Literature DB >> 18485257

Cartilage 'shoe': a new technique for stabilisation of titanium total ossicular replacement prosthesis at centre of stapes footplate.

D Beutner1, J C Luers, K B Huttenbrink.   

Abstract

OBJECTIVES: After tympanoplasty using a total ossicular replacement prosthesis, many unsatisfactory hearing results are due to dislocation of the prosthesis.
MATERIAL AND METHODS: We developed a cartilage guide for stabilising the total ossicular replacement prosthesis in the oval window niche. An oval-shaped piece of cartilage measuring 2.5 x 3.5 mm with a central hole was precisely punched out of a thin cartilage plate. The cartilage was placed in the oval niche, and its hole centred the prosthesis on the stapes footplate.
RESULTS: Hearing results in 52 patients confirmed acoustically the effectiveness of this method of total ossicular replacement prosthesis stabilisation on the stapes footplate. Subsequent 'second-look' surgery revealed stable ingrowth of the cartilage 'shoe' into the oval niche.
CONCLUSION: Such a cartilage shoe might address one of the causes of unsatisfactory hearing following ossicular chain reconstruction with a total ossicular replacement prosthesis.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18485257     DOI: 10.1017/S0022215108002545

Source DB:  PubMed          Journal:  J Laryngol Otol        ISSN: 0022-2151            Impact factor:   1.469


  8 in total

1.  An innovative way of stabilising a titanium total ossicular replacement prosthesis.

Authors:  G Kumar; Z Andreou; J S Virk; A Owa
Journal:  Ann R Coll Surg Engl       Date:  2014-11       Impact factor: 1.891

2.  Anatomic features of the fetal round and oval windows, and their relations with the tympanic nerve.

Authors:  Orhan Beger; Yusuf Vayisoğlu; Onurhan Güven; Saliha Seda Adanır; Pourya Taghipour; Salim Çakır; Oykut Dağtekin; Derya Ümit Talas
Journal:  Surg Radiol Anat       Date:  2021-01-12       Impact factor: 1.246

3.  Presentation of floating mass transducer and Vibroplasty couplers on CT and cone beam CT.

Authors:  Robert Mlynski; Thi Dao Nguyen; Stefan K Plontke; Sabrina Kösling
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-03-26       Impact factor: 2.503

4.  Anatomic variability of oval window as pertaining to stapes surgery.

Authors:  Anjali Singal; Daisy Sahni; Tulika Gupta; Anjali Aggarwal; Ashok Kumar Gupta
Journal:  Surg Radiol Anat       Date:  2019-09-23       Impact factor: 1.246

5.  Oval Window Size and Shape: a Micro-CT Anatomical Study With Considerations for Stapes Surgery.

Authors:  Matthew J Zdilla; Janusz Skrzat; Magdalena Kozerska; Bartosz Leszczyński; Jacek Tarasiuk; Sebastian Wroński
Journal:  Otol Neurotol       Date:  2018-06       Impact factor: 2.311

6.  Audiological Results of Total Ossicular Replacement Prosthesis with Cartilage Shoe Technique.

Authors:  Hacı Kaplankıran; Mehmet Emrah Ceylan; Gökçe Aksoy Yıldırım; Gözde Ceylan; Abdullah Dalğıç; Levent Olgun
Journal:  Turk Arch Otorhinolaryngol       Date:  2018-06-01

7.  Passive and active middle ear implants.

Authors:  Dirk Beutner; Karl-Bernd Hüttenbrink
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2011-03-10

8.  Auditory effects of autologous fat graft for TORP stabilization in the middle ear: a cadaveric study.

Authors:  Margaret Aron; Thomas G Landry; Manohar Bance
Journal:  J Otolaryngol Head Neck Surg       Date:  2018-02-17
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.