Literature DB >> 19777499

Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12).

Xin Liu1, Yi Feng, Zheng-Rong Lu, Glen Morrell, Eun-Kee Jeong.   

Abstract

A rapid method of simultaneous T(1) and T(2) measurement is presented which uses a segmented echo-planar readout with varying repetition times (TR) and echo times (TE). This method is useful in T(1) mapping for analysis of dynamic contrast enhanced MRI (DCE-MRI), where T(1) can be used to estimate contrast agent concentration. In the application of this method to dynamic imaging, the equilibrium magnetization is measured on pre-contrast images and incorporated into post-contrast T(1) calculations for improved accuracy. Simultaneous T(2) measurement allows correction of T(2) effects in the T(1) map which may occur at high contrast agent concentrations, and is performed without significant imaging time penalty. Phantom and in vivo results show the usefulness of this technique for analysis of contrast enhancement kinetics. Accurate rapid contrast agent concentration measurement may be useful for analyzing the distribution and kinetics of contrast agents or labeled pharmaceuticals.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19777499      PMCID: PMC3541052          DOI: 10.1002/nbm.1440

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  14 in total

Review 1.  In vivo monitoring of tumor angiogenesis with MR imaging.

Authors:  R C Brasch; K C Li; J E Husband; M T Keogan; M Neeman; A R Padhani; D Shames; K Turetschek
Journal:  Acad Radiol       Date:  2000-10       Impact factor: 3.173

2.  Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state.

Authors:  Sean C L Deoni; Brian K Rutt; Terry M Peters
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

Review 3.  Ultra-fast imaging.

Authors:  M S Cohen; R M Weisskoff
Journal:  Magn Reson Imaging       Date:  1991       Impact factor: 2.546

4.  Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging.

Authors:  F Farzaneh; S J Riederer; N J Pelc
Journal:  Magn Reson Med       Date:  1990-04       Impact factor: 4.668

5.  Accurate measurement of T1 in vivo in less than 3 seconds using echo-planar imaging.

Authors:  P Gowland; P Mansfield
Journal:  Magn Reson Med       Date:  1993-09       Impact factor: 4.668

6.  Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12).

Authors:  Xin Liu; Yi Feng; Zheng-Rong Lu; Glen Morrell; Eun-Kee Jeong
Journal:  NMR Biomed       Date:  2010-01       Impact factor: 4.044

7.  Breast disease: tissue characterization with Gd-DTPA enhancement profiles.

Authors:  J P Stack; O M Redmond; M B Codd; P A Dervan; J T Ennis
Journal:  Radiology       Date:  1990-02       Impact factor: 11.105

Review 8.  The role of MR imaging in carcinoma of the urinary bladder.

Authors:  J O Barentsz; S H Ruijs; S P Strijk
Journal:  AJR Am J Roentgenol       Date:  1993-05       Impact factor: 3.959

Review 9.  Dynamic contrast-enhanced MRI in clinical oncology: current status and future directions.

Authors:  Anwar R Padhani
Journal:  J Magn Reson Imaging       Date:  2002-10       Impact factor: 4.813

10.  Correlation of dynamic contrast-enhanced MR imaging with histologic tumor grade: comparison of macromolecular and small-molecular contrast media.

Authors:  H Daldrup; D M Shames; M Wendland; Y Okuhata; T M Link; W Rosenau; Y Lu; R C Brasch
Journal:  AJR Am J Roentgenol       Date:  1998-10       Impact factor: 3.959

View more
  6 in total

1.  Measuring T₂ and T₁, and imaging T₂ without spin echoes.

Authors:  G Wang; A M El-Sharkawy; W A Edelstein; M Schär; P A Bottomley
Journal:  J Magn Reson       Date:  2011-12-07       Impact factor: 2.229

2.  Single-shot T1 mapping using simultaneous acquisitions of spin- and stimulated-echo-planar imaging (2D ss-SESTEPI).

Authors:  Xianfeng Shi; Seong-Eun Kim; Eun-Kee Jeong
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

3.  Ocular pharmacokinetic study using T₁ mapping and Gd-chelate- labeled polymers.

Authors:  Xianfeng Shi; Xin Liu; Xueming Wu; Zheng-Rong Lu; S Kevin Li; Eun-Kee Jeong
Journal:  Pharm Res       Date:  2011-06-21       Impact factor: 4.200

Review 4.  Primary Multiparametric Quantitative Brain MRI: State-of-the-Art Relaxometric and Proton Density Mapping Techniques.

Authors:  Hernán Jara; Osamu Sakai; Ezequiel Farrher; Ana-Maria Oros-Peusquens; N Jon Shah; David C Alsop; Kathryn E Keenan
Journal:  Radiology       Date:  2022-08-30       Impact factor: 29.146

5.  Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12).

Authors:  Xin Liu; Yi Feng; Zheng-Rong Lu; Glen Morrell; Eun-Kee Jeong
Journal:  NMR Biomed       Date:  2010-01       Impact factor: 4.044

Review 6.  MRI in ocular drug delivery.

Authors:  S Kevin Li; Martin J Lizak; Eun-Kee Jeong
Journal:  NMR Biomed       Date:  2008-11       Impact factor: 4.044

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.