Literature DB >> 20706719

Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study.

Afshin Teymoortash1, Stella Hamzei, Tobias Murthum, Behfar Eivazi, Ingo Kureck, Jochen A Werner.   

Abstract

PURPOSE: The aim of the present study was to analyze the diagnostic value of some temporal bone structures, e.g., ossicular chain, with digital volume tomography (DVT) compared with computed tomography (CT).
METHODS: Radiological imaging for presentation structures of the temporal bone were performed by DVT and CT. Axial and coronal scans in vitro examinations were performed in 38 human temporal bones. 43 structures were defined. The frequency of visualization of these anatomic structures were studied and statistically analyzed.
RESULTS: In the present study there was a higher significance of identified structures in DVT. In 15 (34.9%) temporal bone specimens defined structures were found equally in DVT and CT scans of axial images and 12 (27.9%) of coronal images. However, 9 structures (20.1%) of axial scans and 5 structures (11.6%) of coronal scans could be identified statistically significantly (P < 0.05) more often in DVT than in CT.
CONCLUSION: Anatomical structures of the temporal bone can be identified in higher significance in DVT than in CT scans.

Entities:  

Mesh:

Year:  2010        PMID: 20706719     DOI: 10.1007/s00276-010-0713-6

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  23 in total

1.  A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine.

Authors:  Koji Hashimoto; Yoshinori Arai; Kazuo Iwai; Masao Araki; Shoji Kawashima; Masaaki Terakado
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2003-03

2.  Analysis of clustered matched-pair data.

Authors:  Valerie L Durkalski; Yuko Y Palesch; Stuart R Lipsitz; Philip F Rust
Journal:  Stat Med       Date:  2003-08-15       Impact factor: 2.373

3.  High-resolution flat-panel volume-CT of temporal bone--part 1: axial preoperative anatomy.

Authors:  Soenke H Bartling; Vershalee Shukla; Hartmut Becker; Thomas J Brady; Anne Hayman; Rajiv Gupta
Journal:  J Comput Assist Tomogr       Date:  2005 May-Jun       Impact factor: 1.826

4.  Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study.

Authors:  Miet Loubele; Frederik Maes; Filip Schutyser; Guy Marchal; Reinhilde Jacobs; Paul Suetens
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-04-21

Review 5.  Advances in skull base imaging.

Authors:  Colin L W Driscoll; John I Lane
Journal:  Otolaryngol Clin North Am       Date:  2007-06       Impact factor: 3.346

Review 6.  Conebeam CT of the head and neck, part 1: physical principles.

Authors:  A C Miracle; S K Mukherji
Journal:  AJNR Am J Neuroradiol       Date:  2009-05-13       Impact factor: 3.825

7.  Cone-beam computed tomography: a new method for imaging of the temporal bone.

Authors:  L I Peltonen; A A Aarnisalo; Y Käser; M K Kortesniemi; S Robinson; A Suomalainen; J Jero
Journal:  Acta Radiol       Date:  2009-06       Impact factor: 1.990

8.  Rotational tomography in cochlear implant patients: a new tool for quality control of the electrode position.

Authors:  A Aschendorff; R Kubalek; A Bink; F E Zanella; A Hochmuth; M Schumacher; T Klenzner; R Laszig
Journal:  Cochlear Implants Int       Date:  2004-09

9.  The technique of direct multiplanar high resolution CT of the temporal bone.

Authors:  F W Zonneveld
Journal:  Neurosurg Rev       Date:  1985       Impact factor: 3.042

10.  Imaging procedures in cochlear implant patients--evaluation of different radiological techniques.

Authors:  A Aschendorff; R Kubalek; A Hochmuth; A Bink; C Kurtz; P Lohnstein; T Klenzner; R Laszig
Journal:  Acta Otolaryngol Suppl       Date:  2004-05
View more
  11 in total

1.  Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT).

Authors:  C Güldner; S Wiegand; R Weiss; S Bien; A Sesterhenn; A Teymoortash; I Diogo
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-07-30       Impact factor: 2.503

2.  Visualization of anatomy in normal and pathologic middle ears by cone beam CT.

Authors:  Christian Güldner; Isabell Diogo; Eva Bernd; Stephanie Dräger; Magis Mandapathil; Afshin Teymoortash; Hesham Negm; Thomas Wilhelm
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-10-17       Impact factor: 2.503

3.  Presentation of floating mass transducer and Vibroplasty couplers on CT and cone beam CT.

Authors:  Robert Mlynski; Thi Dao Nguyen; Stefan K Plontke; Sabrina Kösling
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-03-26       Impact factor: 2.503

4.  [Visualization of subtle temporal bone structures. Comparison of cone beam CT and MDCT].

Authors:  M K Pein; S Brandt; S K Plontke; S Kösling
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

5.  Diagnostic performance of reformatted isotropic thin-section helical CT images in the detection of superior semicircular canal dehiscence.

Authors:  Gianvincenzo Sparacia; Alberto Iaia
Journal:  Neuroradiol J       Date:  2017-01-01

6.  Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study.

Authors:  T D Nguyen; S Kösling; R Mlynski; S K Plontke
Journal:  Eur Radiol       Date:  2016-03-30       Impact factor: 5.315

7.  Cone-Beam CT Compared to Multi-Slice CT for the Diagnostic Analysis of Conductive Hearing Loss: A Feasibility Study.

Authors:  Pieter Kemp; Jiska Van Stralen; Pim De Graaf; Erwin Berkhout; Pepijn Van Horssen; Paul Merkus
Journal:  J Int Adv Otol       Date:  2020-08       Impact factor: 1.017

8.  Visualisation of the Bonebridge by means of CT and CBCT.

Authors:  Christian Güldner; Julia Heinrichs; Rainer Weiß; Annette Paula Zimmermann; Benjamin Dassinger; Siegfried Bien; Jochen Alfred Werner; Isabell Diogo
Journal:  Eur J Med Res       Date:  2013-09-03       Impact factor: 2.175

Review 9.  Use of cone beam computed tomography in the diagnosis of superior semicircular canal dehiscence.

Authors:  Ilson Sepúlveda; Thomas Schmidt; Enrique Platín
Journal:  J Clin Imaging Sci       Date:  2014-09-23

10.  Intratympanic application of triamcinolone in sudden hearing loss-radiologic anatomy in cone beam CT and its' correlation to clinical outcome.

Authors:  Willi Roßberg; Friedrich Goetz; Max Eike Timm; Thomas Lenarz; Victor Helmstaedter
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-03-23       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.