Literature DB >> 2387937

Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography.

J G Dumesnil1, G N Honos, M Lemieux, J Beauchemin.   

Abstract

Doppler echocardiographic evaluation of aortic valve prostheses is based on the use of variables heretofore validated mostly for native valves. Accordingly, this study examined the validity and relative usefulness of the Doppler valve gradient and area measurements in 31 patients (mean age 69 +/- 10 years) 20 +/- 4 months after implantation of a given type of aortic bioprosthesis ranging in size from 19 to 29 mm. Valve area data obtained with both the standard and simplified continuity equations were compared with known in vitro prosthetic valve area measurements and an excellent correlation was obtained between the standard and simplified continuity equations (r = 0.98, SEE +/- 0.07 cm2, p less than 0.0005) and between in vivo and known in vitro prosthetic valve areas (r = 0.86, SEE +/- 0.16 cm2, p less than 0.0005). Peak gradient ranged from 10.8 to 75.0 mm Hg (mean 35 +/- 16) and mean gradient from 7.6 to 43.7 mm Hg (mean 20.5 +/- 9.5). The correlations between prosthetic valve gradient and in vivo area were r = -0.53, SEE +/- 14 mm Hg and r = -0.49, SEE +/- 8.63 mm Hg for peak and mean gradient, respectively. These relations were improved by indexing valve area by body surface area. The best correlations were obtained between indexed valve area and a quadratic function of the gradient (r = -0.72, SEE +/- 11.72 mm Hg and r = -0.70, SEE +/- 7.28 mm Hg for peak and mean gradient, respectively), reflecting a curvilinear relation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2387937     DOI: 10.1016/0735-1097(90)90355-s

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  25 in total

1.  [Hemodynamic evaluations of patients with small aortic annulus with St. Jude Medical prosthetic heart valve].

Authors:  T Shimabukuro; Y Takeuchi; A Gomi; H Nakatani; Y Suda; K Kono; N Nagano
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-12

Review 2.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

3.  Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

4.  The Quebec Heart Institute: 50 years of excellence in cardiology.

Authors:  Gilles R Dagenais; François Philippon; Jean-Pierre Després; Jean G Dumesnil; Paul Cartier; Peter M Bogaty; Michel Lemieux; André Moisan
Journal:  Can J Cardiol       Date:  2007-10       Impact factor: 5.223

Review 5.  Prosthesis-patient mismatch: an update.

Authors:  Jean G Dumesnil; Philippe Pibarot
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

6.  Echocardiographic assessment of artificial heart valves: British Society of Echocardiography position paper.

Authors:  J Chambers; A Fraser; P Lawford; P Nihoyannopoulos; I Simpson
Journal:  Br Heart J       Date:  1994-04

7.  Stentless bioprostheses have ideal haemodynamics, even in the small aortic root.

Authors:  L H Baur; Y Houdas; K H Peels; J Braun; B van Straten; A Prat; A P Kappetein; M Wolters-Geldoff; E E van der Wall; A V Bruschke; H A Huysmans
Journal:  Int J Card Imaging       Date:  2000-10

Review 8.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

9.  Ejection fraction-velocity ratio for the assessment of aortic bioprosthetic valves in patients with systolic dysfunction.

Authors:  P Cattaneo; P Marchetti; M Baravelli; A Rossi; G Mariscalco; S Ghiringhelli; C Anzà
Journal:  Can J Cardiol       Date:  2009-03       Impact factor: 5.223

Review 10.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.