The self-aligning knee prosthesis: clinical and radiological outcome and survival analysis of a cruciate retaining meniscal bearing knee at 10-year follow-up.

R A van Stralen1, P G Anderson, A B Wymenga.   

Abstract

PURPOSE: Previously, the clinical and radiological results of the self-aligning cruciate retaining total knee prosthesis at 5-years follow-up were described. The 10-year follow-up is now reported to determine the clinical and radiological results and the survival of the prosthesis.
METHODS: A 10-year follow-up was performed in this prospectively followed cohort of 246 (232 patients) self-aligning, cruciate retaining total knee arthroplasties performed between 1995 and 1998. Because patients had died and others suffered from comorbidities making them unable to attend a follow-up consultation, data could be obtained for 105 prostheses. Clinical results were evaluated by the Knee Society Score, and radiological follow-up was performed on standard AP and lateral X-rays. All radiographs were evaluated for the presence of radiolucencies, osteolysis and wear.
RESULTS: At the 10-year follow-up, there were no new cases of revision so that the cumulative survival rate at 10 years remains 95%. The 10-year follow-up shows good clinical results with an average Knee Society Score of 154 (SD 35.7) and an average range of motion of 109° (SD 13.7). After excluding 25 prostheses for comorbidities, the mean 10-year KSS score increased from 154 to 163 (SD 26.2). On the other hand, for the ROM, the exclusion of the 25 prostheses had no influence on the mean ROM value of 109°. At the 10-year follow-up, none of the 100 available radiographs showed any radiolucencies >2 mm on any component.
CONCLUSIONS: Long-term follow-up of the mobile bearing, cruciate retaining, SAL-II total knee arthroplasty shows excellent clinical and radiological results without bearing dislocation. LEVEL OF EVIDENCE: Prospective cohort, Level IV.

Entities:  

Mesh:

Year:  2013        PMID: 23839209     DOI: 10.1007/s00167-013-2601-1

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  25 in total

1.  The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements.

Authors:  S Sathasivam; P S Walker; P A Campbell; K Rayner
Journal:  J Biomed Mater Res       Date:  2001-05-01

2.  Long-term survival analysis of posterior cruciate-retaining total knee arthroplasty.

Authors:  Lin Guo; Liu Yang; Jean Louis Briard; Xiao-jun Duan; Fu-you Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-10       Impact factor: 4.342

3.  An analysis of rotating-platform total knee replacements.

Authors:  Robert B Bourne; John Masonis; Mary Anthony
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

4.  Fat-pad impingement after total knee arthroplasty with the LCS A/P-Glide system.

Authors:  Inès A Kramers-de Quervain; Ivette Engel-Bicik; Wolfgang Miehlke; Tomas Drobny; Urs Munzinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-03-16       Impact factor: 4.342

5.  Cemented rotating-platform total knee replacement: a concise follow-up, at a minimum of twenty years, of a previous report.

Authors:  John J Callaghan; Christopher W Wells; Steve S Liu; Devon D Goetz; Richard C Johnston
Journal:  J Bone Joint Surg Am       Date:  2010-07-07       Impact factor: 5.284

6.  Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study.

Authors:  J Philippe Kretzer; Eike Jakubowitz; Jörn Reinders; Eva Lietz; Babak Moradi; Kerstin Hofmann; Robert Sonntag
Journal:  Acta Biomater       Date:  2010-09-29       Impact factor: 8.947

Review 7.  Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis.

Authors:  Toby O Smith; Farshid Ejtehadi; Rachel Nichols; Leigh Davies; Simon T Donell; Caroline B Hing
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-25       Impact factor: 4.342

8.  The EUROP total knee prosthesis: a ten-year follow-up study of a posterior cruciate-retaining design.

Authors:  A Mouttet; M-L Louis; V Sourdet
Journal:  Orthop Traumatol Surg Res       Date:  2011-07-01       Impact factor: 2.256

9.  Wear and lysis is the problem in modular TKA in the young OA patient at 10 years.

Authors:  Andrew N Odland; John J Callaghan; Steve S Liu; Christopher W Wells
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

10.  Rollback in posterior cruciate ligament-retaining total knee arthroplasty. A radiographic analysis.

Authors:  H Kim; R R Pelker; D H Gibson; J F Irving; J K Lynch
Journal:  J Arthroplasty       Date:  1997-08       Impact factor: 4.757

View more
  1 in total

1.  No clinical difference between fixed- and mobile-bearing cruciate-retaining total knee arthroplasty: a prospective randomized study.

Authors:  O Bailey; K Ferguson; E Crawfurd; P James; P A May; S Brown; M Blyth; W J Leach
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-09       Impact factor: 4.342

  1 in total