Literature DB >> 19551980

Low-temperature plasma probe for ambient desorption ionization.

Jason D Harper1, Nicholas A Charipar, Christopher C Mulligan, Xinrong Zhang, R Graham Cooks, Zheng Ouyang.   

Abstract

A low-temperature plasma (LTP) probe has been developed for ambient desorption ionization. An ac electric field is used to induce a dielectric barrier discharge through use of a specially designed electrode configuration. The low-temperature plasma is extracted from the probe where it interacts directly with the sample being analyzed, desorbing and ionizing surface molecules in the ambient environment. This allows experiments to be performed without damage to the sample or underlying substrate and, in the case of biological analysis on skin surfaces, without electrical shock or perceptible heating. Positive or negative ions are produced from a wide range of chemical compounds in the pure stateand as mixtures in the gaseous, solution, or condensed phases, using He, Ar, N2, or ambient air as the discharge gas. Limited fragmentation occurs, although it is greater in the cases of the molecular than the atomic discharge gases. The effectiveness of the LTP probe has been demonstrated by recording characteristic mass spectra and tandem mass spectra of samples containing hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and 2,4,6-trinitrotoluene (TNT) from poly(tetrafluoroethylene) (PTFE) surfaces where limits of detection are as low as 5 pg. Other performance characteristics, when using a commercial ion trap mass spectrometer, include 3-4 orders of magnitude linear dynamic range in favorable cases. Demonstration applications include direct analysis of cocaine from human skin, determination of active ingredients directly in drug tablets, and analysis of toxic and therapeutic compounds in complex biological samples. Ionization of chemicals directly from bulk aqueous solution has been demonstrated, where limits of detection are as low as 1 ppb. Large surface area sampling and control of fragmentation by a simple adjustment of the electrode configuration during operation are other demonstrated characteristics of the method.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19551980     DOI: 10.1021/ac801641a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  83 in total

1.  Miniaturization of Mass Spectrometry Analysis Systems.

Authors:  Wei Xu; Nicholas E Manicke; Graham R Cooks; Zheng Ouyang
Journal:  JALA Charlottesv Va       Date:  2010-12

2.  Direct detection of pharmaceuticals and personal care products from aqueous samples with thermally-assisted desorption electrospray ionization mass spectrometry.

Authors:  Ian S Campbell; Alain T Ton; Christopher C Mulligan
Journal:  J Am Soc Mass Spectrom       Date:  2011-05-05       Impact factor: 3.109

3.  Ultrasonication-assisted spray ionization mass spectrometry for the analysis of biomolecules in solution.

Authors:  Tsung-Yi Chen; Jia-Yi Lin; Jen-Yi Chen; Yu-Chie Chen
Journal:  J Am Soc Mass Spectrom       Date:  2010-05-06       Impact factor: 3.109

Review 4.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

5.  Ambient Molecular Analysis of Biological Tissue Using Low-Energy, Femtosecond Laser Vaporization and Nanospray Postionization Mass Spectrometry.

Authors:  Fengjian Shi; Paul M Flanigan; Jieutonne J Archer; Robert J Levis
Journal:  J Am Soc Mass Spectrom       Date:  2015-12-14       Impact factor: 3.109

6.  Multimodal Vacuum-Assisted Plasma Ion (VaPI) Source with Transmission Mode and Laser Ablation Sampling Capabilities.

Authors:  Joel D Keelor; Paul B Farnsworth; Arthur L Weber; Heather Abbott-Lyon; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2016-02-16       Impact factor: 3.109

7.  Neutral desorption using a sealed enclosure to sample explosives on human skin for rapid detection by EESI-MS.

Authors:  Huanwen Chen; Bin Hu; Yan Hu; Yanfu Huan; Zhiquan Zhou; Xiaolin Qiao
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-27       Impact factor: 3.109

8.  Mass spectral molecular networking of living microbial colonies.

Authors:  Jeramie Watrous; Patrick Roach; Theodore Alexandrov; Brandi S Heath; Jane Y Yang; Roland D Kersten; Menno van der Voort; Kit Pogliano; Harald Gross; Jos M Raaijmakers; Bradley S Moore; Julia Laskin; Nuno Bandeira; Pieter C Dorrestein
Journal:  Proc Natl Acad Sci U S A       Date:  2012-05-14       Impact factor: 11.205

9.  Humidity Effects on Fragmentation in Plasma-Based Ambient Ionization Sources.

Authors:  G Asher Newsome; Luke K Ackerman; Kevin J Johnson
Journal:  J Am Soc Mass Spectrom       Date:  2015-09-18       Impact factor: 3.109

10.  Use of Interrupted Helium Flow in the Analysis of Vapor Samples with Flowing Atmospheric-Pressure Afterglow-Mass Spectrometry.

Authors:  Andrew P Storey; Offer M Zeiri; Steven J Ray; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2016-10-18       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.