Literature DB >> 23884280

Gated SPECT evaluation of left ventricular function using a CZT camera and a fast low-dose clinical protocol: comparison to cardiac magnetic resonance imaging.

Assuero Giorgetti1, Pier Giorgio Masci, Gavino Marras, Yasmine K Rustamova, Alessia Gimelli, Dario Genovesi, Massimo Lombardi, Paolo Marzullo.   

Abstract

PURPOSE: CZT technology allows ultrafast low-dose myocardial scintigraphy but its accuracy in assessing left ventricular function is still to be defined.
METHODS: The study group comprised 55 patients (23 women, mean age 63 ± 9 years) referred for myocardial perfusion scintigraphy. The patients were studied at rest using a CZT camera (Discovery NM530c; GE Healthcare) and a low-dose (99m)Tc-tetrofosmin clinical protocol (mean dose 264 ± 38 MBq). Gated SPECT imaging was performed as a 6-min list-mode acquisition, 15 min after radiotracer injection. Images were reformatted (8-frame to 16-frame) using Lister software on a Xeleris workstation (GE Healthcare) and then reconstructed with a dedicated iterative algorithm. Analysis was performed using Quantitative Gated SPECT (QGS) software. Within 2 weeks patients underwent cardiac magnetic resonance imaging (cMRI, 1.5-T unit CVi; GE Healthcare) using a 30-frame acquisition protocol and dedicated software for analysis (MASS 6.1; Medis).
RESULTS: The ventricular volumes obtained with 8-frame QGS showed excellent correlations with the cMRI volumes (end-diastolic volume (EDV), r = 0.90; end-systolic volume (ESV), r = 0.94; p < 0.001). However, QGS significantly underestimated the ventricular volumes (mean differences: EDV, -39.5 ± 29 mL; ESV, -15.4 ± 22 mL; p < 0.001). Similarly, the ventricular volumes obtained with 16-frame QGS showed an excellent correlations with the cMRI volumes (EDV, r = 0.92; ESV, r = 0.95; p < 0.001) but with significant underestimations (mean differences: EDV, -33.2 ± 26 mL; ESV, -17.9 ± 20 mL; p < 0.001). Despite significantly lower values (47.9 ± 16 % vs. 51.2 ± 15 %, p < 0.008), 8-frame QGS mean ejection fraction (EF) was closely correlated with the cMRI values (r = 0.84, p < 0.001). The mean EF with 16-frame QGS showed the best correlation with the cMRI values (r = 0.91, p < 0.001) and was similar to the mean cMRI value (49.6 ± 16 %, p not significant). Regional analysis showed a good correlation between both 8-frame and 16-frame QGS and cMRI wall motion score indexes (8-frame WMSI, r = 0.85; 16-frame WMSI, r = 0.89; p < 0.01).
CONCLUSION: Low-dose gated SPECT with a CZT camera provides ventricular volumes that correlate well with cMRI results despite significant underestimation in the measure values. EF estimation appeared to be more accurate with 16-frame reformatted images than with 8-frame images.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23884280     DOI: 10.1007/s00259-013-2505-9

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  20 in total

1.  Gated SPET quantification of small hearts: mathematical simulation and clinical application.

Authors:  K Nakajima; J Taki; T Higuchi; M Kawano; M Taniguchi; K Maruhashi; S Sakazume; N Tonami
Journal:  Eur J Nucl Med       Date:  2000-09

2.  High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results.

Authors:  Alessia Gimelli; Matteo Bottai; Dario Genovesi; Assuero Giorgetti; Fabio Di Martino; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-02       Impact factor: 9.236

Review 3.  Evaluation of left ventricular function using cardiac magnetic resonance imaging.

Authors:  Suchi Grover; Darryl P Leong; Joseph B Selvanayagam
Journal:  J Nucl Cardiol       Date:  2011-04       Impact factor: 5.952

4.  Nuclear cardiology at the door of a new era: better to save mSv or to reduce imaging time?

Authors:  Assuero Giorgetti; Dario Genovesi; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-12       Impact factor: 9.236

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Assessment of regional and global left ventricular function by reinjection T1-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with three-dimensional magnetic resonance imaging.

Authors:  E Tadamura; T Kudoh; M Motooka; M Inubushi; S Shirakawa; N Hattori; T Okada; T Matsuda; T Koshiji; K Nishimura; K Matsuda; J Konishi
Journal:  J Am Coll Cardiol       Date:  1999-03-15       Impact factor: 24.094

Review 7.  Cardiac dedicated ultrafast SPECT cameras: new designs and clinical implications.

Authors:  Ernest V Garcia; Tracy L Faber; Fabio P Esteves
Journal:  J Nucl Med       Date:  2011-01-13       Impact factor: 10.057

8.  Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations.

Authors:  K E Hammermeister; T A DeRouen; H T Dodge
Journal:  Circulation       Date:  1979-03       Impact factor: 29.690

9.  Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs.

Authors:  K Nakajima; T Higuchi; J Taki; M Kawano; N Tonami
Journal:  J Nucl Med       Date:  2001-10       Impact factor: 10.057

10.  Effect of sex, age, and weight on ejection fraction and end-systolic volume reference limits in gated myocardial perfusion SPECT.

Authors:  Richard A Peace; Philip C Adams; Jim J Lloyd
Journal:  J Nucl Cardiol       Date:  2008 Jan-Feb       Impact factor: 5.952

View more
  24 in total

1.  The time for radionuclide ventriculography resurrection is coming.

Authors:  Raffaele Giubbini; Elisa Milan
Journal:  J Nucl Cardiol       Date:  2015-08-08       Impact factor: 5.952

2.  Assessment of left ventricular mechanical dyssynchrony in coronary artery disease.

Authors:  Chetan D Patel; Anirban Mukherjee
Journal:  J Nucl Cardiol       Date:  2015-09-11       Impact factor: 5.952

3.  Left ventricular eccentricity index measured with SPECT myocardial perfusion imaging: An additional parameter of adverse cardiac remodeling.

Authors:  Alessia Gimelli; Riccardo Liga; Alberto Clemente; Gavino Marras; Annette Kusch; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2017-01-12       Impact factor: 5.952

4.  Influence of cardiac stress protocol on myocardial perfusion imaging accuracy: The role of exercise level on the evaluation of ischemic burden.

Authors:  Alessia Gimelli; Riccardo Liga; Emilio Maria Pasanisi; Mirta Casagranda; Michele Coceani; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2015-03-27       Impact factor: 5.952

5.  CZT camera: moving beyond classical CAD detection?

Authors:  Thomas Hellmut Schindler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-06       Impact factor: 9.236

6.  Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition.

Authors:  Loïc Djaileb; Benjamin Dubois; Nicolas de Leiris; Julien Leenhardt; Marjorie Canu; Olivier Phan Sy; Adrien Carabelli; Bastien Boussat; Laurent Dumas; Alexis Broisat; Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi; Gilles Barone-Rochette; Laurent M Riou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-18       Impact factor: 9.236

7.  Detection of ischemia with early myocardial perfusion imaging: You see more if you watch before.

Authors:  Riccardo Liga; Alessia Gimelli
Journal:  J Nucl Cardiol       Date:  2016-04-13       Impact factor: 5.952

8.  Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure.

Authors:  Dayong Wu; Zongyao Zhang; Rongzheng Ma; Feng Guo; Lei Wang; Wei Fang
Journal:  J Nucl Cardiol       Date:  2017-06-16       Impact factor: 5.952

9.  Real-time gated-SPECT myocardial perfusion imaging with CZT detectors: A promising tool for monitoring left ventricular function.

Authors:  Roberta Assante; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2018-03-15       Impact factor: 5.952

10.  Relationship between myocardial perfusion abnormalities and contractile impairment in anginal patients.

Authors:  Alessia Gimelli; Riccardo Liga; Assuero Giorgetti; Mirta Casagranda; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2014-07-31       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.