Literature DB >> 20883831

Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study.

J Philippe Kretzer1, Eike Jakubowitz, Jörn Reinders, Eva Lietz, Babak Moradi, Kerstin Hofmann, Robert Sonntag.   

Abstract

Unicondylar knee arthroplasty is an attractive alternative to total knee arthroplasty for selected patients with osteoarthritis. Mobile bearing knee designs have been developed to improve knee kinematics, lower contact stresses and reduced wear of ultra-high molecular weight polyethylene compared with fixed bearing designs. This study compared in vitro wear behavior of fixed and mobile unicondylar bearing designs. Analysis was performed using a force-controlled AMTI knee simulator according to ISO 14243-1:2002(E). The wear volume of the implants was determined gravimetrically. Optical surface characterization and an estimation of wear particle size and morphology were performed. Implant kinematic data for both designs were determined. The wear rates averaged 10.7 ± 0.59 mg per 10(6) cycles for the medial and 5.38 ± 0.63 mg per 10(6) cycles for the lateral components of the mobile bearings, compared with 7.51 ± 0.29 mg per 10(6) cycles and 3.04 ± 0.35 mg per 10(6) cycles for the fixed bearings. The mobile bearings therefore exhibited higher wear rates (P<0.01) compared with the fixed bearings. The tibial polyethylene inserts of the mobile bearings showed pronounced backside wear at the inferior surface. The kinematics of both designs was similar. However, anterior-posterior translation was lower in the mobile bearings. The wear particles were mainly elongated and small in size for both designs (P=0.462). This study shows that wear may play an important role in unicondylar mobile bearing knee designs. Advantages of unicondylar mobile designs compared with fixed bearing designs, which have been proposed in terms of wear behavior and improved kinematics, could not be confirmed.
Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20883831     DOI: 10.1016/j.actbio.2010.09.031

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  27 in total

1.  [Does increased tibial slope reduce the wear rate of unicompartmental knee prostheses? An in vitro investigation].

Authors:  P Weber; C Schröder; S Utzschneider; F Schmidutz; V Jansson; P E Müller
Journal:  Orthopade       Date:  2012-04       Impact factor: 1.087

2.  The self-aligning knee prosthesis: clinical and radiological outcome and survival analysis of a cruciate retaining meniscal bearing knee at 10-year follow-up.

Authors:  R A van Stralen; P G Anderson; A B Wymenga
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-10       Impact factor: 4.342

Review 3.  [Recommendations for unicondylar knee replacement in the course of time : A current inventory].

Authors:  J Beckmann; M T Hirschmann; G Matziolis; J Holz; R V Eisenhart-Rothe; C Becher
Journal:  Orthopade       Date:  2021-02       Impact factor: 1.087

4.  Anteroposterior and rotational stability in fixed and mobile bearing unicondylar knee arthroplasty: a cadaveric study using the robotic force sensor system.

Authors:  Roland Becker; Christian Mauer; Christian Stärke; Mathias Brosz; Thore Zantop; Christoph H Lohmann; Martin Schulze
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-07       Impact factor: 4.342

5.  [Principles of tribological analysis of endoprostheses].

Authors:  J P Kretzer; C Zietz; C Schröder; J Reinders; L Middelborg; A Paulus; R Sonntag; R Bader; S Utzschneider
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

Review 6.  [Revision after unicompartmental knee arthroplasty].

Authors:  G Mohr; J Martin; M Clarius
Journal:  Orthopade       Date:  2014-10       Impact factor: 1.087

7.  Toward the interpretation of the combined effect of size and body weight on the tribological performance of total knee prostheses.

Authors:  Santina Battaglia; Paola Taddei; Silvia Tozzi; Alessandra Sudanese; Saverio Affatato
Journal:  Int Orthop       Date:  2014-02-26       Impact factor: 3.075

8.  Medial unicondylar knee arthroplasty combined to anterior cruciate ligament reconstruction.

Authors:  Alberto Ventura; Claudio Legnani; Clara Terzaghi; Stefano Iori; Enrico Borgo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-10-14       Impact factor: 4.342

9.  Combined unicompartmental knee arthroplasty and anterior cruciate ligament reconstruction.

Authors:  Marco Tinius; Pierre Hepp; Roland Becker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-11       Impact factor: 4.342

Review 10.  Fixed- versus mobile-bearing unicondylar knee arthroplasty: are failure modes different?

Authors:  Tao Cheng; Daoyun Chen; Chen Zhu; Xiaoyun Pan; Xin Mao; Yongyuan Guo; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-09-25       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.