Effects of CT image segmentation methods on the accuracy of long bone 3D reconstructions.

Kanchana Rathnayaka1, Tony Sahama, Michael A Schuetz, Beat Schmutz.   

Abstract

An accurate and accessible image segmentation method is in high demand for generating 3D bone models from CT scan data, as such models are required in many areas of medical research. Even though numerous sophisticated segmentation methods have been published over the years, most of them are not readily available to the general research community. Therefore, this study aimed to quantify the accuracy of three popular image segmentation methods, two implementations of intensity thresholding and Canny edge detection, for generating 3D models of long bones. In order to reduce user dependent errors associated with visually selecting a threshold value, we present a new approach of selecting an appropriate threshold value based on the Canny filter. A mechanical contact scanner in conjunction with a microCT scanner was utilised to generate the reference models for validating the 3D bone models generated from CT data of five intact ovine hind limbs. When the overall accuracy of the bone model is considered, the three investigated segmentation methods generated comparable results with mean errors in the range of 0.18-0.24 mm. However, for the bone diaphysis, Canny edge detection and Canny filter based thresholding generated 3D models with a significantly higher accuracy compared to those generated through visually selected thresholds. This study demonstrates that 3D models with sub-voxel accuracy can be generated utilising relatively simple segmentation methods that are available to the general research community.
Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

Mesh:

Year:  2010        PMID: 21030288     DOI: 10.1016/j.medengphy.2010.10.002

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  25 in total

1.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

2.  How do CAD models compare with reverse engineered manufactured components for use in wear analysis?

Authors:  Matthew G Teeter; Douglas D R Naudie; Robert B Bourne; David W Holdsworth
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

Review 3.  Finite Element-Based Mechanical Assessment of Bone Quality on the Basis of In Vivo Images.

Authors:  Dieter H Pahr; Philippe K Zysset
Journal:  Curr Osteoporos Rep       Date:  2016-12       Impact factor: 5.096

4.  Semi-automatic micro-CT segmentation of the midfoot using calibrated thresholds.

Authors:  Melissa R Requist; Yantarat Sripanich; Andrew C Peterson; Tim Rolvien; Alexej Barg; Amy L Lenz
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-02-19       Impact factor: 2.924

5.  Can MRI accurately detect pilon articular malreduction? A quantitative comparison between CT and 3T MRI bone models.

Authors:  Shairah Radzi; Constantin Edmond Dlaska; Gary Cowin; Mark Robinson; Jit Pratap; Michael Andreas Schuetz; Sanjay Mishra; Beat Schmutz
Journal:  Quant Imaging Med Surg       Date:  2016-12

6.  Reliability and correlation analysis of computed methods to convert conventional 2D radiological hindfoot measurements to a 3D setting using weightbearing CT.

Authors:  A Burssens; J Peeters; M Peiffer; R Marien; T Lenaerts; G Vandeputte; J Victor
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-09       Impact factor: 2.924

7.  Graft tension of the posterior cruciate ligament using a finite element model.

Authors:  Young-Jin Seo; Si Young Song; In Sung Kim; Myeong Jae Seo; Yoon Sang Kim; Yon-Sik Yoo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-14       Impact factor: 4.342

8.  Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Zachary W Sisko; Matthew G Teeter; Brent A Lanting; James L Howard; Richard W McCalden; Douglas D Naudie; Steven J MacDonald; Edward M Vasarhelyi
Journal:  Clin Orthop Relat Res       Date:  2017-09-13       Impact factor: 4.176

9.  3D assessment of cortical bone porosity and tissue mineral density using high-resolution µCT: effects of resolution and threshold method.

Authors:  Paolo E Palacio-Mancheno; Adriana I Larriera; Stephen B Doty; Luis Cardoso; Susannah P Fritton
Journal:  J Bone Miner Res       Date:  2014-01       Impact factor: 6.741

10.  Metal artifacts from titanium and steel screws in CT, 1.5T and 3T MR images of the tibial Pilon: a quantitative assessment in 3D.

Authors:  Shairah Radzi; Gary Cowin; Mark Robinson; Jit Pratap; Andrew Volp; Michael A Schuetz; Beat Schmutz
Journal:  Quant Imaging Med Surg       Date:  2014-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.