Literature DB >> 33606178

Semi-automatic micro-CT segmentation of the midfoot using calibrated thresholds.

Melissa R Requist1,2, Yantarat Sripanich1,3, Andrew C Peterson1, Tim Rolvien4, Alexej Barg5,6, Amy L Lenz7.   

Abstract

PURPOSE: In the field of skeletal research, accurate and reliable segmentation methods are necessary for quantitative micro-CT analysis to assess bone quality. We propose a method of semi-automatic image segmentation of the midfoot, using the cuneiform bones as a model, based on thresholds set by phantom calibration that allows reproducible results in low cortical thickness bones.
METHODS: Manual and semi-automatic segmentation methods were compared in micro-CT scans of the medial and intermediate cuneiforms of 24 cadaveric specimens. The manual method used intensity thresholds, hole filling, and manual cleanup. The semi-automatic method utilized calibrated bone and soft tissue thresholds Boolean subtraction to cleanly identify edges before hole filling. Intra- and inter-rater reliability was tested for the semi-automatic method in all specimens. Mask volume and average bone mineral density (BMD) were measured for all masks, and the three-dimensional models were compared to the initial semi-automatic segmentation using an unsigned distance part comparison analysis. Segmentation methods were compared with paired t-tests with significance level 0.05, and reliability was analyzed by calculating intra-class correlation coefficients.
RESULTS: There were statistically significant differences in mask volume and BMD between the manual and semi-automatic segmentation methods in both bones. The intra- and inter-reliability was excellent for mask volume and bone density in both bones. Part comparisons showed a higher maximum distance between surfaces for the manual segmentation than the repeat semi-automatic segmentations.
CONCLUSION: We developed a semi-automatic micro-CT segmentation method based on calibrated thresholds. This method was designed specifically for use in bones with high rates of curvature and low cortical bone density, such as the cuneiforms, where traditional threshold-based segmentation is more challenging. Our method shows improvement over manual segmentation and was highly reliable, making it appropriate for use in quantitative micro-CT analysis.

Keywords:  Calibrated phantom; Cuneiforms; Micro-CT; Semi-automatic segmentation

Mesh:

Year:  2021        PMID: 33606178     DOI: 10.1007/s11548-021-02318-z

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  25 in total

1.  Interphantom and interscanner variations for Hounsfield units--establishment of reference values for HU in a commercial QA phantom.

Authors:  Erlend Peter Skaug Sande; Anne Catrine Traegde Martinsen; Eli Olaug Hole; Hilde M Olerud
Journal:  Phys Med Biol       Date:  2010-08-16       Impact factor: 3.609

Review 2.  Application of quantitative computed tomography for assessment of trabecular bone mineral density, microarchitecture and mechanical property.

Authors:  Song Shou Mao; Dong Li; Yanting Luo; Younus Saleem Syed; Matthew J Budoff
Journal:  Clin Imaging       Date:  2015-09-21       Impact factor: 1.605

3.  The Effect of Quantitative Computed Tomography Acquisition Protocols on Bone Mineral Density Estimation.

Authors:  Hugo Giambini; Dan Dragomir-Daescu; Paul M Huddleston; Jon J Camp; Kai-Nan An; Ahmad Nassr
Journal:  J Biomech Eng       Date:  2015-11       Impact factor: 2.097

4.  Clinical Use of Quantitative Computed Tomography (QCT) of the Hip in the Management of Osteoporosis in Adults: the 2015 ISCD Official Positions-Part I.

Authors:  Klaus Engelke; Thomas Lang; Sundeep Khosla; Ling Qin; Philippe Zysset; William D Leslie; John A Shepherd; John T Schousboe
Journal:  J Clin Densitom       Date:  2015 Jul-Sep       Impact factor: 2.617

5.  3D surface voxel tracing corrector for accurate bone segmentation.

Authors:  Haoyan Guo; Sicong Song; Jinke Wang; Maozu Guo; Yuanzhi Cheng; Yadong Wang; Shinichi Tamura
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06-18       Impact factor: 2.924

Review 6.  Practical considerations for obtaining high quality quantitative computed tomography data of the skeletal system.

Authors:  Karen L Troy; W Brent Edwards
Journal:  Bone       Date:  2018-01-12       Impact factor: 4.398

7.  Automatic segmentation of the uterus on MRI using a convolutional neural network.

Authors:  Yasuhisa Kurata; Mizuho Nishio; Aki Kido; Koji Fujimoto; Masahiro Yakami; Hiroyoshi Isoda; Kaori Togashi
Journal:  Comput Biol Med       Date:  2019-09-05       Impact factor: 4.589

8.  The European Spine Phantom--a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT.

Authors:  W A Kalender; D Felsenberg; H K Genant; M Fischer; J Dequeker; J Reeve
Journal:  Eur J Radiol       Date:  1995-07       Impact factor: 3.528

9.  Fully automatic segmentation of the femur from 3D-CT images using primitive shape recognition and statistical shape models.

Authors:  Lassad Ben Younes; Yoshikazu Nakajima; Toki Saito
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-10-08       Impact factor: 2.924

10.  Manual segmentation versus semi-automated segmentation for quantifying vestibular schwannoma volume on MRI.

Authors:  Hari McGrath; Peichao Li; Reuben Dorent; Robert Bradford; Shakeel Saeed; Sotirios Bisdas; Sebastien Ourselin; Jonathan Shapey; Tom Vercauteren
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-07-16       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.