3D assessment of cortical bone porosity and tissue mineral density using high-resolution µCT: effects of resolution and threshold method.

Paolo E Palacio-Mancheno1, Adriana I Larriera, Stephen B Doty, Luis Cardoso, Susannah P Fritton.   

Abstract

Current micro-computed tomography (µCT) systems allow scanning bone at resolutions capable of three-dimensional (3D) characterization of intracortical vascular porosity and osteocyte lacunae. However, the scanning and reconstruction parameters along with the image segmentation method affect the accuracy of the measurements. In this study, the effects of scanning resolution and image threshold method in quantifying small features of cortical bone (vascular porosity, vascular canal diameter and separation, lacunar porosity and density, and tissue mineral density) were analyzed. Cortical bone from the tibia of Sprague-Dawley rats was scanned at 1-µm and 4-µm resolution, reconstructions were density-calibrated, and volumes of interest were segmented using approaches based on edge-detection or histogram analysis. In 1-µm resolution scans, the osteocyte lacunar spaces could be visualized, and it was possible to separate the lacunar porosity from the vascular porosity. At 4-µm resolution, the vascular porosity and vascular canal diameter were underestimated, and osteocyte lacunae were not effectively detected, whereas the vascular canal separation and tissue mineral density were overestimated compared to 1-µm resolution. Resolution had a much greater effect on the measurements than did threshold method, showing partial volume effects at resolutions coarser than 2 µm in two separate analyses, one of which assessed the effect of resolution on an object of known size with similar architecture to a vascular pore. Although there was little difference when using the edge-detection versus histogram-based threshold approaches, edge-detection was somewhat more effective in delineating canal architecture at finer resolutions (1-2 µm). In addition, use of a high-resolution (1 µm) density-based threshold on lower resolution (4 µm) density-calibrated images was not effective in improving the lower-resolution measurements. In conclusion, if measuring cortical vascular microarchitecture, especially in small animals, a µCT resolution of 1 to 2 µm is appropriate, whereas a resolution of at least 1 µm is necessary when assessing osteocyte lacunar porosity.
© 2014 American Society for Bone and Mineral Research.

Entities:  

Keywords:  INTRACORTICAL POROSITY; PARTIAL VOLUME EFFECT; RESOLUTION; VASCULAR POROSITY; µCT

Mesh:

Year:  2014        PMID: 23775635      PMCID: PMC3870034          DOI: 10.1002/jbmr.2012

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  28 in total

Review 1.  Guidelines for assessment of bone microstructure in rodents using micro-computed tomography.

Authors:  Mary L Bouxsein; Stephen K Boyd; Blaine A Christiansen; Robert E Guldberg; Karl J Jepsen; Ralph Müller
Journal:  J Bone Miner Res       Date:  2010-07       Impact factor: 6.741

2.  Effects of CT image segmentation methods on the accuracy of long bone 3D reconstructions.

Authors:  Kanchana Rathnayaka; Tony Sahama; Michael A Schuetz; Beat Schmutz
Journal:  Med Eng Phys       Date:  2010-10-27       Impact factor: 2.242

3.  Influence of vascular porosity on fluid flow and nutrient transport in loaded cortical bone.

Authors:  Grant C Goulet; Nicolas Hamilton; David Cooper; Dennis Coombe; David Tran; Robert Martinuzzi; Ronald F Zernicke
Journal:  J Biomech       Date:  2008-06-04       Impact factor: 2.712

Review 4.  Hierarchical microimaging of bone structure and function.

Authors:  Ralph Müller
Journal:  Nat Rev Rheumatol       Date:  2009-07       Impact factor: 20.543

5.  3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia.

Authors:  H M Britz; J Jokihaara; O V Leppänen; T Järvinen; D M L Cooper
Journal:  J Microsc       Date:  2010-10       Impact factor: 1.758

6.  High resolution micro arthrography of hard and soft tissues in a murine model.

Authors:  X I Gu; P E Palacio-Mancheno; D J Leong; Y A Borisov; E Williams; N Maldonado; D Laudier; R J Majeska; M B Schaffler; H B Sun; L Cardoso
Journal:  Osteoarthritis Cartilage       Date:  2012-05-18       Impact factor: 6.576

7.  Changes in intracortical microporosities induced by pharmaceutical treatment of osteoporosis as detected by high resolution micro-CT.

Authors:  Steven M Tommasini; Andrea Trinward; Alvin S Acerbo; Francesco De Carlo; Lisa M Miller; Stefan Judex
Journal:  Bone       Date:  2011-12-28       Impact factor: 4.398

8.  Simultaneous 3D visualization and quantification of murine bone and bone vasculature using micro-computed tomography and vascular replica.

Authors:  Philipp Schneider; Thomas Krucker; Eric Meyer; Alexandra Ulmann-Schuler; Bruno Weber; Marco Stampanoni; Ralph Müller
Journal:  Microsc Res Tech       Date:  2009-09       Impact factor: 2.769

9.  Ultrastructural properties in cortical bone vary greatly in two inbred strains of mice as assessed by synchrotron light based micro- and nano-CT.

Authors:  Philipp Schneider; Martin Stauber; Romain Voide; Marco Stampanoni; Leah Rae Donahue; Ralph Müller
Journal:  J Bone Miner Res       Date:  2007-10       Impact factor: 6.741

10.  Effect of voxel size on 3D micro-CT analysis of cortical bone porosity.

Authors:  David Cooper; Andrei Turinsky; Christoph Sensen; Benedikt Hallgrimsson
Journal:  Calcif Tissue Int       Date:  2007-03-05       Impact factor: 4.333

View more
  34 in total

1.  Imaging and analysis of microcalcifications and lipid/necrotic core calcification in fibrous cap atheroma.

Authors:  Natalia Maldonado; Adreanne Kelly-Arnold; Damien Laudier; Sheldon Weinbaum; Luis Cardoso
Journal:  Int J Cardiovasc Imaging       Date:  2015-04-03       Impact factor: 2.357

2.  Microstructure, mineral and mechanical properties of teleost intermuscular bones.

Authors:  I A K Fiedler; S Zeveleva; A Duarte; X Zhao; B Depalle; L Cardoso; S Jin; J P Berteau
Journal:  J Biomech       Date:  2019-07-17       Impact factor: 2.712

3.  The use of nano-computed tomography to enhance musculoskeletal research.

Authors:  Basma M Khoury; Erin M R Bigelow; Lauren M Smith; Stephen H Schlecht; Erica L Scheller; Nelly Andarawis-Puri; Karl J Jepsen
Journal:  Connect Tissue Res       Date:  2015-02-03       Impact factor: 3.417

Review 4.  Assessment of bone vascularization and its role in bone remodeling.

Authors:  Marie-Hélène Lafage-Proust; Bernard Roche; Max Langer; Damien Cleret; Arnaud Vanden Bossche; Thomas Olivier; Laurence Vico
Journal:  Bonekey Rep       Date:  2015-04-08

5.  Semi-automatic micro-CT segmentation of the midfoot using calibrated thresholds.

Authors:  Melissa R Requist; Yantarat Sripanich; Andrew C Peterson; Tim Rolvien; Alexej Barg; Amy L Lenz
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-02-19       Impact factor: 2.924

6.  Effect of tissue properties, shape and orientation of microcalcifications on vulnerable cap stability using different hyperelastic constitutive models.

Authors:  Luis Cardoso; Adreanne Kelly-Arnold; Natalia Maldonado; Damien Laudier; Sheldon Weinbaum
Journal:  J Biomech       Date:  2014-01-13       Impact factor: 2.712

7.  Human cochlear hydrodynamics: A high-resolution μCT-based finite element study.

Authors:  Annalisa De Paolis; Hirobumi Watanabe; Jeremy T Nelson; Marom Bikson; Mark Packer; Luis Cardoso
Journal:  J Biomech       Date:  2016-11-10       Impact factor: 2.712

8.  Acoustic diffusion constant of cortical bone: Numerical simulation study of the effect of pore size and pore density on multiple scattering.

Authors:  Yasamin Karbalaeisadegh; Omid Yousefian; Gianluca Iori; Kay Raum; Marie Muller
Journal:  J Acoust Soc Am       Date:  2019-08       Impact factor: 1.840

9.  Validation of cortical bone mineral density distribution using micro-computed tomography.

Authors:  Maleeha Mashiatulla; Ryan D Ross; D Rick Sumner
Journal:  Bone       Date:  2017-03-29       Impact factor: 4.398

10.  Microstructural changes associated with osteoporosis negatively affect loading-induced fluid flow around osteocytes in cortical bone.

Authors:  Vittorio Gatti; Evan M Azoulay; Susannah P Fritton
Journal:  J Biomech       Date:  2017-11-16       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.