[Hemodynamic evaluations of patients with small aortic annulus with St. Jude Medical prosthetic heart valve].

T Shimabukuro1, Y Takeuchi, A Gomi, H Nakatani, Y Suda, K Kono, N Nagano.   

Abstract

As the elderly population in Japan increases, senile degenerative aortic valvular disease also tends to increase. These patients often have a small aortic annulus. The problem of "valve-patient-mismatch" occurs when a small prosthesis is inserted into a patient with a small aortic annulus. To avoid annular enlargement after aortic valve replacement (AVR), we tried to use a small-sized St. Jude Medical (SJM) valve. From September 1988 through November 1996, 110 AVR were performed in our institution. In these cases, 30 underwent AVR with a small sized SJM valve (male < or = 21 mm, female < or = 19 mm). Dobutamine stress echocardiography was performed in 19 patients who had undergone AVR with a small-sized SJM valve. Surgical results were also compared between patients with small aortic annulus and those with normal-sized aortic annulus. Using Doppler echocardiography, pressure gradients (PG), cardiac index (CI), effective orifice area (EOA), and performance index (PI) were calculated at rest and during stress. The mean body surface area (BSA) of patient who had undergone AVR with SJM19A, 19HP and 21A was 1.40, 1.42 and 1.56 m2, respectively. With dobutamine stress, heart rates, PG and CI increased significantly. Mean and maximum PG of patients with 19HP (8.0 and 15.4 mmHg at rest, 12.9 and 28.0 mmHg under stress, respectively) and 21A (9.5 and 19.1 mmHg at rest, 16.5 and 35.3 mmHg under stress, respectively) were relatively low. EOA index (EOAI) of patient with 19HP showed the highest values mean 0.93 cm2/m2. PIs tended to be higher with HP models than with standard models. The tests were completed without significant side effects such as frequent ventricular arrhythmias. Among the cases with small aortic annulus, there were no operative deaths or hospital deaths. There were also no late deaths, episodes of hemorrhage or thrombosis. Conclusions. In our institution, AVR was performed safely without any aortic annular enlargement with a small aortic anulus in small BSA patients. Postoperative hemodynamic data obtained by echocardiography were satisfactory for all patients at rest and even during maximum dobutamine stress test.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10037837     DOI: 10.1007/bf03217917

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  29 in total

1.  Accuracy of dobutamine stress echocardiography in detecting coronary artery disease.

Authors:  P A Marcovitz; W F Armstrong
Journal:  Am J Cardiol       Date:  1992-05-15       Impact factor: 2.778

2.  Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography.

Authors:  J G Dumesnil; G N Honos; M Lemieux; J Beauchemin
Journal:  J Am Coll Cardiol       Date:  1990-09       Impact factor: 24.094

3.  Hypoplasia of the aortic root. The problem of aortic valve replacement.

Authors:  R Nicks; T Cartmill; L Bernstein
Journal:  Thorax       Date:  1970-05       Impact factor: 9.139

4.  Comparative study of the hydrodynamic function of the size 19mm and 21mm St. Jude Medical Hemodynamic Plus Bileaflet Heart valves.

Authors:  J Fisher
Journal:  J Heart Valve Dis       Date:  1994-01

5.  Aortic valve replacement in adult patients with small aortic annuli.

Authors:  T E David; D E Uden
Journal:  Ann Thorac Surg       Date:  1983-11       Impact factor: 4.330

6.  A new method for prosthetic valve replacement in congenital aortic stenosis associated with hypoplasia of the aortic valve ring.

Authors:  S Konno; Y Imai; Y Iida; M Nakajima; K Tatsuno
Journal:  J Thorac Cardiovasc Surg       Date:  1975-11       Impact factor: 5.209

7.  Ten-year experience with the St. Jude Medical valve for primary valve replacement.

Authors:  L S Czer; A Chaux; J M Matloff; M A DeRobertis; S A Nessim; D Scarlata; S S Khan; R M Kass; T P Tsai; C Blanche
Journal:  J Thorac Cardiovasc Surg       Date:  1990-07       Impact factor: 5.209

8.  Evaluation of the hemodynamic performance of small CarboMedics aortic prostheses using dobutamine-stress Doppler echocardiography.

Authors:  M B Izzat; I Birdi; P Wilde; A J Bryan; G D Angelini
Journal:  Ann Thorac Surg       Date:  1995-10       Impact factor: 4.330

9.  Eleven-year follow-up study of aortic or aortic-mitral anulus-enlarging procedure by Manouguian's technique.

Authors:  Y Kawachi; R Tominaga; K Tokunaga
Journal:  J Thorac Cardiovasc Surg       Date:  1992-11       Impact factor: 5.209

10.  Long term clinical results with 19 mm or 21 mm standard aortic St. Jude Medical prosthesis.

Authors:  J Hayashi; S Nakazawa; H Okazaki; H Ohzeki; A Saito; H Moro; K Yamamoto; S Eguchi
Journal:  J Heart Valve Dis       Date:  1994-09
View more
  1 in total

1.  Oblique aortic valve replacement and coronary artery bypass grafting for severely calcified narrow aortic root with unstable angina.

Authors:  T Ishida; K Nakano; A Gomi; H Nakatani; T Sato; N Saegusa
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.