Literature DB >> 23127087

4D cone beam CT via spatiotemporal tensor framelet.

Hao Gao, Ruijiang Li, Yuting Lin, Lei Xing.   

Abstract

PURPOSE: On-board 4D cone beam CT (4DCBCT) offers respiratory phase-resolved volumetric imaging, and improves the accuracy of target localization in image guided radiation therapy. However, the clinical utility of this technique has been greatly impeded by its degraded image quality, prolonged imaging time, and increased imaging dose. The purpose of this letter is to develop a novel iterative 4DCBCT reconstruction method for improved image quality, increased imaging speed, and reduced imaging dose.
METHODS: The essence of this work is to introduce the spatiotemporal tensor framelet (STF), a high-dimensional tensor generalization of the 1D framelet for 4DCBCT, to effectively take into account of highly correlated and redundant features of the patient anatomy during respiration, in a multilevel fashion with multibasis sparsifying transform. The STF-based algorithm is implemented on a GPU platform for improved computational efficiency. To evaluate the method, 4DCBCT full-fan scans were acquired within 30 s, with a gantry rotation of 200°; STF is also compared with a state-of-art reconstruction method via spatiotemporal total variation regularization.
RESULTS: Both the simulation and experimental results demonstrate that STF-based reconstruction achieved superior image quality. The reconstruction of 20 respiratory phases took less than 10 min on an NVIDIA Tesla C2070 GPU card. The STF codes are available at https://sites.google.com/site/spatiotemporaltensorframelet.
CONCLUSIONS: By effectively utilizing the spatiotemporal coherence of the patient anatomy among different respiratory phases in a multilevel fashion with multibasis sparsifying transform, the proposed STF method potentially enables fast and low-dose 4DCBCT with improved image quality.

Entities:  

Mesh:

Year:  2012        PMID: 23127087      PMCID: PMC3494730          DOI: 10.1118/1.4762288

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Iterative 4D cardiac micro-CT image reconstruction using an adaptive spatio-temporal sparsity prior.

Authors:  Ludwig Ritschl; Stefan Sawall; Michael Knaup; Andreas Hess; Marc Kachelriess
Journal:  Phys Med Biol       Date:  2012-03-05       Impact factor: 3.609

2.  4D computed tomography reconstruction from few-projection data via temporal non-local regularization.

Authors:  Xun Jia; Yifei Lou; Bin Dong; Zhen Tian; Steve Jiang
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

3.  Respiratory correlated cone beam CT.

Authors:  Jan-Jakob Sonke; Lambert Zijp; Peter Remeijer; Marcel van Herk
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

Review 4.  Overview of image-guided radiation therapy.

Authors:  Lei Xing; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Tian-Fang Li; Gwe-Ya Kim; Gary Luxton; Albert Koong
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

5.  Linac-integrated 4D cone beam CT: first experimental results.

Authors:  Lars Dietrich; Siri Jetter; Thomas Tücking; Simeon Nill; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2006-05-24       Impact factor: 3.609

6.  Enhanced 4D cone-beam CT with inter-phase motion model.

Authors:  Tianfang Li; Albert Koong; Lei Xing
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

7.  Fast parallel algorithms for the x-ray transform and its adjoint.

Authors:  Hao Gao
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

8.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM).

Authors:  Hao Gao; Hengyong Yu; Stanley Osher; Ge Wang
Journal:  Inverse Probl       Date:  2011-11-01       Impact factor: 2.407

9.  Robust principal component analysis-based four-dimensional computed tomography.

Authors:  Hao Gao; Jian-Feng Cai; Zuowei Shen; Hongkai Zhao
Journal:  Phys Med Biol       Date:  2011-05-04       Impact factor: 3.609

10.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

View more
  20 in total

1.  TICMR: Total Image Constrained Material Reconstruction via Nonlocal Total Variation Regularization for Spectral CT.

Authors:  Jiulong Liu; Huanjun Ding; Sabee Molloi; Xiaoqun Zhang; Hao Gao
Journal:  IEEE Trans Med Imaging       Date:  2016-07-07       Impact factor: 10.048

2.  Sequentially reweighted TV minimization for CT metal artifact reduction.

Authors:  Xiaomeng Zhang; Lei Xing
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models.

Authors:  S Dhou; M Hurwitz; P Mishra; W Cai; J Rottmann; R Li; C Williams; M Wagar; R Berbeco; D Ionascu; J H Lewis
Journal:  Phys Med Biol       Date:  2015-04-23       Impact factor: 3.609

4.  A method for volumetric imaging in radiotherapy using single x-ray projection.

Authors:  Yuan Xu; Hao Yan; Luo Ouyang; Jing Wang; Linghong Zhou; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

5.  Megavoltage CT imaging quality improvement on TomoTherapy via tensor framelet.

Authors:  Hao Gao; X Sharon Qi; Yu Gao; Daniel A Low
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

6.  First study of on-treatment volumetric imaging during respiratory gated VMAT.

Authors:  Kihwan Choi; Lei Xing; Albert Koong; Ruijiang Li
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

7.  Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy.

Authors:  Hao Gao; Yawei Zhang; Lei Ren; Fang-Fang Yin
Journal:  Med Phys       Date:  2017-12-11       Impact factor: 4.071

8.  Accelerating dynamic magnetic resonance imaging (MRI) for lung tumor tracking based on low-rank decomposition in the spatial-temporal domain: a feasibility study based on simulation and preliminary prospective undersampled MRI.

Authors:  Manoj Sarma; Peng Hu; Stanislas Rapacchi; Daniel Ennis; Albert Thomas; Percy Lee; Patrick Kupelian; Ke Sheng
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-01-09       Impact factor: 7.038

9.  A high-resolution photon-counting breast CT system with tensor-framelet based iterative image reconstruction for radiation dose reduction.

Authors:  Huanjun Ding; Hao Gao; Bo Zhao; Hyo-Min Cho; Sabee Molloi
Journal:  Phys Med Biol       Date:  2014-09-17       Impact factor: 3.609

10.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.