plane dose distributions and profiles for the spinal-spinal junction. The black lines indicate the junction regions. (b) shows the gamma index (3% for absolute dose and 3 mm) for the relative dose evaluation.