Literature DB >> 25567541

Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty.

Tae Woo Kim1, Sang Min Lee2, Sang Cheol Seong3, Sahnghoon Lee4, Jak Jang5, Myung Chul Lee6.   

Abstract

PURPOSE: There remains no consensus as to whether mobile total knee arthroplasty (TKA) should use a posterior cruciate ligament-sacrificing ultracongruent (UC) or a posterior cruciate ligament-substituting posterior stabilized (PS) prosthesis. The purpose of this study was to assess intraoperative kinematics and clinical outcomes of UC and PS rotating platform mobile-bearing TKA.
METHODS: In this randomized controlled study, mobile UC TKA prostheses (n = 45) were compared with mobile PS TKA prostheses (n = 45) with regard to intraoperative kinematics and clinical outcomes. The passive kinematic study using intraoperative navigation system included anterior/posterior translation, varus/valgus alignment and rotation of femur during flexion. The patients were clinically and radiographically evaluated over a 3-year follow-up.
RESULTS: Paradoxical anterior translation of the femur was 10.8 ± 5.2 mm in the UC knee from 0° to 82° of knee flexion and 8.7 ± 3.0 mm in the PS knee from 0° to 70° of knee flexion (p = 0.027). Paradoxical internal rotation of the femur was 5.8° in the UC knees and 9.9° in the PS knees (p = 0.003). But, there was no significant difference between the groups in regard to the coronal alignment. There was no significant difference in the range of motion, KS knee scores, KS function scores, and WOMAC index scores.
CONCLUSIONS: Despite different intraoperative kinematics between mobile UC and mobile PS TKA, neither design reproduced physiologic knee kinematics and there was no difference in clinical outcomes between the two groups. The clinical relevance of the study is that despite different intraoperative kinematics, UC design can be a considerable alternative to PS design in mobile-bearing TKA in respect of clinical outcomes. LEVEL OF EVIDENCE: II.

Entities:  

Keywords:  Clinical outcome; Kinematics; Posterior stabilized; Total knee arthroplasty; Ultracongruent

Mesh:

Year:  2015        PMID: 25567541     DOI: 10.1007/s00167-014-3489-0

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  36 in total

1.  Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris.

Authors:  S K Puloski; R W McCalden; S J MacDonald; C H Rorabeck; R B Bourne
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

2.  Multicenter determination of in vivo kinematics after total knee arthroplasty.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz; Brian D Haas; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

3.  Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate?

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz; Joel T Outten; Adrija Sharma
Journal:  Clin Orthop Relat Res       Date:  2005-11       Impact factor: 4.176

4.  Patellofemoral pressure after TKA in vitro: highly conforming vs. posterior stabilized inlays.

Authors:  Thomas Jan Heyse; Christoph Becher; Nadine Kron; Sven Ostermeier; Christof Hurschler; Markus D Schofer; Carsten O Tibesku; Susanne Fuchs-Winkelmann
Journal:  Arch Orthop Trauma Surg       Date:  2009-07-04       Impact factor: 3.067

5.  Knee joint loading and tibial component loosening. RSA and gait analysis in 45 osteoarthritic patients before and after TKA.

Authors:  M B Hilding; H Lanshammar; L Ryd
Journal:  J Bone Joint Surg Br       Date:  1996-01

6.  Loosening and osteolysis with the press-fit condylar posterior-cruciate-substituting total knee replacement.

Authors:  S A Mikulak; O M Mahoney; M A dela Rosa; T P Schmalzried
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

7.  Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study.

Authors:  R S Laskin; Y Maruyama; M Villaneuva; R Bourne
Journal:  Clin Orthop Relat Res       Date:  2000-11       Impact factor: 4.176

8.  Fifteen-year survival and osteolysis associated with a modular posterior stabilized knee replacement. A concise follow-up of a previous report.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  J Bone Joint Surg Am       Date:  2009-06       Impact factor: 5.284

9.  Preservation of the posterior cruciate ligament is not helpful in highly conforming mobile-bearing total knee arthroplasty: a randomized controlled study.

Authors:  Yoon Whan Roh; Jak Jang; Won Chul Choi; Joon Kyu Lee; Sae Hyung Chun; Sahnghoon Lee; Sang Cheol Seong; Myung Chul Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-01       Impact factor: 4.342

10.  Tibial internal rotation is affected by lateral laxity in cruciate-retaining total knee arthroplasty: an intraoperative kinematic study using a navigation system and offset-type tensor.

Authors:  Tokio Matsuzaki; Tomoyuki Matsumoto; Seiji Kubo; Hirotsugu Muratsu; Takehiko Matsushita; Yohei Kawakami; Kazunari Ishida; Shinya Oka; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-15       Impact factor: 4.342

View more
  9 in total

1.  Different intraoperative kinematics, stability, and range of motion between cruciate-substituting ultracongruent and posterior-stabilized total knee arthroplasty.

Authors:  Hagen Fritzsche; Franziska Beyer; Anne Postler; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-01-16       Impact factor: 4.342

Review 2.  Cruciate retaining and cruciate substituting ultra-congruent insert.

Authors:  Luca Mazzucchelli; Davide Deledda; Federica Rosso; Nicola Ratto; Matteo Bruzzone; Davide Edoardo Bonasia; Roberto Rossi
Journal:  Ann Transl Med       Date:  2016-01

Review 3.  Comparison of Functional Outcomes, Femoral Rollback and Sagittal Stability of Anterior-Stabilized Versus Posterior-Stabilized Total Knee Arthroplasty: A Systematic Review and Meta-analysis of Randomized Controlled Trials.

Authors:  Balgovind S Raja; Aditya K S Gowda; Sajid Ansari; Arghya Kundu Choudhury; Roop Bhushan Kalia
Journal:  Indian J Orthop       Date:  2021-08-23       Impact factor: 1.033

4.  Total knee arthroplasty using ultra-congruent inserts can provide similar stability and function compared with cruciate-retaining total knee arthroplasty.

Authors:  Eun-Kyoo Song; Hong-An Lim; Sang-Don Joo; Sung-Kyu Kim; Keun-Bae Lee; Jong-Keun Seon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

5.  No difference in range of motion between ultracongruent and posterior stabilized design in total knee arthroplasty: a randomized controlled trial.

Authors:  Jörg Lützner; Franziska Beyer; Julian Dexel; Hagen Fritzsche; Cornelia Lützner; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-22       Impact factor: 4.342

6.  Posterior-stabilized inserts are preferable to cruciate-substituting ultracongruent inserts due to more favourable kinematics and stability.

Authors:  Ji-Hoon Bae; Jung-Ro Yoon; Ju-Hyoung Sung; Young-Soo Shin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-02-19       Impact factor: 4.342

7.  Minimum twelve-year follow-up of fixed- vs mobile-bearing total knee arthroplasty: Double blinded randomized trial.

Authors:  Cameron J Killen; Michael P Murphy; William J Hopkinson; Melvyn A Harrington; William H Adams; Harold W Rees
Journal:  J Clin Orthop Trauma       Date:  2019-03-29

8.  Similar outcomes including maximum knee flexion between mobile bearing condylar-stabilised and fixed bearing posterior-stabilised prosthesis: a case control study.

Authors:  Jobe Shatrov; Elliot Sappey-Marinier; Moussa Kafelov; Stanislas Gunst; Cécile Batailler; Elvire Servien; Sébastien Lustig
Journal:  J Exp Orthop       Date:  2022-02-15

9.  Assessment of paradoxical anterior translation in a CR total knee prosthesis coupling dynamic RSA and FE techniques.

Authors:  Agostino Igor Mirulla; Laura Bragonzoni; Stefano Zaffagnini; Tommaso Ingrassia; Raffaele Zinno; Bernardo Innocenti
Journal:  J Exp Orthop       Date:  2021-07-10
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.