Effect of thermal cycling on denture base and autopolymerizing reline resins.

Cíntia de Souza Silva1, Ana Lucia Machado, Carolina de Andrade Lima Chaves, Ana Cláudia Pavarina, Carlos Eduardo Vergani.   

Abstract

OBJECTIVE: This study evaluated the fracture toughness (FT) of denture base and autopolymerizing reline resins, with and without thermocycling (T).
MATERIAL AND METHODS: Specimens of each material (denture base acrylic resin - Lucitone 550 - L; autopolymerizing reline resins - Ufi Gel Hard-UH, Tokuyama Rebase II-TR, New Truliner-NT and Kooliner-K), were produced, notched and divided into two groups (n=10): CG (control group of autopolymerizing reline resins and L): FT tests were performed after polymerization; TG (thermocycled group): FT tests were performed after T (5°C and 55°C for 5,000 cycles).
RESULTS: Results (MPa.m1/2) were analyzed by two-way ANOVA and Tukey's test (p=0.05). L exhibited the highest FT mean values in both groups (CG - 2.33; TG - 2.17). For the CG groups, NT showed the highest FT (1.64) among the autopolymerizing reline resins, and K the lowest (1.04). After T, when the autopolymerizing reline resins were compared, a statistically significant difference in FT was found only between the NT (1.46) and TR (1.00).
CONCLUSIONS: Thermocycling increased the FT of K and did not influence the FT of L, UH, TR and NT.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23857648      PMCID: PMC3881901          DOI: 10.1590/1679-775720130061

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Poly (methyl methacrylate) (PMMA)-based polymers are the materials most commonly used for the construction of removable dentures due to their working characteristics, ease of manipulation, clinical serviceability and satisfactory aesthetics[9,20]. Another advantage offered by these polymers is the possibility of relining the denture intaglio surface to improve the fit to the supporting tissues due to changes that result from continued bone resorption. In this context, autopolymerizing reline resins can be an attractive alternative to heat-polymerized acrylic resins because they can be placed chair-side, are easier to apply, and no laboratory procedures are required[25]. In the oral cavity, the denture prostheses are usually under conditions of thermal variations due to the ingestion of hot and cold liquids[5,10,23]. Such thermal cycling in a wet environment may cause degradation of the denture polymers[1,17], and the heat stress may increase water sorption because of an extension of the distance between the polymer chains[1]. Absorbed water can act as a plasticizer and soften the denture, thus reducing the mechanical properties of the material[1,9]. Conversely, heating the acrylic resins may enhance further polymerization reactions[27]; consequently, an improvement in the mechanical properties can be expected[27]. Hence, the possible effect of thermal cycling on the mechanical properties of the acrylic resins must be considered since this factor may influence the performance of the relined removable prostheses. Among the desirable properties of denture base and autopolymerizing reline resins is the fracture toughness which measures the sensitivity of the material to the presence of sharp notches (crack initiation)[28] such as frenal and incisal notches in maxillary dentures where stress concentration may occur[8]. Denture fractures cause inconvenience, additional costs and social embarrassment to patients[8]. Fracture toughness can be measured by using a fracture mechanics approach[18] and may more accurately determine the likelihood of the fracture of denture polymers in clinical practice[16]. Although several studies have evaluated the fracture toughness of denture base acrylic resins[11,13,15,16,18,26,28], there is little information on the toughness of autopolymerizing reline resins[12]. In addition, the effect of thermal stresses on the toughness of denture base and autopolymerizing reline resins has not (to the authors' knowledge) been previously reported. The aim of this study was to evaluate the effect of thermocycling on the fracture toughness of one denture base and four autopolymerizing reline resins. The null hypotheses were that there would be no differences in the fracture toughness among the acrylic resins evaluated and that this property would not be affected by thermocycling.

MATERIAL AND METHODS

One denture base acrylic resin (Lucitone 550) and four autopolymerizing reline resins (Ufi Gel Hard, Tokuyama Rebase II, New Truliner and Kooliner) were evaluated in this study. The product codes, batch numbers, manufacturers, compositions, powder/liquid proportions and polymerization cycles of the materials evaluated are listed in Figure 1.
Figure 1

Materials used in this study

ProductCodeManufacturerPowder/ liquid ratioCompositionBatch numberPolymerization cycles
Lucitone 550LDentsply Indústria e Comércio Ltda., Petrópolis, RJ, Brazil2.1 g/1 mlPowder - PMMAP- 8760090 min at 73oC and then 100oC boiling water for 30 min
    Liquid - MMA and EDGMAL- 91434 
Ufi Gel HardUHVoco, Cuxhaven, Germany2.12 g/1.2 mLPowder - PEMA6317428.5 min at room temperature
    Liquid - 1,6-HDMA  
Tokuyama Rebase IITRTokuyama Dental Corp.,Tokyo, Japan2.1 g/1 mLPowder - PEMAUF 658865.5 min at room temperature
    Liquid - AAEM and 1,9-nonanediol dimethacrylate  
New TrulinerNTThe Bosworth Co., Skokie, IL, USA1.34 g/1 mLPowder - PEMA0310-52820 min at room temperature
    Liquid - IBMA and DBP  
KoolinerKGC America Inc, Alsip, IL, USA1.4 g/1 mLPowder - PEMA80505110 min at room temperature
    Liquid - IBMA  

PMMA, poly (methyl methacrylate); MMA, (methyl methacrylate); EDGMA, (ethylene glycol dimethacrylate); PEMA, poly (ethyl methacrylate); 1,6-HDMA, 1,6-hexanediol dimethacrylate; AAEM – 2-acetoacetoxy (ethyl) methacrylate; IBMA, isobutyl methacrylate; DBP, di-n-butyl phthalate

Materials used in this study PMMA, poly (methyl methacrylate); MMA, (methyl methacrylate); EDGMA, (ethylene glycol dimethacrylate); PEMA, poly (ethyl methacrylate); 1,6-HDMA, 1,6-hexanediol dimethacrylate; AAEM – 2-acetoacetoxy (ethyl) methacrylate; IBMA, isobutyl methacrylate; DBP, di-n-butyl phthalate Specimens from each material were produced using a stainless steel mold with a cavity (40 mm×8 mm×4 mm)[28]. To fabricate the Lucitone 550 specimens, initially, the silicone impression material was adapted inside the stainless steel mold. The silicone patterns were then removed from the mold, placed between two glass slides and invested in Type IV stone using a conventional dentureprocessing flask. After the stone had set, the flask was opened and the silicone patterns were removed to create the stone molds. The Lucitone 550 heatpolymerized resin was then manipulated, packed into the stone mold, and polymerized in a water bath following the manufacturer's instructions (Figure 1). Then the flasks were removed from the water bath and bench cooled to room temperature before the specimens were removed. After polymerization, the specimens were finished with 320-grit silicon carbide paper to remove irregularities; then the accuracy of the dimensions was verified with a caliper. The specimens were then stored in water at 37ºC for 48±2 hours[19]. To prepare the specimens of the autopolymerizing reline resins (UH, TR, NT and K), the stainless steel mold was placed on the center of a glass plate covered with an acetate sheet. The autopolymerizing reline resins were mixed according to the manufacturer's instructions, and placed into the mold spaces (40 mm×8 mm×4 mm). A second acetate sheet was placed on top of the resin and another glass plate was placed on top of the acetate sheet. Light pressure was applied to expel excess material from the mold, and the materials were polymerized according to the manufacturers' instructions (Figure 1). After polymerization, any excess material was removed using silicon carbide paper (320-grit), and the dimensions were verified with a caliper. For the fracture toughness measurements, the method used by Zappini, Kammann and Watcher[28] (2003) and Puri, et al.[26] (2008) was followed. The test requires a sharp-notched specimen loaded in a three-point bending configuration which is also known as the single edge-notched bend (SENB) method[28]. Thus, a 0.5-mm-wide notch, 3.0 mm in length, was machined in the center of each specimen and then sharpened using a razor blade to extend the notch another 0.1 to 0.2 mm[26]. The specimens of each material (n=20) were then divided into two groups: one control (CG) and one experimental (TG). For the UH, TR, NT and K autopolymerizing reline resins, the specimens were subjected to fracture toughness tests (GC group), or to the thermal cycling prior to the fracture toughness tests (TG group), within 30 min after polymerization. This time period was used since the patients will be wearing the relined denture bases soon after polymerization. For the L denture base material, the specimens were subjected to fracture toughness tests (GC group), or to the thermal cycling prior to the fracture toughness tests (TG group), after storage in distilled water at 37±1ºC for 48±2 h[19]. Thermal cycles were performed in a thermocycling machine (model MSCT-3, Marcelo Nucci - Me, São Carlos, SP, Brazil) and consisted of 5000 cycles at 5ºC and 55ºC with a 30-second dwell time[14]. Fracture toughness measurements were carried out in a universal testing machine (MTS 810, MTS Systems Corporation, eden Prairie, MN, USA) in a three-point bending configuration at a cross-head speed of 1 mm/min and a 32-mm specimen test span[26,28]. The toughness test was carried out in a water bath at 37±1ºC. The maximum stress intensity factor (KI,max) was calculated using the following formula[28]: KI,max =f Pmax/(B W), where Pmax is the maximum load, B is the specimen thickness, W is the specimen width, and f is a geometrical factor depending on the ratio (a/W. KI,max was expressed in MPa.m1/2. Data were analyzed using the two-way ANOVA and Tukey's tests (p=0.05). The software package used for statistical analysis was the SPSS version 16.0 for Windows (Chicago, IL, USA).

RESULTS

The two-way ANOVA on the fracture toughness revealed a significant effect of material (p<0.001) and material x thermocycling interaction (p<0.001). ANOVA did not detect any significant effect of the main factor thermocycling (p=0.122). Figure 2 shows the means and standard deviations for all materials and groups evaluated. For the control groups, the mean fracture toughness value of L denture base acrylic resin was significantly higher than the values of the autopolymerizing reline resins (p<0.001). Among the autopolymerizing reline resins, the NT material showed significantly higher (p<0.001) mean fracture toughness than the UH and TR which did not differ from each other (p=0.222). The K autopolymerizing reline resin exhibited the lowest fracture toughness mean value (p<0.001).
Figure 2

Means and standard deviations (SD) of fracture toughness KI,max (MPa.m1/2) for the materials and groups evaluated. CG – control group. TG – thermocycled group. For the CG, means that are significantly different (p<0.05) are indicated by different capital letters. For the TG, means that are significantly different (p<0.05) are indicated by different small letters. For each material, connected bar denotes no significant difference between the CG and TG groups (p<0.05)

Means and standard deviations (SD) of fracture toughness KI,max (MPa.m1/2) for the materials and groups evaluated. CG – control group. TG – thermocycled group. For the CG, means that are significantly different (p<0.05) are indicated by different capital letters. For the TG, means that are significantly different (p<0.05) are indicated by different small letters. For each material, connected bar denotes no significant difference between the CG and TG groups (p<0.05) For the thermocycled specimens, the denture base resin L showed a significantly higher mean than all autopolymerizing reline resins tested (p<0.001). There was no significant difference between the NT and UH autopolymerizing reline resins (p=0.821) which in turn was not significantly different from the K (p=0.242). The difference between the K and TR materials was also not significant (p=0.569). Figure 2 illustrates that the fracture toughness of the K material showed a significant increase after thermocycling (p=0.001). For the other materials evaluated (L, UH, TR and NT), thermocycling did not significantly affect the fracture toughness (p=0.439, p=0.910, p=1.000 and p=0.305, respectively).

DISCUSSION

Fracture toughness (the ability of a material to resist crack propagation,) is an important property for denture base and autopolymerizing reline resins, preventing or reducing the incidence of denture fracture, thus decreasing patient discomfort and unscheduled appointments for denture replacement or repair. The fracture toughness test was selected for this study because Zappini, Kammann and Watcher[28] (2003), who evaluated seven heatpolymerized denture base resins, showed that this test may be more suitable for predicting the clinical performance of dental biomaterials than the impact test which is influenced by loading conditions and specimen geometry. The results demonstrated that the Lucitone 550 denture base acrylic resin exhibited the highest values of fracture toughness, in both the control and thermocycled groups, when compared with the autopolymerizing reline resins. Thus, the null hypothesis that the fracture toughness of the denture base and the autopolymerizing reline resins would be similar was rejected. Other investigators have also found that heat-polymerized denture base acrylic resins have higher mechanical properties than autopolymerizing acrylic resins, such as the autopolymerizing reline resins evaluated[1,2,12,22]. This result has been attributed to the higher temperature and longer polymerization time used for processing the heat-polymerized acrylic resins which decreases their residual monomer content[7], and, consequently, improves their mechanical properties[27]. Mean toughness values for the Lucitone 550 were within the range reported in the literature for heat-polymerized denture base acrylic resins[12,26,28]. In the control group, results also showed that the fracture toughness mean values of the Ufi Gel Hard and Tokuyama Rebase II materials were significantly lower than the values of the New Truliner autopolymerizing reline resin. One possible explanation for these findings could be their composition. According to the manufacturers, the Ufi Gel Hard and Tokuyama Rebase II materials contain high concentrations of the cross-linking agents 1.6-HDMA and 1.9-nonanediol dimethacrylate, respectively. Resins that are dimethacrylate-based result in a highly crosslinked polymer structure after polymerization, which undergoes brittle fracture[4,21] due to the lack of molecular mobility and increased resistance against local plastic deformation. Resins composed primarily of monomethacrylates tend to produce lower crosslinking, and also lower strength values[21]. In this study, the Kooliner autopolymerizing reline resin is composed of the monofunctional monomer isobutyl methacrylate without a cross-linking agent which may account for the lower fracture toughness of this material. The higher level of residual monomer of the Kooliner[27] may also contribute to the findings since the unreacted monomer that remains within the polymerized material may compromise it's mechanical properties[24,27]. Although the Kooliner and New Truliner autopolymerizing reline resins have similar compositions, the fracture toughness of the New Truliner was significantly higher than the fracture toughness of the Kooliner. This result may be related to the plasticizer di-n-butyl phthalate (8%) contained in the liquid of the New Truliner[2,3] which provides flexibility to the material. It is likely that the crack propagated more slowly due to the ability of the New Truliner autopolymerizing reline resin to absorb energy through plastic deformation. Over time, denture base and autopolymerizing reline resins are routinely exposed to a wide range of temperatures in a wet environment[5,10,23], and therefore it is important to establish whether these changing oral temperatures affect their mechanical properties. Thus, it has been suggested that thermocycling should be part of the testing protocol for dental polymers. Thermocycling is an in vitro process where test materials are subjected to temperature extremes using water baths in an attempt to simulate conditions in the oral cavity. Hence, in this study, all materials were exposed to thermocycling (5,000×5ºC/55ºC) in a water bath before testing. The hypothesis that the fracture toughness of the acrylic resins evaluated would not be affected by thermocycling was only partially accepted. While the fracture toughness of the materials Lucitone 550, Ufi Gel Hard, Tokuyama Rebase II and New Truliner did not change, and a significant increase in fracture toughness was observed for the Kooliner autopolymerizing reline resin. The thermal cycling procedure involved not only temperature changes, but also immersion in water baths. As mentioned before, the Ufi Gel Hard and Tokuyama Rebase II materials contain high concentrations of cross-linking agents. The Lucitone 550 denture base resin also contains the cross-linking agent ethylene glycol dimethacrylate (EDGMA). It has been reported that cross-linkage provides a sufficient number of bridges between linear macromolecules to form a three-dimensional network and thus decreases water sorption of the acrylic resins[2,3]. It has also been observed that the plasticizer molecules such as di-n-butyl phthalate contained in the New Truliner autopolymerizing reline resin can fill microvoids and thereby exclude the uptake of water[2]. In part, these aspects may explain why the fracture toughness of the materials Lucitone 550, Ufi Gel Hard, Tokuyama Rebase II and New Truliner was not affected when they were immersed in water during thermal cycling. For the Kooliner autopolymerizing reline resin, results from this study also showed that thermocycling resulted in a significant increase in fracture toughness. During thermocycling, the hot water may have accelerated the uptake of water which resulted in the plasticization of the polymer and decreased the mechanical properties. Conversely, the hot water may also have accelerated the release of degradation products and unreacted monomer molecules[27], promoted further free-radical polymerization reactions and increased the degree of conversion[27]. Compared with the other materials evaluated, the Kooliner autopolymerizing reline resin presents significantly higher amount of available unreacted methacrylate units [27]. Moreover, Kooliner is a noncross-linked autopolymerizing reline resin which may have facilitated water sorption[2,3]. Absorbed water may act as a peculiar catalyst for the postpolymerization chemical reaction by increasing the probability of contact between groups that have not reacted to create chemical bonds[6]. Thus, it is likely that the release and post-polymerization phenomena were more extensive for this material and may have outweighed any plasticizing effect of the water. As a result, the fracture toughness of the Kooliner increased after thermocycling. Mimicking one of the in vivo degradation factors involved (such as the thermal stresses which denture polymers will be exposed to in the oral cavity) is useful to disclose its effect on the general degradation process. Thus, in this in vitro study, the materials were subjected only to thermocycling. Based on these findings, it is possible that variations in oral temperature will have an overall positive effect on the fracture toughness. However, it should be noted that clinical conditions differ from the in vitro setting; for this reason, these findings must be carefully interpreted. Clinically, denture base and autopolymerizing reline resins will also be subjected to masticatory stresses; therefore, the effect of cyclic loading on the fracture toughness of these materials requires further investigation.

CONCLUSIONS

Within the limitations of this in vitro study, the following conclusions were reached: 1. The Lucitone 550 denture base acrylic resin displayed the highest mean fracture toughness values in both the control and thermocycled groups. 2. Among the autopolymerizing reline resins tested, the New Truliner material exhibited higher mean fracture toughness value than the Ufi Gel Hard, Tokuyama Rebase II and Kooliner materials in the control group. After thermocycling, the New Truliner showed a higher mean fracture toughness value than the Tokuyama Rebase II, while the Ufi Gel Hard and Kooliner materials did not differ from each other. 3. Thermocycling did not adversely affect the fracture toughness of the materials evaluated since the values either did not change (as occurred for the Lucitone 550, Ufi Gel Hard, Tokuyama Rebase II and New Truliner materials) or increased significantly (as observed for the Kooliner autopolymerizing reline resin).
  25 in total

1.  Effect of microwave disinfection on mechanical properties of denture base acrylic resin.

Authors:  Ibrahim M Hamouda; Sabry A Ahmed
Journal:  J Mech Behav Biomed Mater       Date:  2010-05-11

2.  Strain analysis of maxillary complete denture with three-dimensional finite element method.

Authors:  Yi Y Cheng; Wai L Cheung; Tak W Chow
Journal:  J Prosthet Dent       Date:  2010-05       Impact factor: 3.426

3.  Effect of microwave postpolymerization treatment on residual monomer content and the flexural strength of autopolymerizing reline resin.

Authors:  Padmakar S Patil; Ramesh Chowdhary; Rashmi B Mandokar
Journal:  Indian J Dent Res       Date:  2009 Jul-Sep

4.  Relative fracture toughness of bis-acryl interim resin materials.

Authors:  Lisa A Knobloch; Ronald E Kerby; Teresa Pulido; William M Johnston
Journal:  J Prosthet Dent       Date:  2011-08       Impact factor: 3.426

5.  Influence of polymerization method, curing process, and length of time of storage in water on the residual methyl methacrylate content in dental acrylic resins.

Authors:  Gulsen Bayraktar; Bora Guvener; Canan Bural; Yagiz Uresin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2006-02       Impact factor: 3.368

6.  Effect of thermal cycling on microleakage between hard chairside relines and denture base acrylic resins.

Authors:  Eunice Teresinha Giampaolo; Janaina Habib Jorge; Ana Lúcia Machado; Ana Cláudia Pavarina; Carlos Eduardo Vergani
Journal:  Gerodontology       Date:  2010-01-14       Impact factor: 2.980

7.  Effect of water-bath post-polymerization on the mechanical properties, degree of conversion, and leaching of residual compounds of hard chairside reline resins.

Authors:  Vanessa M Urban; Ana L Machado; Carlos E Vergani; Eunice T Giampaolo; Ana C Pavarina; Fernando G de Almeida; Quezia B Cass
Journal:  Dent Mater       Date:  2009-01-10       Impact factor: 5.304

8.  Effect of phosphate group addition on the properties of denture base resins.

Authors:  Gaurav Puri; David W Berzins; Virendra B Dhuru; Periathamby A Raj; Sameer K Rambhia; Gunjan Dhir; Andrew R Dentino
Journal:  J Prosthet Dent       Date:  2008-10       Impact factor: 3.426

9.  Fracture toughness of cross-linked and non-cross-linked temporary crown and fixed partial denture materials.

Authors:  Markus Balkenhol; Heiko Köhler; Katharina Orbach; Bernd Wöstmann
Journal:  Dent Mater       Date:  2009-02-26       Impact factor: 5.304

10.  Acrylic removable appliances: comparative evaluation of different postpolymerization methods.

Authors:  Andreas Faltermeier; Martin Rosentritt; Dieter Müssig
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-03       Impact factor: 2.650

View more
  9 in total

1.  Comparison of shear bond strength of CAD/CAM and conventional heat-polymerized acrylic resin denture bases to auto-polymerized and heat-polymerized acrylic resins after aging.

Authors:  Masoumeh Taghva; Shabnam Enteghad; Ali Jamali; Mina Mohaghegh
Journal:  J Clin Exp Dent       Date:  2022-01-01

2.  Chemo-Mechanical Approach to Improve Repair Bond Strength of Denture Teeth.

Authors:  Zahra A AlZaher; Danah F Almaskin; Masoumah S Qaw; Tahani H Abu Showmi; Reem Abualsaud; Sultan Akhtar; Mohammed M Gad
Journal:  Int J Dent       Date:  2020-11-04

3.  Influence of artificial aging and ZrO2 nanoparticle-reinforced repair resin on the denture repair strength.

Authors:  Mohammed M Gad; Ahmed Rahoma; Reem Abualsaud; Ahmad M Al-Thobity; Sultan Akhtar; Intisar A Siddiqui; Fahad A Al-Harbi
Journal:  J Clin Exp Dent       Date:  2020-04-01

4.  Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study.

Authors:  G S Chandu; Pooja Asnani; Siddarth Gupta; Mohd Faisal Khan
Journal:  J Int Oral Health       Date:  2015-04

5.  Polymethylmethacrylate Incorporating Nanodiamonds for Denture Repair: In Vitro Study on the Mechanical Properties.

Authors:  Mohammed M Gad; Mohamed Saber Ali; Ahmad M Al-Thobity; Yousif A Al-Dulaijan; Mai El Zayat; Abdel-Naser M Emam; Sultan Akhtar; Soban Q Khan; Fahad A Al-Harbi; Shaimaa M Fouda
Journal:  Eur J Dent       Date:  2021-11-25

6.  3D-Printed Nanocomposite Denture-Base Resins: Effect of ZrO2 Nanoparticles on the Mechanical and Surface Properties In Vitro.

Authors:  Ali A Alshaikh; Abdulrahman Khattar; Ibrahim A Almindil; Majed H Alsaif; Sultan Akhtar; Soban Q Khan; Mohammed M Gad
Journal:  Nanomaterials (Basel)       Date:  2022-07-18       Impact factor: 5.719

7.  Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base.

Authors:  Se-Jick Park; Joon-Seok Lee
Journal:  J Adv Prosthodont       Date:  2022-08-29       Impact factor: 1.989

8.  In Vitro Assessment of Artificial Aging on the Antifungal Activity of PMMA Denture Base Material Modified with ZrO2 Nanoparticles.

Authors:  Shorouq Khalid Hamid; Lujain Ali Alghamdi; Faris A Alshahrani; Soban Q Khan; Asif Matin; Mohammed M Gad
Journal:  Int J Dent       Date:  2021-05-13

9.  The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material.

Authors:  Nick Polychronakis; Aspasia Sarafianou; Alcibiadis Zissis; Triantafillos Papadopoulos
Journal:  Acta Stomatol Croat       Date:  2017-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.