Literature DB >> 10453411

3D contrast-enhanced MR angiography using fluoroscopic triggering and an elliptical centric view order.

S J Riederer1, S B Fain, D G Kruger, R F Busse.   

Abstract

Although a variety of timing techniques and data acquisition strategies have been used for three-dimensional contrast-enhanced MR angiography, many are still limited by inadequate overall reliability, limited spatial resolution, or complexity. A technique is presented in this work in which contrast arrival is detected in the targetted vasculature in real time using MR fluoroscopy. Upon detection the operator triggers a 3D MR angiographic acquisition which uses an elliptical centric view order. It is shown that the view order intrinsically provides a high degree of venous suppression which in turn allows acquisition times of 30 seconds or longer, permitting high spatial resolution. The reliability of fluoroscopic triggering in bolus detection is shown to be over 90%. The technique provides high quality contrast-enhanced MR angiograms for many vascular regions.

Mesh:

Year:  1999        PMID: 10453411     DOI: 10.1023/a:1006122514980

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  22 in total

1.  Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging.

Authors:  A H Wilman; S J Riederer
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

2.  Cardiac magnetic resonance fluoroscopy.

Authors:  J P Debbins; S J Riederer; P J Rossman; R C Grimm; J P Felmlee; J F Breen; R L Ehman
Journal:  Magn Reson Med       Date:  1996-10       Impact factor: 4.668

3.  Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector.

Authors:  J P Earls; N M Rofsky; D R DeCorato; G A Krinsky; J C Weinreb
Journal:  Radiology       Date:  1996-12       Impact factor: 11.105

4.  Contrast-enhanced MR angiography. Methods, limitations and possibilities.

Authors:  M Kouwenhoven
Journal:  Acta Radiol Suppl       Date:  1997

5.  Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography.

Authors:  T K Foo; M Saranathan; M R Prince; T L Chenevert
Journal:  Radiology       Date:  1997-04       Impact factor: 11.105

6.  Optimization of contrast timing for breath-hold three-dimensional MR angiography.

Authors:  T F Hany; G C McKinnon; D A Leung; T Pfammatter; J F Debatin
Journal:  J Magn Reson Imaging       Date:  1997 May-Jun       Impact factor: 4.813

7.  MR fluoroscopy: technical feasibility.

Authors:  S J Riederer; T Tasciyan; F Farzaneh; J N Lee; R C Wright; R J Herfkens
Journal:  Magn Reson Med       Date:  1988-09       Impact factor: 4.668

8.  Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches.

Authors:  M R Prince; D L Narasimham; J C Stanley; T L Chenevert; D M Williams; M V Marx; K J Cho
Journal:  Radiology       Date:  1995-12       Impact factor: 11.105

9.  Fast MR angiography of the aortoiliac arteries and arteries of the lower extremity: value of bolus-enhanced, whole-volume subtraction technique.

Authors:  P C Douek; D Revel; S Chazel; B Falise; J Villard; M Amiel
Journal:  AJR Am J Roentgenol       Date:  1995-08       Impact factor: 3.959

10.  Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries.

Authors:  G A Holland; L Dougherty; J P Carpenter; M A Golden; M Gilfeather; F Slossman; M D Schnall; L Axel
Journal:  AJR Am J Roentgenol       Date:  1996-04       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.