Literature DB >> 17360141

Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS.

Raymond Naxing Xu1, Leimin Fan, Matthew J Rieser, Tawakol A El-Shourbagy.   

Abstract

Liquid chromatography linked to tandem mass spectrometry (LC-MS/MS) has played an important role in pharmacokinetics and metabolism studies at various drug development stages since its introduction to the pharmaceutical industry. This article reviews the most recent advances in sample preparation, separation, and the mass spectrometric aspects of high-throughput quantitative bioanalysis of drug and metabolites in biological matrices. Newly introduced techniques such as ultra-performance liquid chromatography with small particles (sub-2 microm) and monolithic chromatography offer improvements in speed, resolution and sensitivity compared to conventional chromatographic techniques. Hydrophilic interaction chromatography (HILIC) on silica columns with low aqueous/high organic mobile phase is emerging as a valuable supplement to the reversed-phase LC-MS/MS. Sample preparation formatted to 96-well plates has allowed for semi-automation of off-line sample preparation techniques, significantly impacting throughput. On-line solid-phase extraction (SPE) utilizing column-switching techniques is rapidly gaining acceptance in bioanalytical applications to reduce both time and labor required to produce bioanalytical results. Extraction sorbents for on-line SPE extend to an array of media including large particles for turbulent flow chromatography, restricted access materials (RAM), monolithic materials, and disposable cartridges utilizing traditional packings such as those used in Spark Holland systems. In the end, this paper also discusses recent studies of matrix effect in LC-MS/MS analysis and how to reduce/eliminate matrix effect in method development and validation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17360141     DOI: 10.1016/j.jpba.2007.02.006

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  44 in total

1.  Relative quantification of serum proteins from pancreatic ductal adenocarcinoma patients by stable isotope dilution liquid chromatography-mass spectrometry.

Authors:  Angela Y Wehr; Wei-Ting Hwang; Ian A Blair; Kenneth H Yu
Journal:  J Proteome Res       Date:  2012-02-15       Impact factor: 4.466

2.  Using dried blood spot sampling to improve data quality and reduce animal use in mouse pharmacokinetic studies.

Authors:  Enaksha R Wickremsinhe; Everett J Perkins
Journal:  J Am Assoc Lab Anim Sci       Date:  2015-03       Impact factor: 1.232

3.  Automated solid-phase microextraction and thin-film microextraction for high-throughput analysis of biological fluids and ligand-receptor binding studies.

Authors:  Dajana Vuckovic; Erasmus Cudjoe; Florin Marcel Musteata; Janusz Pawliszyn
Journal:  Nat Protoc       Date:  2010-01-07       Impact factor: 13.491

4.  LC-MS/MS in the Clinical Laboratory - Where to From Here?

Authors:  Stefan Kg Grebe; Ravinder J Singh
Journal:  Clin Biochem Rev       Date:  2011-02

5.  Evaluation of the concentrations and distribution of carbonyl compounds in selected areas of a Brazilian bus terminal.

Authors:  Soraya de Mendonça Ochs; Leonardo de Almeida Furtado; Annibal Duarte Pereira Netto
Journal:  Environ Sci Pollut Res Int       Date:  2015-01-22       Impact factor: 4.223

6.  Utilizing Internal Standard Responses to Assess Risk on Reporting Bioanalytical Results from Hemolyzed Samples.

Authors:  Eliza N Fung; Anne-Françoise Aubry; Alban Allentoff; Qin C Ji
Journal:  AAPS J       Date:  2015-05-15       Impact factor: 4.009

7.  Development and validation of a UPLC method for rapid and simultaneous analysis of proton pump inhibitors.

Authors:  Richard T Addo; Kenneth Davis; Ruhi Ubale; Joel S Owen; E Blake Watkins
Journal:  AAPS PharmSciTech       Date:  2014-08-27       Impact factor: 3.246

8.  Quantitative mass spectrometry imaging of emtricitabine in cervical tissue model using infrared matrix-assisted laser desorption electrospray ionization.

Authors:  Mark T Bokhart; Elias Rosen; Corbin Thompson; Craig Sykes; Angela D M Kashuba; David C Muddiman
Journal:  Anal Bioanal Chem       Date:  2014-10-16       Impact factor: 4.142

9.  Simultaneous determination of cyclophosphamide and carboxyethylphosphoramide mustard in human plasma using online extraction and electrospray tandem mass spectrometry (HTLC-ESI-MS/MS).

Authors:  Feng Bai; Charles H Fraga; Michael Tagen; Paula Schaiquevich; Nikolaus Hagedorn; Clinton F Stewart
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-04-24       Impact factor: 3.205

Review 10.  High-performance liquid chromatography-tandem mass spectrometry in the identification and determination of phase I and phase II drug metabolites.

Authors:  M Holcapek; L Kolárová; M Nobilis
Journal:  Anal Bioanal Chem       Date:  2008-03-15       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.