Literature DB >> 1812874

Central venous pulsations associated with a falsely low oxygen saturation measured by pulse oximetry.

H M Sami1, B S Kleinman, V A Lonchyna.   

Abstract

Venous pulsations are thought, but to our knowledge have never been demonstrated, to result in underestimation of oxygen saturation measured by pulse oximetry (SpO2); however, to our knowledge, this has never been demonstrated. A patient with ischemic cardiomyopathy requiring intra-aortic balloon counterpulsation (IABC) had to withstand a temporary cessation of IABC (period I), during which she had marked central venous pulsations and a pulse oximeter bias of -18%. After IABC was reinstituted (period II), the venous pulsations disappeared and the bias was reduced to 0%. Cardiac output, systemic vascular resistance, and temperature during both periods were comparable. Pulmonary vascular resistance, however, was much lower during period II. We postulate that the bias was caused by venous pulsations significantly contributing to the AC, or variable component, of light absorption.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1812874     DOI: 10.1007/BF01619351

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  5 in total

Review 1.  Pulse oximetry.

Authors:  K K Tremper; S J Barker
Journal:  Anesthesiology       Date:  1989-01       Impact factor: 7.892

2.  Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography.

Authors:  J M Kim; K Arakawa; K T Benson; D K Fox
Journal:  Anesth Analg       Date:  1986-12       Impact factor: 5.108

3.  Pulse oximetry during low cardiac output and hypothermia states immediately after open heart surgery.

Authors:  H Pälve; A Vuori
Journal:  Crit Care Med       Date:  1989-01       Impact factor: 7.598

4.  Pulse oximetry.

Authors:  W New
Journal:  J Clin Monit       Date:  1985-04

5.  Effect of anemia on pulse oximeter accuracy at low saturation.

Authors:  J W Severinghaus; S O Koh
Journal:  J Clin Monit       Date:  1990-04
  5 in total
  7 in total

1.  The pulse in reflectance pulse oximetry: modeling and experimental studies.

Authors:  James L Reuss; Daniel Siker
Journal:  J Clin Monit Comput       Date:  2004-08       Impact factor: 2.502

2.  Effect of peripheral vasoconstriction on pulse oximetry.

Authors:  Pekka Talke; Claudia Stapelfeldt
Journal:  J Clin Monit Comput       Date:  2006-07-14       Impact factor: 2.502

3.  The detection of peripheral venous pulsation using the pulse oximeter as a plethysmograph.

Authors:  K H Shelley; M Dickstein; S M Shulman
Journal:  J Clin Monit       Date:  1993-09

4.  Pulse Oximetry and Arterial Oxygen Saturation during Cardiopulmonary Exercise Testing.

Authors:  Mona Ascha; Anirban Bhattacharyya; Jose A Ramos; Adriano R Tonelli
Journal:  Med Sci Sports Exerc       Date:  2018-10       Impact factor: 5.411

Review 5.  Pulmonary gas exchange and acid-base balance during exercise.

Authors:  Michael K Stickland; Michael I Lindinger; I Mark Olfert; George J F Heigenhauser; Susan R Hopkins
Journal:  Compr Physiol       Date:  2013-04       Impact factor: 9.090

6.  Limitations of forehead pulse oximetry.

Authors:  J S Jørgensen; E R Schmid; V König; K Faisst; A Huch; R Huch
Journal:  J Clin Monit       Date:  1995-07

Review 7.  Sources of Inaccuracy in Photoplethysmography for Continuous Cardiovascular Monitoring.

Authors:  Jesse Fine; Kimberly L Branan; Andres J Rodriguez; Tananant Boonya-Ananta; Jessica C Ramella-Roman; Michael J McShane; Gerard L Coté
Journal:  Biosensors (Basel)       Date:  2021-04-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.