Literature DB >> 2524570

The effects of beam hardening on digital subtraction radiography.

R L Webber, A Tzukert, U Ruttimann.   

Abstract

Quantitative assessment of osseous changes attributable to periodontal disease is made possible by digital subtraction radiography. Tissues through which x rays travel to produce dental radiographs essential to this process alter the energy spectrum of the beam such that calibration errors result when densitometry is attempted using a homogeneous calibration standard such as a step wedge. The following controlled in vitro investigation evaluates the extent of such errors caused by these spectral differences, called beam hardening. Simulated osseous lesions of known size were computed densitometrically using selectively filtered radiation to produce the x-ray images. The resulting data confirm the theory and demonstrate with statistically meaningful accuracy that beam hardening can contribute a significant component of variance to absolute estimates of lesion size. They also suggest that other errors (probably attributable to low contrast) may be even more important at high peak kilovoltages.

Entities:  

Mesh:

Year:  1989        PMID: 2524570     DOI: 10.1111/j.1600-0765.1989.tb00857.x

Source DB:  PubMed          Journal:  J Periodontal Res        ISSN: 0022-3484            Impact factor:   4.419


  5 in total

1.  Evaluation of a cone beam CT artefact reduction algorithm.

Authors:  B Bechara; C A McMahan; H Geha; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-02-23       Impact factor: 2.419

2.  Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials.

Authors:  Polyane Mazucatto Queiroz; Matheus Lima Oliveira; Francisco Carlos Groppo; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Clin Oral Investig       Date:  2017-05-23       Impact factor: 3.573

3.  Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.

Authors:  B Bechara; C Alex McMahan; W S Moore; M Noujeim; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

4.  Metal artefact reduction with cone beam CT: an in vitro study.

Authors:  B B Bechara; W S Moore; C A McMahan; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-01-12       Impact factor: 2.419

5.  Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth.

Authors:  B Bechara; C A McMahan; M Noujeim; T Faddoul; W S Moore; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-04-26       Impact factor: 2.419

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.