Presentation of floating mass transducer and Vibroplasty couplers on CT and cone beam CT.

Robert Mlynski1, Thi Dao Nguyen, Stefan K Plontke, Sabrina Kösling.   

Abstract

Various titanium coupling elements, Vibroplasty Couplers, maintaining the attachment of the Floating Mass Transducer (FMT) of the active middle ear implant Vibrant Soundbridge (VSB) to the round window, the stapes suprastructure or the stapes footplate are in use to optimally transfer energy from the FMT to the inner ear fluids. In certain cases it is of interest to radiologically verify the correct position of the FMT coupler assembly. The imaging appearance of FMT connected to these couplers, however, is not well known. The aim of this study was to present the radiological appearance of correctly positioned Vibroplasty Couplers together with the FMT using two different imaging techniques. Vibroplasty Couplers were attached to the FMT of a Vibrant Soundbridge and implanted in formalin fixed human temporal bones. Five FMT coupler assemblies were implanted in different positions: conventionally to the incus, a Bell-Coupler, a CliP-Coupler, a Round Window-Coupler and an Oval Window-Coupler. High spatial resolution imaging with Multi-Detector CT (MDCT) and Cone Beam CT (CBCT) was performed in each specimen. Images were blind evaluated by two radiologists on a visual basis. Middle ear details, identification of FMT and coupler, position of FMT coupler assembly and artefacts were assessed. CBCT showed a better spatial resolution and a higher visual image quality than MDCT, but there was no significant advantage over MDCT in delineating the structures or the temporal bone of the FMT Coupler assemblies. The FMT with its coupler element could be clearly identified in the two imaging techniques. The correct positioning of the FMT and all types of couplers could be demonstrated. Both methods, MDCT and CBCT, are appropriate methods for postoperative localization of FMT in combination with Vibroplasty Couplers and for verifying their correct position. If CBCT is available, this method is recommended due to the better spatial resolution and less metal artifacts.

Entities:  

Mesh:

Year:  2013        PMID: 23529745     DOI: 10.1007/s00405-013-2457-5

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  19 in total

1.  Flat panel CT following stapes prosthesis insertion: an experimental and clinical study.

Authors:  K Zaoui; J Kromeier; M Neudert; C C Boedeker; T Zahnert; R Laszig; C Offergeld
Journal:  Eur Radiol       Date:  2011-12-08       Impact factor: 5.315

2.  Round window vibroplasty: long-term results.

Authors:  Klaus Böheim; Robert Mlynski; Thomas Lenarz; Max Schlögel; Rudolf Hagen
Journal:  Acta Otolaryngol       Date:  2012-07-10       Impact factor: 1.494

3.  Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study.

Authors:  Afshin Teymoortash; Stella Hamzei; Tobias Murthum; Behfar Eivazi; Ingo Kureck; Jochen A Werner
Journal:  Surg Radiol Anat       Date:  2010-08-13       Impact factor: 1.246

4.  The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens.

Authors:  Thiemo Kurzweg; Carsten V Dalchow; Martin Bremke; Omid Majdani; Ingo Kureck; Reinald Knecht; Jochen A Werner; Afshin Teymoortash
Journal:  Ear Hear       Date:  2010-06       Impact factor: 3.570

5.  The vibrant soundbridge for conductive and mixed hearing losses: European multicenter study results.

Authors:  W-D Baumgartner; K Böheim; R Hagen; J Müller; T Lenarz; S Reiss; M Schlögel; R Mlynski; H Mojallal; V Colletti; J Opie
Journal:  Adv Otorhinolaryngol       Date:  2010-07-05

6.  Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses.

Authors:  Alessandro Bozzato; Tobias Struffert; Victoria Hertel; Heinrich Iro; Joachim Hornung
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

7.  Cone-beam volumetric tomography for applications in the temporal bone.

Authors:  Richard T Penninger; Tanya S Tavassolie; John P Carey
Journal:  Otol Neurotol       Date:  2011-04       Impact factor: 2.311

8.  A new vibroplasty coupling technique as a treatment for conductive and mixed hearing losses: a report of 4 cases.

Authors:  Alexander M Huber; Robert Mlynski; Joachim Müller; Norbert Dillier; David Holzmann; Mario D Wolframm; Rudolf Hagen
Journal:  Otol Neurotol       Date:  2012-06       Impact factor: 2.311

9.  Congenital aural atresia treated with floating mass transducer on the round window: 5 years of imaging experience.

Authors:  M Barillari; R Cerini; M Carner; C Cacciatori; F Spagnolli; N Cardobi; M Mandalà; L Colletti; V Colletti; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2011-11-17       Impact factor: 3.469

10.  Cartilage 'shoe': a new technique for stabilisation of titanium total ossicular replacement prosthesis at centre of stapes footplate.

Authors:  D Beutner; J C Luers; K B Huttenbrink
Journal:  J Laryngol Otol       Date:  2008-05-19       Impact factor: 1.469

View more
  4 in total

1.  Hearing rehabilitation with single-stage bilateral vibroplasty in a child with Franceschetti syndrome.

Authors:  Sona Sargsyan; Torsten Rahne; Sabrina Kösling; Gerburg Eichler; Stefan K Plontke
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-02-07       Impact factor: 2.503

2.  [New clinical applications for laser Doppler vibrometry in otology].

Authors:  T Strenger; M Brandstetter; T Stark; F Böhnke
Journal:  HNO       Date:  2018-04       Impact factor: 1.284

3.  Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study.

Authors:  T D Nguyen; S Kösling; R Mlynski; S K Plontke
Journal:  Eur Radiol       Date:  2016-03-30       Impact factor: 5.315

Review 4.  Use of cone beam computed tomography in the diagnosis of superior semicircular canal dehiscence.

Authors:  Ilson Sepúlveda; Thomas Schmidt; Enrique Platín
Journal:  J Clin Imaging Sci       Date:  2014-09-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.