Literature DB >> 28623525

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure.

Dayong Wu1,2, Zongyao Zhang1, Rongzheng Ma1, Feng Guo1, Lei Wang3, Wei Fang4.   

Abstract

AIM: The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF).
METHODS: Fifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting 99mTc-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and 18F-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually.
RESULTS: There was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT.
CONCLUSION: CZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.

Entities:  

Keywords:  CZT; SPECT; heart failure; left ventricular function; mechanical synchrony; myocardial scar

Year:  2017        PMID: 28623525     DOI: 10.1007/s12350-017-0952-6

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  31 in total

1.  Comparison of high efficiency CZT SPECT MPI to coronary angiography.

Authors:  W Lane Duvall; Joseph M Sweeny; Lori B Croft; Maya H Barghash; Nitin K Kulkarni; Krista A Guma; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2011-06-03       Impact factor: 5.952

2.  Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography.

Authors:  W Lane Duvall; Joseph M Sweeny; Lori B Croft; Eric Ginsberg; Krista A Guma; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2011-12-07       Impact factor: 5.952

3.  Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology.

Authors:  Kjell Erlandsson; Krzysztof Kacperski; Dean van Gramberg; Brian F Hutton
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

4.  ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging).

Authors:  Francis J Klocke; Michael G Baird; Beverly H Lorell; Timothy M Bateman; Joseph V Messer; Daniel S Berman; Patrick T O'Gara; Blase A Carabello; Richard O Russell; Manuel D Cerqueira; Martin G St John Sutton; Anthony N DeMaria; James E Udelson; J Ward Kennedy; Mario S Verani; Kim Allan Williams; Elliott M Antman; Sidney C Smith; Joseph S Alpert; Gabriel Gregoratos; Jeffrey L Anderson; Loren F Hiratzka; David P Faxon; Sharon Ann Hunt; Valentin Fuster; Alice K Jacobs; Raymond J Gibbons; Richard O Russell
Journal:  Circulation       Date:  2003-09-16       Impact factor: 29.690

5.  Comparison of myocardial perfusion imaging using thallium-201 between a new cadmium-zinc-telluride cardiac camera and a conventional SPECT camera.

Authors:  Bernard Songy; David Lussato; Mohamed Guernou; Mathieu Queneau; Ricardo Geronazzo
Journal:  Clin Nucl Med       Date:  2011-09       Impact factor: 7.794

6.  Absolute quantification of left ventricular global and regional function at nuclear MPI using ultrafast CZT SPECT: initial validation versus cardiac MR.

Authors:  Hubert Cochet; Eric Bullier; Edouard Gerbaud; Muriel Durieux; Yann Godbert; Mathieu Lederlin; Pierre Coste; Jean-Louis Barat; François Laurent; Michel Montaudon
Journal:  J Nucl Med       Date:  2013-02-05       Impact factor: 10.057

7.  Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: phantom study and clinical validation vs cardiac magnetic resonance.

Authors:  Alban Bailliez; Tanguy Blaire; Frédéric Mouquet; R Legghe; B Etienne; Damien Legallois; Denis Agostini; Alain Manrique
Journal:  J Nucl Cardiol       Date:  2014-05-09       Impact factor: 5.952

Review 8.  Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).

Authors:  Denis Agostini; Pierre-Yves Marie; Simona Ben-Haim; François Rouzet; Bernard Songy; Alessandro Giordano; Alessia Gimelli; Fabien Hyafil; Roberto Sciagrà; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-19       Impact factor: 9.236

9.  Impact of coronary revascularization vs medical therapy on ischemia among stable patients with or suspected coronary artery disease undergoing serial myocardial perfusion scintigraphy.

Authors:  Francesco Nudi; Natale Di Belardino; Francesco Versaci; Annamaria Pinto; Enrica Procaccini; Giandomenico Neri; Maurizio Vetere; Giacomo Frati; Mariangela Peruzzi; Orazio Schillaci; Achille Gaspardone; Fabrizio Tomai; Giuseppe Biondi-Zoccai
Journal:  J Nucl Cardiol       Date:  2016-05-26       Impact factor: 5.952

10.  Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images.

Authors:  Laetitia Imbert; Sylvain Poussier; Philippe R Franken; Bernard Songy; Antoine Verger; Olivier Morel; Didier Wolf; Alain Noel; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Med       Date:  2012-11-08       Impact factor: 10.057

View more
  2 in total

1.  Importance of patient positioning in left ventricular function assessment.

Authors:  Gustavo Daquarti; Alejandro Meretta; Osvaldo Masoli
Journal:  J Nucl Cardiol       Date:  2017-07-28       Impact factor: 5.952

2.  Dedicated cardiac CZT SPECT is steadily moving to achieve its destiny.

Authors:  Doumit Daou
Journal:  J Nucl Cardiol       Date:  2017-07-25       Impact factor: 5.952

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.