Literature DB >> 2352007

Effect of anemia on pulse oximeter accuracy at low saturation.

J W Severinghaus1, S O Koh.   

Abstract

A retrospective evaluation of simultaneous tests of oximeters of various manufacturers in volunteer subjects disclosed greater errors at low saturations in subjects with low hemoglobin (Hb) concentrations. Forty-three pulse oximeters of 12 manufacturers studied over a period of 10 months showed that, at a mean arterial oxygen saturation (SaO2) level of 54.5%, as Hb concentration fell, average pulse oximeter (SpO2) bias increased approximately linearly from 0 at Hb greater than 14 g/dl to about -14% at 8 less than Hb less than 9 g/dl. At SaO2 = 53.6%, the mean bias (SaO2--SpO2) of 13 oximeters of 5 manufacturers averaged -15.0% (n = 43) in a subject with Hb = 8 g/dl, but -6.4% (n = 390) in nonanemic subjects. The additional bias in the anemic subject increased with desaturation. It was 0.13% at SaO2 = 98.5% (n = 13), -1.31% at 87.5% (n = 38), -2.71% at 75.1% (n = 38), -5.18% at 61.3% (n = 26), and -9.95% at 53.6% (n = 41); n is the product of the number of oximeters and number of tests in each saturation range. The instruments that showed the greatest errors at low saturations in nonanemic subjects also showed the greatest additional errors associated with anemia (the range between manufacturers of anemic incremental error at about 53% being from -3.2 to -14.5%) and conformed well to the relationship bias (anemic) = 1.35 x bias (normal) -8.18% (r = 0.94; Sy.x = 3.3%). The error due to anemia was zero at 97% SaO2 and became evident when SaO2 fell below 75%.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2352007     DOI: 10.1007/bf02828282

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  2 in total

1.  Errors in 14 pulse oximeters during profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh; S O Koh
Journal:  J Clin Monit       Date:  1989-04

2.  Accuracy of response of six pulse oximeters to profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

  2 in total
  9 in total

Review 1.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

2.  Pulse oximetry in severe anaemia.

Authors:  T Ramsing; J Rosenberg
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

3.  Central venous pulsations associated with a falsely low oxygen saturation measured by pulse oximetry.

Authors:  H M Sami; B S Kleinman; V A Lonchyna
Journal:  J Clin Monit       Date:  1991-10

4.  The role of pulse oximetry in chiropractic practice: a rationale for its use.

Authors:  Michael W Hall; Anne M Jensen
Journal:  J Chiropr Med       Date:  2012-06

5.  Pulse oximeter signal at various blood flow conditions in an in vitro model.

Authors:  L G Lindberg; M Vegfors; C Lennmarken; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

6.  The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study.

Authors:  Ben J Wilson; Hamish J Cowan; Jason A Lord; Dan J Zuege; David A Zygun
Journal:  BMC Emerg Med       Date:  2010-05-05

7.  Accuracy of pulse oximetry at various haematocrits and during haemolysis in an in vitro model.

Authors:  M Vegfors; L G Lindberg; P A Oberg; C Lennmarken
Journal:  Med Biol Eng Comput       Date:  1993-03       Impact factor: 2.602

Review 8.  Rationale and limitations of the SpO2/FiO2 as a possible substitute for PaO2/FiO2 in different preclinical and clinical scenarios.

Authors:  Eduardo Butturini de Carvalho; Thiago Ravache Sobreira Leite; Raquel Ferreira de Magalhães Sacramento; Paulo Roberto Loureiro do Nascimento; Cynthia Dos Santos Samary; Patrícia Rieken Macedo Rocco; Pedro Leme Silva
Journal:  Rev Bras Ter Intensiva       Date:  2022 Jan-Mar

9.  Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation?

Authors:  Gavin D Perkins; Daniel F McAuley; Simon Giles; Helen Routledge; Fang Gao
Journal:  Crit Care       Date:  2003-06-11       Impact factor: 9.097

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.