Literature DB >> 23927333

Megavoltage CT imaging quality improvement on TomoTherapy via tensor framelet.

Hao Gao1, X Sharon Qi, Yu Gao, Daniel A Low.   

Abstract

PURPOSE: This work is to investigate the feasibility of improving megavoltage imaging quality for TomoTherapy using a novel reconstruction technique based on tensor framelet, with either full-view or partial-view data.
METHODS: The reconstruction problem is formulated as a least-square L1-type optimization problem, with the tensor framelet for the image regularization, which is a generalization of L1, total variation, and wavelet. The high-order derivatives of the image are simultaneously regularized in L1 norm at multilevel along the x, y, and z directions. This convex formulation is efficiently solved using the Split Bregman method. In addition, a GPU-based parallel algorithm was developed to accelerate image reconstruction. The new method was compared with the filtered backprojection and the total variation based method in both phantom and patient studies with full or partial projection views.
RESULTS: The tensor framelet based method improved the image quality from the filtered backprojection and the total variation based method. The new method was robust when only 25% of the projection views were used. It required ∼2 min for the GPU-based solver to reconstruct a 40-slice 1 mm-resolution 350×350 3D image with 200 projection views per slice and 528 detection pixels per view.
CONCLUSIONS: The authors have developed a GPU-based tensor framelet reconstruction method with improved image quality for the megavoltage CT imaging on TomoTherapy with full or undersampled projection views. In particular, the phantom and patient studies suggest that the imaging quality enhancement via tensor framelet method is prominent for the low-dose imaging on TomoTherapy with up to a 75% projection view reduction.

Entities:  

Mesh:

Year:  2013        PMID: 23927333      PMCID: PMC3739831          DOI: 10.1118/1.4816303

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

Review 1.  Managing radiation use in medical imaging: a multifaceted challenge.

Authors:  Hedvig Hricak; David J Brenner; S James Adelstein; Donald P Frush; Eric J Hall; Roger W Howell; Cynthia H McCollough; Fred A Mettler; Mark S Pearce; Orhan H Suleiman; James H Thrall; Louis K Wagner
Journal:  Radiology       Date:  2010-12-16       Impact factor: 11.105

2.  Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit.

Authors:  Sanford L Meeks; Joseph F Harmon; Katja M Langen; Twyla R Willoughby; Thomas H Wagner; Patrick A Kupelian
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

3.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

Authors:  Martin J Murphy; James Balter; Stephen Balter; Jose A BenComo; Indra J Das; Steve B Jiang; C M Ma; Gustavo H Olivera; Raymond F Rodebaugh; Kenneth J Ruchala; Hiroki Shirato; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

Review 4.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

5.  Fast parallel algorithms for the x-ray transform and its adjoint.

Authors:  Hao Gao
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

6.  4D cone beam CT via spatiotemporal tensor framelet.

Authors:  Hao Gao; Ruijiang Li; Yuting Lin; Lei Xing
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

7.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy.

Authors:  T R Mackie; T Holmes; S Swerdloff; P Reckwerdt; J O Deasy; J Yang; B Paliwal; T Kinsella
Journal:  Med Phys       Date:  1993 Nov-Dec       Impact factor: 4.071

8.  High-dose MVCT image guidance for stereotactic body radiation therapy.

Authors:  David C Westerly; Tracey E Schefter; Brian D Kavanagh; Edward Chao; Dan Lucas; Ryan T Flynn; Moyed Miften
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

9.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM).

Authors:  Hao Gao; Hengyong Yu; Stanley Osher; Ge Wang
Journal:  Inverse Probl       Date:  2011-11-01       Impact factor: 2.407

10.  Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer.

Authors:  M J Zelefsky; Z Fuks; L Happersett; H J Lee; C C Ling; C M Burman; M Hunt; T Wolfe; E S Venkatraman; A Jackson; M Skwarchuk; S A Leibel
Journal:  Radiother Oncol       Date:  2000-06       Impact factor: 6.280

View more
  7 in total

1.  TICMR: Total Image Constrained Material Reconstruction via Nonlocal Total Variation Regularization for Spectral CT.

Authors:  Jiulong Liu; Huanjun Ding; Sabee Molloi; Xiaoqun Zhang; Hao Gao
Journal:  IEEE Trans Med Imaging       Date:  2016-07-07       Impact factor: 10.048

2.  Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy.

Authors:  Hao Gao; Yawei Zhang; Lei Ren; Fang-Fang Yin
Journal:  Med Phys       Date:  2017-12-11       Impact factor: 4.071

3.  Iterative reconstruction for CT perfusion with a prior-image induced hybrid nonlocal means regularization: Phantom studies.

Authors:  Bin Li; Qingwen Lyu; Jianhua Ma; Jing Wang
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

4.  A high-resolution photon-counting breast CT system with tensor-framelet based iterative image reconstruction for radiation dose reduction.

Authors:  Huanjun Ding; Hao Gao; Bo Zhao; Hyo-Min Cho; Sabee Molloi
Journal:  Phys Med Biol       Date:  2014-09-17       Impact factor: 3.609

5.  Technical Note: Iterative megavoltage CT (MVCT) reconstruction using block-matching 3D-transform (BM3D) regularization.

Authors:  Qihui Lyu; Chunlin Yang; Hao Gao; Yi Xue; Daniel O'Connor; Tianye Niu; Ke Sheng
Journal:  Med Phys       Date:  2018-04-30       Impact factor: 4.071

6.  Improved contrast and noise of megavoltage computed tomography (MVCT) through cycle-consistent generative machine learning.

Authors:  Luciano Vinas; Jessica Scholey; Martina Descovich; Vasant Kearney; Atchar Sudhyadhom
Journal:  Med Phys       Date:  2020-12-27       Impact factor: 4.071

7.  Tensor framelet based iterative image reconstruction algorithm for low-dose multislice helical CT.

Authors:  Haewon Nam; Minghao Guo; Hengyong Yu; Keumsil Lee; Ruijiang Li; Bin Han; Lei Xing; Rena Lee; Hao Gao
Journal:  PLoS One       Date:  2019-01-11       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.