Literature DB >> 25666446

Influence of CBCT enhancement filters on diagnosis of vertical root fractures: a simulation study in endodontically treated teeth with and without intracanal posts.

L M Ferreira1, M A P G Visconti, H A Nascimento, R R Dallemolle, G M Ambrosano, D Q Freitas.   

Abstract

OBJECTIVES: To evaluate the influence of CBCT enhancement filters on the diagnosis of vertical root fractures (VRFs) in teeth with and without metal posts.
METHODS: The crowns of 40 uniradicular human teeth were removed and all roots were prepared. 20 teeth were randomly selected, and VRFs were induced using a universal testing machine. The i-CAT (Imaging Sciences International, Hatfield, PA) CBCT was used to scan teeth with and without intracanal metal posts using the following parameters: 0.2 voxel size, 8 × 8-cm scan size and acquisition time of 26.9 s. Images were evaluated by three observers with and without the use of the following filters: S9, smooth, smooth 3 × 3, sharpen, sharpen-mild and sharpen 3 × 3.
RESULTS: Intra- and interobserver agreement ranged from poor to moderate. Images with and without CBCT filters did not show significant differences regarding the area under the receiver operating characteristic curve, as well as sensitivity (p > 0.05). As for accuracy, the sharpen-mild filter was superior to the sharpen (p = 0.03), but these filters did not differ from all others. For specificity, S9, smooth and original images were superior to sharpen (p < 0.01). Results for teeth without posts differed from those for teeth with metal posts in all cases (p < 0.05).
CONCLUSIONS: The use of enhancement filters in CBCT images has no influence on the diagnosis of VRFs in teeth with metal posts, and their use is not justified.

Entities:  

Keywords:  cone beam computed tomography; radiographic image enhancement; vertical root fracture

Mesh:

Substances:

Year:  2015        PMID: 25666446      PMCID: PMC4628497          DOI: 10.1259/dmfr.20140352

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  29 in total

1.  Influence of cone-beam computed tomography enhancement filters on diagnosis of simulated external root resorption.

Authors:  Sergio Lins de Azevedo Vaz; Taruska Ventorini Vasconcelos; Frederico Sampaio Neves; Deborah Queiroz de Freitas; Francisco Haiter-Neto
Journal:  J Endod       Date:  2011-12-06       Impact factor: 4.171

Review 2.  Diagnostic accuracy of CBCT for tooth fractures: a meta-analysis.

Authors:  Hu Long; Yang Zhou; Niansong Ye; Lina Liao; Fan Jian; Yan Wang; Wenli Lai
Journal:  J Dent       Date:  2013-12-07       Impact factor: 4.379

3.  A demographic analysis of vertical root fractures.

Authors:  Stephen Cohen; Louis H Berman; Lucia Blanco; Leif Bakland; Jay S Kim
Journal:  J Endod       Date:  2006-10-13       Impact factor: 4.171

4.  Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.

Authors:  B Bechara; C Alex McMahan; W S Moore; M Noujeim; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

5.  Impact of root fillings and posts on the diagnostic ability of three intra-oral digital radiographic systems in detecting vertical root fractures.

Authors:  H A R Nascimento; F S Neves; S L de-Azevedo-Vaz; T M Duque; G M B Ambrosano; D Q Freitas
Journal:  Int Endod J       Date:  2014-10-20       Impact factor: 5.264

6.  Comparison of conventional radiography with cone beam computed tomography for detection of vertical root fractures: an in vitro study.

Authors:  Masoud Varshosaz; Mohammad A Tavakoli; Maryam Mostafavi; Alireza A Baghban
Journal:  J Oral Sci       Date:  2010-12       Impact factor: 1.556

7.  Root fracture detection: a comparison of direct digital radiography with conventional radiography.

Authors:  S Kositbowornchai; R Nuansakul; S Sikram; S Sinahawattana; S Saengmontri
Journal:  Dentomaxillofac Radiol       Date:  2001-03       Impact factor: 2.419

8.  Detection of vertical root fractures in the presence of intracanal metallic post: a comparison between periapical radiography and cone-beam computed tomography.

Authors:  Rafael Binato Junqueira; Francielle Silvestre Verner; Celso Neiva Campos; Karina Lopes Devito; Antônio Márcio Resende do Carmo
Journal:  J Endod       Date:  2013-10-13       Impact factor: 4.171

9.  Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model.

Authors:  Ann Wenzel; Fransisco Haiter-Neto; Morten Frydenberg; Lise-Lotte Kirkevang
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-10-28

10.  A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth.

Authors:  E Brady; F Mannocci; J Brown; R Wilson; S Patel
Journal:  Int Endod J       Date:  2013-12-11       Impact factor: 5.264

View more
  11 in total

1.  Application of image processing techniques to aid in the detection of vertical root fractures in digital periapical radiography.

Authors:  Lucas Exposto Soares; Deborah Queiroz Freitas; Kaique Leite de Lima; Lorena Rosa Silva; Fernanda Paula Yamamoto-Silva; Marcelo Andrade da Costa Vieira
Journal:  Clin Oral Investig       Date:  2021-02-05       Impact factor: 3.573

2.  Imaginological characterization of multiple myeloma lesions of the jaws through cone-beam computed tomography.

Authors:  Thaiza Gonçalves Rocha; Édila Figuerêdo Feitosa; Ângelo Maiolino; Roberto José Pessoa de Magalhães Filho; Fábio Ribeiro Guedes; Sandra Regina Torres; Maria Augusta Visconti
Journal:  Oral Radiol       Date:  2019-06-19       Impact factor: 1.852

3.  Comparing cone-beam computed tomography with periapical radiography for assessing root canal obturation in vivo using microsurgical findings as validation.

Authors:  Dongzhe Song; Lan Zhang; Wei Zhou; Qinghua Zheng; Xingyu Duan; Xuedong Zhou; Dingming Huang
Journal:  Dentomaxillofac Radiol       Date:  2017-03-23       Impact factor: 2.419

4.  Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts.

Authors:  Deborah Queiroz Freitas; Rocharles Cavalcante Fontenele; Eduarda Helena Leandro Nascimento; Taruska Ventorini Vasconcelos; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2018-06-27       Impact factor: 2.419

5.  Difference in the artefacts production and the performance of the metal artefact reduction (MAR) tool between the buccal and lingual cortical plates adjacent to zirconium dental implant.

Authors:  Eduarda Helena Leandro Nascimento; Rocharles Cavalcante Fontenele; Gustavo Machado Santaella; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2019-07-10       Impact factor: 2.419

6.  Comparison of the expression of the volumetric alteration artifact in cylindrical and triangular fields of view in two cone-beam computed tomography devices.

Authors:  Deivi Cascante-Sequeira; Fernanda Coelho-Silva; Lucas P Lopes Rosado; Deborah Queiroz Freitas; Sergio Lins de-Azevedo-Vaz; Francisco Haiter-Neto
Journal:  Clin Oral Investig       Date:  2021-07-29       Impact factor: 3.606

7.  Influence of enhancement filters in apical bone loss measurement: A cone-beam computed tomography study.

Authors:  Emerson-Tavares de Sousa; Mayara-Abreu Pinheiro; Patrícia-Pereira Maciel; Marcelo-Augusto-Oliveira Sales
Journal:  J Clin Exp Dent       Date:  2017-04-01

8.  Influence of voxel size on cone-beam computed tomography-based detection of vertical root fractures in the presence of intracanal metallic posts.

Authors:  Fernanda Paula Yamamoto-Silva; Claudeir Felipe de Oliveira Siqueira; Maria Alves Garcia Santos Silva; Rodrigo Borges Fonseca; Ananda Amaral Santos; Carlos Estrela; Brunno Santos de Freitas Silva
Journal:  Imaging Sci Dent       Date:  2018-09-18

9.  Detection of Vertical Root Fractures Using Cone-Beam Computed Tomography in the Presence and Absence of Gutta-Percha.

Authors:  Ehsan Hekmatian; Mitra Karbasi Kheir; Hossein Fathollahzade; Mahnaz Sheikhi
Journal:  ScientificWorldJournal       Date:  2018-07-09

10.  Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters.

Authors:  Katharina Alves Rabelo; Yuri Wanderley Cavalcanti; Martina Gerlane de Oliveira Pinto; Saulo Leonardo Sousa Melo; Paulo Sérgio Flores Campos; Luciana Soares de Andrade Freitas Oliveira; Daniela Pita de Melo
Journal:  Imaging Sci Dent       Date:  2017-09-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.