Literature DB >> 22592941

High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T.

Ha-Kyu Jeong1, John C Gore, Adam W Anderson.   

Abstract

The combination of parallel imaging with partial Fourier acquisition has greatly improved the performance of diffusion-weighted single-shot EPI and is the preferred method for acquisitions at low to medium magnetic field strength such as 1.5 or 3 T. Increased off-resonance effects and reduced transverse relaxation times at 7 T, however, generate more significant artifacts than at lower magnetic field strength and limit data acquisition. Additional acceleration of k-space traversal using a multishot approach, which acquires a subset of k-space data after each excitation, reduces these artifacts relative to conventional single-shot acquisitions. However, corrections for motion-induced phase errors are not straightforward in accelerated, diffusion-weighted multishot EPI because of phase aliasing. In this study, we introduce a simple acquisition and corresponding reconstruction method for diffusion-weighted multishot EPI with parallel imaging suitable for use at high field. The reconstruction uses a simple modification of the standard sensitivity-encoding (SENSE) algorithm to account for shot-to-shot phase errors; the method is called image reconstruction using image-space sampling function (IRIS). Using this approach, reconstruction from highly aliased in vivo image data using 2-D navigator phase information is demonstrated for human diffusion-weighted imaging studies at 7 T. The final reconstructed images show submillimeter in-plane resolution with no ghosts and much reduced blurring and off-resonance artifacts.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22592941      PMCID: PMC3424313          DOI: 10.1002/mrm.24320

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  42 in total

1.  Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system.

Authors:  R Bammer; R Stollberger; M Augustin; J Simbrunner; H Offenbacher; H Kooijman; S Ropele; P Kapeller; P Wach; F Ebner; F Fazekas
Journal:  Radiology       Date:  1999-06       Impact factor: 11.105

2.  Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging.

Authors:  Chunlei Liu; Roland Bammer; Dong-Hyun Kim; Michael E Moseley
Journal:  Magn Reson Med       Date:  2004-12       Impact factor: 4.668

3.  Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.

Authors:  Chunlei Liu; Michael E Moseley; Roland Bammer
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

4.  Propeller EPI in the other direction.

Authors:  Stefan Skare; Rexford D Newbould; Dave B Clayton; Roland Bammer
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

5.  Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes.

Authors:  K Butts; A de Crespigny; J M Pauly; M Moseley
Journal:  Magn Reson Med       Date:  1996-05       Impact factor: 4.668

6.  Characterization of and correction for eddy current artifacts in echo planar diffusion imaging.

Authors:  P Jezzard; A S Barnett; C Pierpaoli
Journal:  Magn Reson Med       Date:  1998-05       Impact factor: 4.668

7.  Phase errors in multi-shot echo planar imaging.

Authors:  D A Feinberg; K Oshio
Journal:  Magn Reson Med       Date:  1994-10       Impact factor: 4.668

8.  Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke.

Authors:  K Butts; J Pauly; A de Crespigny; M Moseley
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

9.  Navigated diffusion imaging of normal and ischemic human brain.

Authors:  A J de Crespigny; M P Marks; D R Enzmann; M E Moseley
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

10.  Nonlinear phase correction of navigated multi-coil diffusion images.

Authors:  David Atkinson; Serena Counsell; Joseph V Hajnal; Philip G Batchelor; Derek L G Hill; David J Larkman
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

View more
  37 in total

1.  POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.

Authors:  Mei-Lan Chu; Hing-Chiu Chang; Hsiao-Wen Chung; Trong-Kha Truong; Mustafa R Bashir; Nan-kuei Chen
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

2.  Three-dimensional simultaneous brain T1 , T2 , and ADC mapping with MR Multitasking.

Authors:  Sen Ma; Christopher T Nguyen; Fei Han; Nan Wang; Zixin Deng; Nader Binesh; Franklin G Moser; Anthony G Christodoulou; Debiao Li
Journal:  Magn Reson Med       Date:  2019-11-25       Impact factor: 4.668

3.  High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS).

Authors:  Kawin Setsompop; Qiuyun Fan; Jason Stockmann; Berkin Bilgic; Susie Huang; Stephen F Cauley; Aapo Nummenmaa; Fuyixue Wang; Yogesh Rathi; Thomas Witzel; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

4.  Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstruction.

Authors:  Berkin Bilgic; Itthi Chatnuntawech; Mary Kate Manhard; Qiyuan Tian; Congyu Liao; Siddharth S Iyer; Stephen F Cauley; Susie Y Huang; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-05-20       Impact factor: 4.668

5.  Improved diffusion tensor imaging of the optic nerve using multishot two-dimensional navigated acquisitions.

Authors:  Ha-Kyu Jeong; Blake E Dewey; Jane A T Hirtle; Patrick Lavin; Subramaniam Sriram; Siddharama Pawate; John C Gore; Adam W Anderson; Hakmook Kang; Seth A Smith
Journal:  Magn Reson Med       Date:  2014-09-26       Impact factor: 4.668

6.  Sequence design and evaluation of the reproducibility of water-selective diffusion-weighted imaging of the breast at 3 T.

Authors:  He Zhu; Lori R Arlinghaus; Jennifer G Whisenant; Ming Li; John C Gore; Thomas E Yankeelov
Journal:  NMR Biomed       Date:  2014-07-01       Impact factor: 4.044

7.  3D-MB-MUSE: A robust 3D multi-slab, multi-band and multi-shot reconstruction approach for ultrahigh resolution diffusion MRI.

Authors:  Iain P Bruce; Hing-Chiu Chang; Christopher Petty; Nan-Kuei Chen; Allen W Song
Journal:  Neuroimage       Date:  2017-07-18       Impact factor: 6.556

8.  Role of coronal high-resolution diffusion-weighted imaging in acute optic neuritis: a comparison with axial orientation.

Authors:  Ping Lu; Yan Sha; Hailin Wan; Feng Wang; Guohong Tian
Journal:  Neuroradiology       Date:  2017-06-24       Impact factor: 2.804

9.  Correction of geometric distortion in Propeller echo planar imaging using a modified reversed gradient approach.

Authors:  Hing-Chiu Chang; Tzu-Chao Chuang; Yi-Ru Lin; Fu-Nien Wang; Teng-Yi Huang; Hsiao-Wen Chung
Journal:  Quant Imaging Med Surg       Date:  2013-04

10.  High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with B 1 + and T1 corrections and integrated ΔB0 /Rx shim array.

Authors:  Congyu Liao; Jason Stockmann; Qiyuan Tian; Berkin Bilgic; Nicolas S Arango; Mary Kate Manhard; Susie Y Huang; William A Grissom; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-08-01       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.