Literature DB >> 27687067

Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Abdellaziz Dahou1, Haïfa Mahjoub1, Philippe Pibarot2.   

Abstract

OPINION STATEMENT: Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of a normally functioning prosthesis is too small in relation to the patient's body size, resulting in abnormally high postoperative gradients. PPM is frequent following aortic valve replacement (AVR), and it is associated with increased risk of morbidity and mortality proportionally to its severity. Differential diagnosis between PPM and prosthetic valve stenosis is made by comparing the measured valve effective orifice area, by assessing the changes in valve area and gradient during follow-up and by evaluating leaflet morphology and mobility. Preventive strategies to avoid or minimize PPM should be implemented especially in the patients who are at high risk for severe PPM and in those who have vulnerability factors to PPM. Transcatheter AVR may be superior to surgical AVR for the prevention of PPM and associated adverse cardiac events, particularly in the subset of patients with a small (<21 mm) aortic annulus. In this article, we discuss the most updated data regarding the diagnosis, clinical impact, and prevention of PPM after AVR.

Entities:  

Keywords:  Aortic valve replacement; Doppler echocardiography; Prosthesis-patient mismatch; Prosthetic heart valves; Transcatheter aortic valve replacement

Year:  2016        PMID: 27687067     DOI: 10.1007/s11936-016-0488-0

Source DB:  PubMed          Journal:  Curr Treat Options Cardiovasc Med        ISSN: 1092-8464


  79 in total

1.  Usefulness of the indexed effective orifice area at rest in predicting an increase in gradient during maximum exercise in patients with a bioprosthesis in the aortic valve position.

Authors:  P Pibarot; J G Dumesnil; J Jobin; M Lemieux; G Honos; L G Durand
Journal:  Am J Cardiol       Date:  1999-02-15       Impact factor: 2.778

2.  Impact of aortic stenosis severity and its interaction with prosthesis-patient mismatch on operative mortality following aortic valve replacement.

Authors:  Nicolas Girerd; Patrick Mathieu; Jean G Dumesnil; Julien Magne; Eric Charbonneau; François Dagenais; Eric Dumont; Pierre Voisine; Richard Baillot; Philippe Pibarot
Journal:  J Heart Valve Dis       Date:  2012-03

3.  Long-term durability of bioprosthetic aortic valves: implications from 12,569 implants.

Authors:  Douglas R Johnston; Edward G Soltesz; Nakul Vakil; Jeevanantham Rajeswaran; Eric E Roselli; Joseph F Sabik; Nicholas G Smedira; Lars G Svensson; Bruce W Lytle; Eugene H Blackstone
Journal:  Ann Thorac Surg       Date:  2015-02-04       Impact factor: 4.330

4.  Impact of prosthesis-patient mismatch on the regression of secondary mitral regurgitation after isolated aortic valve replacement with a bioprosthetic valve in patients with severe aortic stenosis.

Authors:  Emiliano Angeloni; Giovanni Melina; Philippe Pibarot; Umberto Benedetto; Simone Refice; Giuseppino M Ciavarella; Antonino Roscitano; Riccardo Sinatra; John R Pepper
Journal:  Circ Cardiovasc Imaging       Date:  2011-12-02       Impact factor: 7.792

5.  Flow acceleration time and ratio of acceleration time to ejection time for prosthetic aortic valve function.

Authors:  Sagit Ben Zekry; Robert M Saad; Mehmet Ozkan; Maie S Al Shahid; Mauro Pepi; Manuela Muratori; Jiaqiong Xu; Stephen H Little; William A Zoghbi
Journal:  JACC Cardiovasc Imaging       Date:  2011-11

6.  Patient and procedure selection for the prevention of prosthesis-patient mismatch following aortic valve replacement.

Authors:  Philippe Pibarot; Marie-Annick Clavel; Abdellaziz Dahou
Journal:  EuroIntervention       Date:  2015-09       Impact factor: 6.534

Review 7.  Is patient-prosthesis mismatch an independent risk factor for early and mid-term overall mortality in adult patients undergoing aortic valve replacement?

Authors:  Stefano Urso; Rafael Sadaba; Gonzalo Aldamiz-Echevarria
Journal:  Interact Cardiovasc Thorac Surg       Date:  2009-06-04

8.  Acquired von Willebrand syndrome in aortic stenosis.

Authors:  André Vincentelli; Sophie Susen; Thierry Le Tourneau; Isabelle Six; Olivier Fabre; Francis Juthier; Anne Bauters; Christophe Decoene; Jenny Goudemand; Alain Prat; Brigitte Jude
Journal:  N Engl J Med       Date:  2003-07-24       Impact factor: 91.245

9.  Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.

Authors:  Danny Dvir; John G Webb; Sabine Bleiziffer; Miralem Pasic; Ron Waksman; Susheel Kodali; Marco Barbanti; Azeem Latib; Ulrich Schaefer; Josep Rodés-Cabau; Hendrik Treede; Nicolo Piazza; David Hildick-Smith; Dominique Himbert; Thomas Walther; Christian Hengstenberg; Henrik Nissen; Raffi Bekeredjian; Patrizia Presbitero; Enrico Ferrari; Amit Segev; Arend de Weger; Stephan Windecker; Neil E Moat; Massimo Napodano; Manuel Wilbring; Alfredo G Cerillo; Stephen Brecker; Didier Tchetche; Thierry Lefèvre; Federico De Marco; Claudia Fiorina; Anna Sonia Petronio; Rui C Teles; Luca Testa; Jean-Claude Laborde; Martin B Leon; Ran Kornowski
Journal:  JAMA       Date:  2014-07       Impact factor: 56.272

Review 10.  Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging.

Authors:  Patrizio Lancellotti; Philippe Pibarot; John Chambers; Thor Edvardsen; Victoria Delgado; Raluca Dulgheru; Mauro Pepi; Bernard Cosyns; Mark R Dweck; Madalina Garbi; Julien Magne; Koen Nieman; Raphael Rosenhek; Anne Bernard; Jorge Lowenstein; Marcelo Luiz Campos Vieira; Arnaldo Rabischoffsky; Rodrigo Hernández Vyhmeister; Xiao Zhou; Yun Zhang; Jose-Luis Zamorano; Gilbert Habib
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2016-05-03       Impact factor: 6.875

View more
  5 in total

Review 1.  Prosthesis-patient mismatch - what cardiac anesthesiologists need to know?

Authors:  Kathirvel Subramaniam; Soheyla Nazarnia
Journal:  Ann Card Anaesth       Date:  2017 Apr-Jun

2.  Postoperative morbidity and mortality from aortic valve replacements in 25 cases in Senegal.

Authors:  Momar Sokhna Diop; Papa Salmane Ba; Abdoulaye Boubou Aw; Papa Amath Diagne; Ndeye Fatou Sow; Papa Ousmane Ba; Amadou Gabriel Ciss
Journal:  Pan Afr Med J       Date:  2020-06-23

Review 3.  Management of Failed Bioprosthetic Aortic Valves: Mitigating Complications and Optimizing Outcomes.

Authors:  Elizabeth L Norton; Alison F Ward; Adam Greenbaum; Kendra J Grubb
Journal:  J Interv Cardiol       Date:  2022-09-02       Impact factor: 1.776

4.  Comparing Clinical and Hemodynamic Parameters between the Two Aortic Valve Replacement in Patients with Severe Aortic Stenosis.

Authors:  Alireza Moaref; Khalil Zarrabi; Mani Hassanzadeh; Mahshid Fasihyan; Zahra Mehdipour Namdar; Amir Aslani
Journal:  J Cardiovasc Echogr       Date:  2022-08-17

5.  Determinants of Aortic Prosthesis Mismatch in a Brazilian Public Health System Hospital: Big Patients or Small Prosthesis?

Authors:  Maria Estefania Otto; Fernando Antibas Atik; Marcelo do Nascimento Moreira; Luiz Carlos Madruga Ribeiro; Bianca Corrêa Rocha de Mello; Joyce Gomes Elias Lima; Maiara Sanchez Ribeiro; Ana Carolina Pereira Matos Domingues; Reyna Pinheiro Calzada; Armindo Jreige; Larissa Lucas Schloicka; Philippe Pibarot
Journal:  Arq Bras Cardiol       Date:  2020-01       Impact factor: 2.000

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.