Literature DB >> 23990448

In vivo determination of cam-post engagement in fixed and mobile-bearing TKA.

Sumesh M Zingde1, Filip Leszko, Adrija Sharma, Mohamed R Mahfouz, Richard D Komistek, Douglas A Dennis.   

Abstract

BACKGROUND: Kinematics vary, sometimes in important ways, among the different types of total knee arthroplasty (TKA) designs, yet differences between the in vivo mechanisms of cam-post engagement in rotating-platform posterior-stabilized (PS) TKA, bicruciate-stabilized TKA, and fixed-bearing PS TKA designs remain largely uncharacterized. QUESTIONS/PURPOSES: The objective of this study was to determine the cam-post mechanism interaction for subjects implanted with three different TKA designs.
METHODS: In vivo, analysis was conducted for patients implanted with nine rotating-platform PS TKAs, five knees with a fixed-bearing PS TKA, and 10 knees with a bicruciate-stabilized TKA while performing a deep knee bend. Three-dimensional kinematics of the implant components were determined by analysis of fluoroscopic images during flexion. The distances between the interacting surfaces were measured throughout flexion and instances and locations of contact were identified.
RESULTS: Seven of the 10 bicruciate-stabilized knees analyzed had the femoral component engaged with the anterior aspect of the tibial post at full extension. Posterior cam-post engagement occurred at 34° for the bicruciate-stabilized (range, 17°-68°), 93° for the fixed-bearing PS (range, 88°-100°), and at 97° (range, 90°-104°) for rotating-platform PS TKA. In bicruciate-stabilized and fixed-bearing PS knees, the contact initially occurred on the medial aspect of the posterior surface of the tibial post and then moved centrally and superiorly with increasing flexion. For rotating-platform PS TKA, it was located centrally on the posterior surface of the post at all times.
CONCLUSIONS: This study suggests that mobility of the polyethylene might play an important role in ensuring central cam-post interaction in PS TKA. The polyethylene insert rotates axially in accordance with the rotating femur, maintaining central cam-post contact. This phenomenon was not observed in the fixed-bearing PS TKAs analyzed in this study. CLINICAL RELEVANCE: We speculate that this centralized symmetrical contact between the cam and posterior surface of the post could be beneficial clinically in terms of reducing wear of the posterior surface and particularly at the medial extremes of it.

Entities:  

Mesh:

Year:  2014        PMID: 23990448      PMCID: PMC3889432          DOI: 10.1007/s11999-013-3257-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  26 in total

1.  Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns.

Authors:  John Fisher; Hannah M J McEwen; Joanne L Tipper; Alison L Galvin; Jo Ingram; Amir Kamali; Martin H Stone; Eileen Ingham
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

2.  Rotating platform knees did not improve patellar tracking: a prospective, randomized study of 240 primary total knee arthroplasties.

Authors:  Mark W Pagnano; Robert T Trousdale; Michael J Stuart; Arlen D Hanssen; David J Jacofsky
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

3.  In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.

Authors:  Douglas A Dennis; Mohamed R Mahfouz; Richard D Komistek; William Hoff
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

4.  In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty.

Authors:  Jean-Noël A Argenson; Giles R Scuderi; Richard D Komistek; W Norman Scott; Michael A Kelly; Jean-Manuel Aubaniac
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

5.  Wear-simulation analysis of rotating-platform mobile-bearing knees.

Authors:  John Fisher; Hannah McEwen; Joanne Tipper; Louise Jennings; Richard Farrar; Martin Stone; Eileen Ingham
Journal:  Orthopedics       Date:  2006-09       Impact factor: 1.390

6.  In vivo determination of total knee arthroplasty kinematics: a multicenter analysis of an asymmetrical posterior cruciate retaining total knee arthroplasty.

Authors:  Richard D Komistek; Mohamed R Mahfouz; Kim C Bertin; Aaron Rosenberg; William Kennedy
Journal:  J Arthroplasty       Date:  2007-09-24       Impact factor: 4.757

7.  In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty.

Authors:  Hal E Cates; Richard D Komistek; Mohamed R Mahfouz; Monica A Schmidt; Matthew Anderle
Journal:  J Arthroplasty       Date:  2008-03-14       Impact factor: 4.757

8.  The long-term results of simultaneous fixed-bearing and mobile-bearing total knee replacements performed in the same patient.

Authors:  Y-H Kim; S-H Yoon; J-S Kim
Journal:  J Bone Joint Surg Br       Date:  2007-10

9.  Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics.

Authors:  Jeremy F Suggs; George R Hanson; Sang Eun Park; Angela L Moynihan; Guoan Li
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-01-09       Impact factor: 4.342

Review 10.  Factors affecting flexion after total knee arthroplasty.

Authors:  Douglas A Dennis; Richard D Komistek; Giles R Scuderi; Sumesh Zingde
Journal:  Clin Orthop Relat Res       Date:  2007-11       Impact factor: 4.176

View more
  10 in total

1.  Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty.

Authors:  Tae Woo Kim; Sang Min Lee; Sang Cheol Seong; Sahnghoon Lee; Jak Jang; Myung Chul Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-08       Impact factor: 4.342

2.  Analysis of differences in bone removal during femoral box osteotomy for primary total knee arthroplasty.

Authors:  Angelo Graceffa; Pier Francesco Indelli; Kaitlyn Basnett; Massimiliano Marcucci
Journal:  Joints       Date:  2014-07-08

3.  Geometric variable designs of cam/post mechanisms influence the kinematics of knee implants.

Authors:  Ali Fallahiarezoodar; Mohammed Rafiq Abdul Kadir; Mina Alizadeh; Sangeetha Vasudevaraj Naveen; T Kamarul
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-23       Impact factor: 4.342

4.  In vivo kinematics and ligamentous function of the knee during weight-bearing flexion: an investigation on mid-range flexion of the knee.

Authors:  Zhitao Rao; Chaochao Zhou; Willem A Kernkamp; Timothy E Foster; Hany S Bedair; Guoan Li
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-04-10       Impact factor: 4.342

5.  Slow gait speed after bilateral total knee arthroplasty is associated with suboptimal improvement of knee biomechanics.

Authors:  Du Hyun Ro; Hyuk-Soo Han; Dong Yeon Lee; Seong Hwan Kim; Yoon-Ho Kwak; Myung Chul Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-28       Impact factor: 4.342

6.  Confirmation of long-term in vivo bearing mobility in eight rotating-platform TKAs.

Authors:  Michael T LaCour; Adrija Sharma; Christopher B Carr; Richard D Komistek; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2014-04-26       Impact factor: 4.176

Review 7.  Three-dimensional motion analysis and its application in total knee arthroplasty: what we know, and what we should analyze.

Authors:  Yoshio Koga
Journal:  J Orthop Sci       Date:  2015-01-22       Impact factor: 1.601

8.  Fracture of the insert cone of a polyethylene liner in a failed posterior-stabilized, rotating-platform total knee arthroplasty.

Authors:  Marc R Angerame; Jason M Jennings; Douglas A Dennis
Journal:  Arthroplast Today       Date:  2017-11-07

9.  Mobile-bearing insert used with total knee arthroplasty does not rotate on the tibial tray during a squatting activity: a cross-sectional study.

Authors:  Kenji Hoshi; Goro Watanabe; Yasuo Kurose; Ryuji Tanaka; Jiro Fujii; Kazuyoshi Gamada
Journal:  J Orthop Surg Res       Date:  2020-03-20       Impact factor: 2.359

10.  Optimal Sagittal Insertion Depth and Direction of Femoral Intramedullary Rod in Total Knee Arthroplasty in Chinese Osteoarthritis Patients.

Authors:  Yong-Liang Ou; Ping-Yue Li; Hong Xia
Journal:  Orthop Surg       Date:  2020-07-16       Impact factor: 2.071

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.