Literature DB >> 17340226

Effect of voxel size on 3D micro-CT analysis of cortical bone porosity.

David Cooper1, Andrei Turinsky, Christoph Sensen, Benedikt Hallgrimsson.   

Abstract

This study examines the impact of voxel size on 3D micro-CT analysis of human cortical bone porosity. The study is based on computed microtomography scans of 10 human anterior femoral midshaft specimens acquired at 5, 10, and 15 microm voxel sizes. Artificial voxel sizes (10, 20, and 40 microm) were generated from the smallest scan voxel size (5 microm) in order to compare actual scanning with artificial degradation, a method employed in other similar studies. Canal volume fraction (CaV/TV), canal surface to volume ratio (CaS/CaV), mean canal diameter (CaDm), mean canal separation (CaSp), canal number (CaN), degree of anisotropy (DA), and canal connectivity density (CaConnD) were calculated from matching volumes of interest for all datasets. Qualitatively, the clarity of the actual scan datasets deteriorated rapidly as voxel size increased. In contrast, within the artificially generated datasets, the clarity of cortical pores was better maintained until the largest voxel size (40 microm). Mean absolute percent error values, correlation coefficients, and paired t-tests revealed a pattern of increasing, and generally significant, differences between the smallest and progressively larger voxel sizes (both scanned and artificial). Relative to the actual scans, however, the artificial datasets were less sensitive to changing voxel size. These findings indicated that subtle changes in voxel size, within the range examined, have a considerable effect on human cortical porosity structural parameters. Additionally, the use of artificially increased voxel sizes should be viewed with caution as they may not reflect what can actually be obtained by scanning.

Entities:  

Mesh:

Year:  2007        PMID: 17340226     DOI: 10.1007/s00223-005-0274-6

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  25 in total

1.  The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure.

Authors:  Willy Tjong; Galateia J Kazakia; Andrew J Burghardt; Sharmila Majumdar
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Structural analysis of cortical porosity applied to HR-pQCT data.

Authors:  Willy Tjong; Jasmine Nirody; Andrew J Burghardt; Julio Carballido-Gamio; Galateia J Kazakia
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

3.  Three-dimensional observation of mouse tongue muscles using micro-computed tomography.

Authors:  Hidekazu Aoyagi; Shin-Ichi Iwasaki; Kenzirou Nakamura
Journal:  Odontology       Date:  2013-08-22       Impact factor: 2.634

4.  Visualization of 3D osteon morphology by synchrotron radiation micro-CT.

Authors:  D M L Cooper; B Erickson; A G Peele; K Hannah; C D L Thomas; J G Clement
Journal:  J Anat       Date:  2011-06-06       Impact factor: 2.610

5.  Three-dimensional observation of the mouse embryo by micro-computed tomography: composition of the trigeminal ganglion.

Authors:  Hidekazu Aoyagi; Kohzo Tsuchikawa; Shin-ichi Iwasaki
Journal:  Odontology       Date:  2010-02-16       Impact factor: 2.634

6.  3D characterization of pores in the cortical bone of human femur in the elderly at different locations as determined by synchrotron micro-computed tomography images.

Authors:  C Chappard; S Bensalah; C Olivier; P J Gouttenoire; A Marchadier; C Benhamou; F Peyrin
Journal:  Osteoporos Int       Date:  2012-07-20       Impact factor: 4.507

7.  The use of light/chemically hardened polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide graft material in combination with polyanhydride around implants and extraction sockets in minipigs: Part II: histologic and micro-CT evaluations.

Authors:  Hatice Hasturk; Alpdogan Kantarci; Mazen Ghattas; Smit J Dangaria; Rima Abdallah; Elise F Morgan; Thomas G H Diekwisch; Arthur Ashman; Thomas Van Dyke
Journal:  J Periodontol       Date:  2014-02-06       Impact factor: 6.993

8.  Micro-computed tomography characterization of tissue engineering scaffolds: effects of pixel size and rotation step.

Authors:  Ibrahim Fatih Cengiz; Joaquim Miguel Oliveira; Rui L Reis
Journal:  J Mater Sci Mater Med       Date:  2017-07-18       Impact factor: 3.896

9.  Assessing forearm fracture risk in postmenopausal women.

Authors:  L J Melton; D Christen; B L Riggs; S J Achenbach; R Müller; G H van Lenthe; S Amin; E J Atkinson; S Khosla
Journal:  Osteoporos Int       Date:  2009-08-28       Impact factor: 4.507

10.  3D assessment of cortical bone porosity and tissue mineral density using high-resolution µCT: effects of resolution and threshold method.

Authors:  Paolo E Palacio-Mancheno; Adriana I Larriera; Stephen B Doty; Luis Cardoso; Susannah P Fritton
Journal:  J Bone Miner Res       Date:  2014-01       Impact factor: 6.741

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.