A high-resolution photon-counting breast CT system with tensor-framelet based iterative image reconstruction for radiation dose reduction.

Huanjun Ding1, Hao Gao, Bo Zhao, Hyo-Min Cho, Sabee Molloi.   

Abstract

Both computer simulations and experimental phantom studies were carried out to investigate the radiation dose reduction with tensor framelet based iterative image reconstruction (TFIR) for a dedicated high-resolution spectral breast computed tomography (CT) based on a silicon strip photon-counting detector. The simulation was performed with a 10 cm-diameter water phantom including three contrast materials (polyethylene, 8 mg ml(-1) iodine and B-100 bone-equivalent plastic). In the experimental study, the data were acquired with a 1.3 cm-diameter polymethylmethacrylate (PMMA) phantom containing iodine in three concentrations (8, 16 and 32 mg ml(-1)) at various radiation doses (1.2, 2.4 and 3.6 mGy) and then CT images were reconstructed using the filtered-back-projection (FBP) technique and the TFIR technique, respectively. The image quality between these two techniques was evaluated by the quantitative analysis on contrast-to-noise ratio (CNR) and spatial resolution that was evaluated using the task-based modulation transfer function (MTF). Both the simulation and experimental results indicated that the task-based MTF obtained from TFIR reconstruction with one-third of the radiation dose was comparable to that from the FBP reconstruction for low contrast target. For high contrast target, the TFIR was substantially superior to the FBP reconstruction in terms of spatial resolution. In addition, TFIR was able to achieve a factor of 1.6-1.8 increase in CNR, depending on the target contrast level. This study demonstrates that the TFIR can reduce the required radiation dose by a factor of two-thirds for a CT image reconstruction compared to the FBP technique. It achieves much better CNR and spatial resolution for high contrast target in addition to retaining similar spatial resolution for low contrast target. This TFIR technique has been implemented with a graphic processing unit system and it takes approximately 10 s to reconstruct a single-slice CT image, which can potentially be used in a future multi-slit multi-slice spiral CT system.

Entities:  

Mesh:

Year:  2014        PMID: 25230204      PMCID: PMC5219880          DOI: 10.1088/0031-9155/59/20/6005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

1.  Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment.

Authors:  J M Boone
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

2.  Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study.

Authors:  Hans Bornefalk; Mats Danielsson
Journal:  Phys Med Biol       Date:  2010-03-19       Impact factor: 3.609

3.  Computed tomography with energy-resolved detection: a feasibility study.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2008-02-19       Impact factor: 3.609

4.  Megavoltage CT imaging quality improvement on TomoTherapy via tensor framelet.

Authors:  Hao Gao; X Sharon Qi; Yu Gao; Daniel A Low
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

5.  Fast parallel algorithms for the x-ray transform and its adjoint.

Authors:  Hao Gao
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

6.  A methodology for image quality evaluation of advanced CT systems.

Authors:  Joshua M Wilson; Olav I Christianson; Samuel Richard; Ehsan Samei
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

7.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.

Authors:  R Gordon; R Bender; G T Herman
Journal:  J Theor Biol       Date:  1970-12       Impact factor: 2.691

8.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application.

Authors:  Polad M Shikhaliev; Shannon G Fritz
Journal:  Phys Med Biol       Date:  2011-03-02       Impact factor: 3.609

9.  Low-dose X-ray CT reconstruction via dictionary learning.

Authors:  Qiong Xu; Hengyong Yu; Xuanqin Mou; Lei Zhang; Jiang Hsieh; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2012-04-20       Impact factor: 10.048

10.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM).

Authors:  Hao Gao; Hengyong Yu; Stanley Osher; Ge Wang
Journal:  Inverse Probl       Date:  2011-11-01       Impact factor: 2.407

View more
  3 in total

1.  TICMR: Total Image Constrained Material Reconstruction via Nonlocal Total Variation Regularization for Spectral CT.

Authors:  Jiulong Liu; Huanjun Ding; Sabee Molloi; Xiaoqun Zhang; Hao Gao
Journal:  IEEE Trans Med Imaging       Date:  2016-07-07       Impact factor: 10.048

2.  A Spectral CT Method to Directly Estimate Basis Material Maps From Experimental Photon-Counting Data.

Authors:  Taly Gilat Schmidt; Rina Foygel Barber; Emil Y Sidky
Journal:  IEEE Trans Med Imaging       Date:  2017-04-24       Impact factor: 10.048

3.  Multi-contrast brain magnetic resonance image super-resolution using the local weight similarity.

Authors:  Hong Zheng; Xiaobo Qu; Zhengjian Bai; Yunsong Liu; Di Guo; Jiyang Dong; Xi Peng; Zhong Chen
Journal:  BMC Med Imaging       Date:  2017-01-17       Impact factor: 1.930

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.