Accuracy of pulse oximetry at various haematocrits and during haemolysis in an in vitro model.

M Vegfors1, L G Lindberg, P A Oberg, C Lennmarken.   

Abstract

In situations in which it may be impossible and/or unethical to evaluate pulse oximetry in humans, an in vitro model with circulating blood may be a necessity. The main objective was to develop such an in vitro model and, in this model, validate the pulse oximetry technique at various haematocrit levels. The pulsating character of arterial blood flow in a tubing system was simulated by using a specially constructed pressure-regulated roller pump. The tubing system was designed to minimise damage to red blood cells. The pulse oximeter readings (SpO2) were compared with oxygen saturation analyses by a haemoximeter (SaO2). The pulse oximetry readings were recorded at various haematocrit levels and during haemolysis in the SaO2 range 60-100 per cent. At a haematocrit level of 41-44 per cent, there was no correlation between SaO2 and SpO2 readings. After diluting the blood with normal saline to a haematocrit of 10-11 per cent, a good correlation between SaO2 and SpO2 was found. Following haemolysis, the agreement between SaO2 and SpO2 was further improved. Using the developed in vitro model, the results indicate that the accuracy of a pulse oximeter may be dependent on the haematocrit level.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8331993     DOI: 10.1007/bf02446671

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  32 in total

1.  Effects of anemia on pulse oximetry and continuous mixed venous hemoglobin saturation monitoring in dogs.

Authors:  S Lee; K K Tremper; S J Barker
Journal:  Anesthesiology       Date:  1991-07       Impact factor: 7.892

2.  Pulse oximeter desaturation due to methemoglobinemia.

Authors:  J B Eisenkraft
Journal:  Anesthesiology       Date:  1988-02       Impact factor: 7.892

3.  Accuracy of pulse oximetry during arterial oxyhemoglobin desaturation in dogs.

Authors:  M J Sendak; A P Harris; R T Donham
Journal:  Anesthesiology       Date:  1988-01       Impact factor: 7.892

4.  Effects of intravenously administered dyes on pulse oximetry readings.

Authors:  M S Scheller; R J Unger; M J Kelner
Journal:  Anesthesiology       Date:  1986-11       Impact factor: 7.892

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Assessment of peripheral blood flow using a pulse oximeter.

Authors:  M Vegfors; B Tryggvason; F Sjöberg; C Lennmarken
Journal:  J Clin Monit       Date:  1990-01

7.  Infrared heat lamps interfere with pulse oximeters.

Authors:  T D Brooks; D A Paulus; W E Winkle
Journal:  Anesthesiology       Date:  1984-11       Impact factor: 7.892

8.  Effects of multiple scattering and peripheral circulation on arterial oxygen saturation measured with a pulse-type oximeter.

Authors:  Y Shimada; I Yoshiya; N Oka; K Hamaguri
Journal:  Med Biol Eng Comput       Date:  1984-09       Impact factor: 2.602

9.  Effect of anemia on pulse oximeter accuracy at low saturation.

Authors:  J W Severinghaus; S O Koh
Journal:  J Clin Monit       Date:  1990-04

10.  A single-blind study of pulse oximetry in children.

Authors:  C J Coté; E A Goldstein; M A Coté; D C Hoaglin; J F Ryan
Journal:  Anesthesiology       Date:  1988-02       Impact factor: 7.892

View more
  4 in total

1.  Computer analysis system of blood oxygen saturation in an animal hypoxia model.

Authors:  Y X Yang; B S Xie; Z X Zhou; J N Liu; Y Y Xue; G L Lv
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

2.  Dynamic light scattering from pulsatile flow in the presence of induced motion artifacts.

Authors:  M Nemati; C N Presura; H P Urbach; N Bhattacharya
Journal:  Biomed Opt Express       Date:  2014-06-10       Impact factor: 3.732

3.  Pulse oximeter signal at various blood flow conditions in an in vitro model.

Authors:  L G Lindberg; M Vegfors; C Lennmarken; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

Review 4.  Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors.

Authors:  Ammar Ahmad Tarar; Umair Mohammad; Soumya K Srivastava
Journal:  Biosensors (Basel)       Date:  2020-05-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.