Literature DB >> 23731380

Enabling quantitative analysis in ambient ionization mass spectrometry: internal standard coated capillary samplers.

Jiangjiang Liu1, R Graham Cooks, Zheng Ouyang.   

Abstract

We describe a sampling method using glass capillaries for quantitative analysis of trace analytes in small volumes of complex mixtures (~1 μL) using ambient ionization mass spectrometry. The internal surface of a sampling glass capillary was coated with internal standard then used to draw liquid sample and so transfer both the analyte and internal standard in a single fixed volume onto a substrate for analysis. The internal standard was automatically mixed into the sample during this process and the volumes of the internal standard solution and sample are both fixed by the capillary volume. Precision in quantitation is insensitive to variations in length of the capillary, making the preparation of the sampling capillary simple and providing a robust sampling protocol. Significant improvements in quantitation accuracy were obtained for analysis of 1 μL samples using various ambient ionization methods.

Entities:  

Mesh:

Year:  2013        PMID: 23731380      PMCID: PMC3705643          DOI: 10.1021/ac401056q

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  18 in total

1.  Silica coated paper substrate for paper-spray analysis of therapeutic drugs in dried blood spots.

Authors:  Zhiping Zhang; Wei Xu; Nicholas E Manicke; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2011-12-23       Impact factor: 6.986

2.  Quantitative analysis of therapeutic drugs in dried blood spot samples by paper spray mass spectrometry: an avenue to therapeutic drug monitoring.

Authors:  Nicholas Edward Manicke; Paul Abu-Rabie; Neil Spooner; Zheng Ouyang; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2011-06-21       Impact factor: 3.109

3.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

Review 4.  Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS.

Authors:  Raymond Naxing Xu; Leimin Fan; Matthew J Rieser; Tawakol A El-Shourbagy
Journal:  J Pharm Biomed Anal       Date:  2007-02-13       Impact factor: 3.935

Review 5.  Detection Technologies. Ambient mass spectrometry.

Authors:  R Graham Cooks; Zheng Ouyang; Zoltan Takats; Justin M Wiseman
Journal:  Science       Date:  2006-03-17       Impact factor: 47.728

6.  Paper spray for direct analysis of complex mixtures using mass spectrometry.

Authors:  He Wang; Jiangjiang Liu; R Graham Cooks; Zheng Ouyang
Journal:  Angew Chem Int Ed Engl       Date:  2010       Impact factor: 15.336

7.  Ambient sampling/ionization mass spectrometry: applications and current trends.

Authors:  Glenn A Harris; Asiri S Galhena; Facundo M Fernández
Journal:  Anal Chem       Date:  2011-05-06       Impact factor: 6.986

8.  Real-time, in vivo monitoring and pharmacokinetics of valproic acid via a novel biomarker in exhaled breath.

Authors:  Gerardo Gamez; Liang Zhu; Andreas Disko; Huanwen Chen; Vladimir Azov; Konstantin Chingin; Günter Krämer; Renato Zenobi
Journal:  Chem Commun (Camb)       Date:  2011-03-04       Impact factor: 6.222

9.  Mass spectrometry sampling under ambient conditions with desorption electrospray ionization.

Authors:  Zoltán Takáts; Justin M Wiseman; Bogdan Gologan; R Graham Cooks
Journal:  Science       Date:  2004-10-15       Impact factor: 47.728

10.  Low-temperature plasma probe for ambient desorption ionization.

Authors:  Jason D Harper; Nicholas A Charipar; Christopher C Mulligan; Xinrong Zhang; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2008-12-01       Impact factor: 6.986

View more
  11 in total

1.  A Polymer Coating Transfer Enrichment Method for Direct Mass Spectrometry Analysis of Lipids in Biofluid Samples.

Authors:  Wenpeng Zhang; Spencer Chiang; Zishuai Li; Qinhua Chen; Yu Xia; Zheng Ouyang
Journal:  Angew Chem Int Ed Engl       Date:  2019-03-27       Impact factor: 15.336

2.  Ambient ionization and miniature mass spectrometry system for chemical and biological analysis.

Authors:  Xiaoxiao Ma; Zheng Ouyang
Journal:  Trends Analyt Chem       Date:  2016-12       Impact factor: 12.296

3.  Using miniature MS system with automatic blood sampler for preclinical pharmacokinetics study.

Authors:  Fan Pu; Wenpeng Zhang; Kevin P Bateman; Yong Liu; Roy Helmy; Zheng Ouyang
Journal:  Bioanalysis       Date:  2017-11-02       Impact factor: 2.681

4.  Development of miniature mass spectrometry systems for bioanalysis outside the conventional laboratories.

Authors:  Xiaoyu Zhou; Jiangjiang Liu; Robert Graham Cooks; Zheng Ouyang
Journal:  Bioanalysis       Date:  2014-06       Impact factor: 2.681

5.  Direct Mass Spectrometry Analysis of Untreated Samples of Ultralow Amounts Using Extraction Nano-Electrospray.

Authors:  Yue Ren; Jiangjiang Liu; Linfan Li; Morgan N McLuckey; Zheng Ouyang
Journal:  Anal Methods       Date:  2013-12-07       Impact factor: 2.896

Review 6.  Direct sampling mass spectrometry for clinical analysis.

Authors:  Fan Pu; Spencer Chiang; Wenpeng Zhang; Zheng Ouyang
Journal:  Analyst       Date:  2019-02-11       Impact factor: 4.616

7.  Direct mass spectrometry analysis of biofluid samples using slug-flow microextraction nano-electrospray ionization.

Authors:  Yue Ren; Morgan N McLuckey; Jiangjiang Liu; Zheng Ouyang
Journal:  Angew Chem Int Ed Engl       Date:  2014-10-05       Impact factor: 15.336

Review 8.  Paper spray ionization mass spectrometry: recent advances and clinical applications.

Authors:  Spencer Chiang; Wenpeng Zhang; Zheng Ouyang
Journal:  Expert Rev Proteomics       Date:  2018-09-26       Impact factor: 3.940

9.  Quantitative analysis of biofluid spots by coated blade spray mass spectrometry, a new approach to rapid screening.

Authors:  Germán Augusto Gómez-Ríos; Marcos Tascon; Nathaly Reyes-Garcés; Ezel Boyacı; Justen Poole; Janusz Pawliszyn
Journal:  Sci Rep       Date:  2017-11-23       Impact factor: 4.379

10.  Mini 12, miniature mass spectrometer for clinical and other applications--introduction and characterization.

Authors:  Linfan Li; Tsung-Chi Chen; Yue Ren; Paul I Hendricks; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2014-02-24       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.