Literature DB >> 22875244

Penalized likelihood PET image reconstruction using patch-based edge-preserving regularization.

Guobao Wang1, Jinyi Qi.   

Abstract

Iterative image reconstruction for positron emission tomography (PET) can improve image quality by using spatial regularization that penalizes image intensity difference between neighboring pixels. The most commonly used quadratic penalty often oversmoothes edges and fine features in reconstructed images. Nonquadratic penalties can preserve edges but often introduce piece-wise constant blocky artifacts and the results are also sensitive to the hyper-parameter that controls the shape of the penalty function. This paper presents a patch-based regularization for iterative image reconstruction that uses neighborhood patches instead of individual pixels in computing the nonquadratic penalty. The new regularization is more robust than the conventional pixel-based regularization in differentiating sharp edges from random fluctuations due to noise. An optimization transfer algorithm is developed for the penalized maximum likelihood estimation. Each iteration of the algorithm can be implemented in three simple steps: an EM-like image update, an image smoothing and a pixel-by-pixel image fusion. Computer simulations show that the proposed patch-based regularization can achieve higher contrast recovery for small objects without increasing background variation compared with the quadratic regularization. The reconstruction is also more robust to the hyper-parameter than conventional pixel-based nonquadratic regularizations. The proposed regularization method has been applied to real 3-D PET data.

Entities:  

Mesh:

Year:  2012        PMID: 22875244      PMCID: PMC4080915          DOI: 10.1109/TMI.2012.2211378

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  18 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Stochastic relaxation, gibbs distributions, and the bayesian restoration of images.

Authors:  S Geman; D Geman
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1984-06       Impact factor: 6.226

3.  Reconstruction of 3D dynamic contrast-enhanced magnetic resonance imaging using nonlocal means.

Authors:  Ganesh Adluru; Tolga Tasdizen; Matthias C Schabel; Edward V R DiBella
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

Review 4.  Iterative reconstruction techniques in emission computed tomography.

Authors:  Jinyi Qi; Richard M Leahy
Journal:  Phys Med Biol       Date:  2006-07-12       Impact factor: 3.609

5.  A generalized Gaussian image model for edge-preserving MAP estimation.

Authors:  C Bouman; K Sauer
Journal:  IEEE Trans Image Process       Date:  1993       Impact factor: 10.856

6.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

7.  Convergence of EM image reconstruction algorithms with Gibbs smoothing.

Authors:  K Lange
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

8.  Nonlocal discrete regularization on weighted graphs: a framework for image and manifold processing.

Authors:  Abderrahim Elmoataz; Olivier Lezoray; Sébastien Bougleux
Journal:  IEEE Trans Image Process       Date:  2008-07       Impact factor: 10.856

9.  Sensitivity encoding reconstruction with nonlocal total variation regularization.

Authors:  Dong Liang; Haifeng Wang; Yuchou Chang; Leslie Ying
Journal:  Magn Reson Med       Date:  2010-12-16       Impact factor: 4.668

10.  Image restoration and reconstruction with a Bayesian approach.

Authors:  C M Kao; X Pan; C T Chen; W H Wong
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

View more
  43 in total

Review 1.  Local and Non-local Regularization Techniques in Emission (PET/SPECT) Tomographic Image Reconstruction Methods.

Authors:  Munir Ahmad; Tasawar Shahzad; Khalid Masood; Khalid Rashid; Muhammad Tanveer; Rabail Iqbal; Nasir Hussain; Abubakar Shahid
Journal:  J Digit Imaging       Date:  2016-06       Impact factor: 4.056

2.  Time-of-flight PET image reconstruction using origin ensembles.

Authors:  Christian Wülker; Arkadiusz Sitek; Sven Prevrhal
Journal:  Phys Med Biol       Date:  2015-02-10       Impact factor: 3.609

3.  Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT.

Authors:  Se Young Chun; Jeffrey A Fessler; Yuni K Dewaraja
Journal:  Phys Med Biol       Date:  2013-09-07       Impact factor: 3.609

4.  Joint solution for PET image segmentation, denoising, and partial volume correction.

Authors:  Ziyue Xu; Mingchen Gao; Georgios Z Papadakis; Brian Luna; Sanjay Jain; Daniel J Mollura; Ulas Bagci
Journal:  Med Image Anal       Date:  2018-03-28       Impact factor: 8.545

5.  PET Image Reconstruction Using Deep Image Prior.

Authors:  Kuang Gong; Ciprian Catana; Jinyi Qi; Quanzheng Li
Journal:  IEEE Trans Med Imaging       Date:  2018-12-19       Impact factor: 10.048

6.  Accelerated MRI using iterative non-local shrinkage.

Authors:  Yasir Q Mohsin; Gregory Ongie; Mathews Jacob
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

7.  Brain PET Poster Sessions PP01-M01 to PP02-N07.

Authors: 
Journal:  J Cereb Blood Flow Metab       Date:  2019-07       Impact factor: 6.200

8.  Model-Based Deep Learning PET Image Reconstruction Using Forward-Backward Splitting Expectation-Maximization.

Authors:  Abolfazl Mehranian; Andrew J Reader
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-06-23

Review 9.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

10.  Iterative Shrinkage Algorithm for Patch-Smoothness Regularized Medical Image Recovery.

Authors:  Yasir Q Mohsin; Gregory Ongie; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2015-01-30       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.