Literature DB >> 21511928

The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction.

M T Hirschmann1, P Konala, F Amsler, F Iranpour, N F Friederich, J P Cobb.   

Abstract

We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose. A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p < 0.001). 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice.

Mesh:

Year:  2011        PMID: 21511928     DOI: 10.1302/0301-620X.93B5.25893

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  75 in total

1.  No influence of femoral component rotation by the lateral femoral posterior condylar cartilage remnant technique on clinical outcomes in navigation-assisted TKA.

Authors:  Seong Hwan Kim; Yong-Beom Park; Dae Woong Ham; Jae-Sung Lee; Min-Ku Song; Han-Jun Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-02       Impact factor: 4.342

2.  Assessment of patient-specific instrumentation precision through bone resection measurements.

Authors:  F Zambianchi; A Colombelli; V Digennaro; A Marcovigi; R Mugnai; F Fiacchi; D Sandoni; A Belluati; F Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-24       Impact factor: 4.342

3.  Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review.

Authors:  Paweł Skowronek; Markus Arnold; Christian Starke; Agnieszka Bartyzel; Lukas B Moser; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-30       Impact factor: 4.342

4.  Presence of rotational errors in long leg radiographs after total knee arthroplasty and impact on measured lower limb and component alignment.

Authors:  Günther Maderbacher; Clemens Baier; Achim Benditz; Ferdinand Wagner; Felix Greimel; Joachim Grifka; Armin Keshmiri
Journal:  Int Orthop       Date:  2017-01-31       Impact factor: 3.075

Review 5.  SPECT/CT in patients with painful knee arthroplasty-what is the evidence?

Authors:  Michael T Hirschmann; Johann Henckel; Helmut Rasch
Journal:  Skeletal Radiol       Date:  2013-06-11       Impact factor: 2.199

6.  4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty.

Authors:  Helmut Rasch; Anna L Falkowski; Flavio Forrer; Johann Henckel; Michael T Hirschmann
Journal:  Skeletal Radiol       Date:  2013-05-22       Impact factor: 2.199

7.  Increased in vivo patellofemoral loading after total knee arthroplasty in resurfaced patellae.

Authors:  Omer Slevin; Florian A Schmid; Filippo Schiapparelli; Helmut Rasch; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-29       Impact factor: 4.342

8.  Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA.

Authors:  Michael T Hirschmann; Felix Amsler; Helmut Rasch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-06-06       Impact factor: 9.236

9.  Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.

Authors:  Kazumasa Yamamura; Yukihide Minoda; Ryo Sugama; Yoichi Ohta; Suguru Nakamura; Hideki Ueyama; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-25       Impact factor: 4.342

10.  Medial parapatellar approach leads to internal rotation of tibial component in total knee arthroplasty.

Authors:  Filippo-Franco Schiapparelli; Felix Amsler; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-05-30       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.