Factors influencing fetal pulse oximetry performance.

James L Reuss1.   

Abstract

Fetal pulse oximetry shares many problems with traditional pulse oximetry, but also poses unique challenges that may compromise accurate SpO2 determination and data availability. The purpose of this review is to characterize the factors that may influence fetal pulse oximetry and their relationship to sensor design. A review of the literature of pulse oximetry identifies the factors that have been shown to influence fetal pulse oximetry performance, as well as other factors from traditional pulse oximetry that may also be expected to have an effect. Sensor design choices, including monitoring site, wavelength, and configuration, are related to the incidence and mitigation of these factors. Sensor designs may be characterized by monitoring site, means of retention, and operating mode (reflectance versus transmission). The factors influencing fetal pulse oximetry may be categorized as follows: fetal physiology, tissue characteristics at the monitoring site, sensor-tissue interface, and external influences. Monitoring site selection is of paramount importance in reducing the impact of interfering factors on fetal pulse oximetry performance. Many factors of importance in traditional pulse oximetry have yet to be characterized as far as their potential for interference in fetal pulse oximetry.

Mesh:

Substances:

Year:  2004        PMID: 15139579     DOI: 10.1023/b:jocm.0000025278.82852.b3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  67 in total

1.  Effects of anemia on pulse oximetry and continuous mixed venous hemoglobin saturation monitoring in dogs.

Authors:  S Lee; K K Tremper; S J Barker
Journal:  Anesthesiology       Date:  1991-07       Impact factor: 7.892

2.  The effect of caput succedaneum on oxygen saturation measurements.

Authors:  N Johnson; V A Johnson; J Bannister; R J Lilford
Journal:  Br J Obstet Gynaecol       Date:  1990-06

Review 3.  The structure and function of normal and abnormal haemoglobins.

Authors:  T H Huisman
Journal:  Baillieres Clin Haematol       Date:  1993-03

4.  Continuous intrapartum monitoring of fetal oxygen saturation.

Authors:  J Gardosi; M Carter; T Becket
Journal:  Lancet       Date:  1989-09-16       Impact factor: 79.321

Review 5.  Pulse oximetry: technical aspects of machine design.

Authors:  J A Pologe
Journal:  Int Anesthesiol Clin       Date:  1987

6.  Measurement of hemoglobin saturation by oxygen in children and adolescents with sickle cell disease.

Authors:  J P Needleman; B N Setty; L Varlotta; C Dampier; J L Allen
Journal:  Pediatr Pulmonol       Date:  1999-12

7.  Pulse oximetry is a poor predictor of hypoxemia in stable children with sickle cell disease.

Authors:  C J Blaisdell; S Goodman; K Clark; J F Casella; G M Loughlin
Journal:  Arch Pediatr Adolesc Med       Date:  2000-09

8.  Design and validation of pulse oximetry for low saturation.

Authors:  Paul D Mannheimer
Journal:  Anesth Analg       Date:  2002-01       Impact factor: 5.108

9.  Effect of anemia on pulse oximeter accuracy at low saturation.

Authors:  J W Severinghaus; S O Koh
Journal:  J Clin Monit       Date:  1990-04

10.  Fetal pulse oximetry. A methodogical study.

Authors:  A Maesel; L Mårtensson; S Gudmundsson; K Marsál
Journal:  Acta Obstet Gynecol Scand       Date:  1996-02       Impact factor: 3.636

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.