Literature DB >> 22160168

Flat panel CT following stapes prosthesis insertion: an experimental and clinical study.

K Zaoui1, J Kromeier, M Neudert, C C Boedeker, T Zahnert, R Laszig, C Offergeld.   

Abstract

OBJECTIVES: Anatomical information of the middle and inner ear is becoming increasingly important in post-operative evaluation especially after stapesplasty with unsuccessful improvement of the air-bone gap (ABG). So far computed tomography (CT) has been the first choice for detection of reasons for recurrent hearing loss. CT has the disadvantage of metal-induced artefacts after insertion of middle ear implants and of a relatively high irradiation dose.
METHODS: Flat panel CT (fpCT) was performed in three temporal bone specimen after experimental insertion of different stapes prostheses, aiming to validate the accuracy of fpCT of the middle and inner ear. Additionally, 28 consecutive patients, supplied with different stapes prostheses underwent post-operative fpCT to compare the pre- and post-operative hearing results with the determined prosthesis position in the middle and inner ear.
RESULTS: In all cases, fpCT showed a statistically significant correlation between hearing improvement and prosthesis position. This technique provided detailed post-operative information of the implant position in patients and temporal bone specimen.
CONCLUSIONS: The new imaging technique of fpCT allows the immediate and almost artefact-free evaluation of surgical results following stapesplasty. Further benefits are a lower irradiation dose and higher isovolumetric resolution compared with standard CT. KEY POINTS: Flat panel computed tomography (fpCT) helps otosurgeons design precise stapes protheses. fpCT allows a prediction of the postoperative hearing outcome in patients. fpCT is an adequate imaging technique for immediate postoperative quality control. Postoperative management of patients with prosthesis-related complications is more appropriate.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22160168     DOI: 10.1007/s00330-011-2317-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

Review 1.  CT and MR imaging after middle ear surgery.

Authors:  S Kösling; F Bootz
Journal:  Eur J Radiol       Date:  2001-11       Impact factor: 3.528

2.  3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images.

Authors:  T Rodt; P Ratiu; H Becker; S Bartling; D F Kacher; M Anderson; F A Jolesz; R Kikinis
Journal:  Neuroradiology       Date:  2002-08-07       Impact factor: 2.804

3.  General history of stapedectomy.

Authors:  Rudolf Häusler
Journal:  Adv Otorhinolaryngol       Date:  2007

4.  Rotational tomography of the normal and reconstructed middle ear in temporal bones: an experimental study.

Authors:  Ch Offergeld; J Kromeier; A Aschendorff; W Maier; Th Klenzner; Th Beleites; Th Zahnert; J Schipper; R Laszig
Journal:  Eur Arch Otorhinolaryngol       Date:  2006-10-18       Impact factor: 2.503

5.  Hearing gain after stapedotomy, partial platinectomy, or total stapedectomy for otosclerosis.

Authors:  C W Cremers; J M Beusen; P L Huygen
Journal:  Ann Otol Rhinol Laryngol       Date:  1991-12       Impact factor: 1.547

6.  Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses.

Authors:  Alessandro Bozzato; Tobias Struffert; Victoria Hertel; Heinrich Iro; Joachim Hornung
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

7.  [Identification of middle ear implants in high-resolution computerized tomography].

Authors:  G Oberascher; M Grobovschek
Journal:  Laryngol Rhinol Otol (Stuttg)       Date:  1988-01

8.  Experimental investigation of rotational tomography in reconstructed middle ears with clinical implications.

Authors:  Christian Offergeld; Jan Kromeier; Saumil N Merchant; Nicoloz Lasurashvili; Marcus Neudert; Matthias Bornitz; Roland Laszig; Thomas Zahnert
Journal:  Hear Res       Date:  2009-12-05       Impact factor: 3.208

9.  [Significance of computed tomography evaluation before revision stapes surgery].

Authors:  C Röösli; A Hoffmann; T Treumann; T E Linder
Journal:  HNO       Date:  2008-09       Impact factor: 1.284

10.  MRI Scanners and the Stapes Prosthesis.

Authors:  Michael H Fritsch
Journal:  Otol Neurotol       Date:  2007-09       Impact factor: 2.311

View more
  4 in total

1.  [Quality control following reconstructive middle ear surgery: from bench to bedside].

Authors:  C Offergeld
Journal:  HNO       Date:  2013-12       Impact factor: 1.284

2.  Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients.

Authors:  K Zaoui; J Kromeier; M Neudert; T Beleites; T Zahnert; R Laszig; C Offergeld
Journal:  Eur Radiol       Date:  2013-11-26       Impact factor: 5.315

3.  Presentation of floating mass transducer and Vibroplasty couplers on CT and cone beam CT.

Authors:  Robert Mlynski; Thi Dao Nguyen; Stefan K Plontke; Sabrina Kösling
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-03-26       Impact factor: 2.503

4.  [Visualization of subtle temporal bone structures. Comparison of cone beam CT and MDCT].

Authors:  M K Pein; S Brandt; S K Plontke; S Kösling
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

  4 in total