Literature DB >> 23489982

Exploring intra- and inter-reader variability in uni-dimensional, bi-dimensional, and volumetric measurements of solid tumors on CT scans reconstructed at different slice intervals.

Binsheng Zhao1, Yongqiang Tan, Daniel J Bell, Sarah E Marley, Pingzhen Guo, Helen Mann, Marietta L J Scott, Lawrence H Schwartz, Dana C Ghiorghiu.   

Abstract

OBJECTIVE: Understanding magnitudes of variability when measuring tumor size may be valuable in improving detection of tumor change and thus evaluating tumor response to therapy in clinical trials and care. Our study explored intra- and inter-reader variability of tumor uni-dimensional (1D), bi-dimensional (2D), and volumetric (VOL) measurements using manual and computer-aided methods (CAM) on CT scans reconstructed at different slice intervals.
MATERIALS AND METHODS: Raw CT data from 30 patients enrolled in oncology clinical trials was reconstructed at 5, 2.5, and 1.25 mm slice intervals. 118 lesions in the lungs, liver, and lymph nodes were analyzed. For each lesion, two independent radiologists manually and, separately, using computer software, measured the maximum diameter (1D), maximum perpendicular diameter, and volume (CAM only). One of them blindly repeated the measurements. Intra- and inter-reader variability for the manual method and CAM were analyzed using linear mixed-effects models and Bland-Altman method.
RESULTS: For the three slice intervals, the maximum coefficients of variation for manual intra-/inter-reader variability were 6.9%/9.0% (1D) and 12.3%/18.0% (2D), and for CAM were 5.4%/9.3% (1D), 11.3%/18.8% (2D) and 9.3%/18.0% (VOL). Maximal 95% reference ranges for the percentage difference in intra-reader measurements for manual 1D and 2D, and CAM VOL were (-15.5%, 25.8%), (-27.1%, 51.6%), and (-22.3%, 33.6%), respectively.
CONCLUSIONS: Variability in measuring the diameter and volume of solid tumors, manually and by CAM, is affected by CT slice interval. The 2.5mm slice interval provides the least measurement variability. Among the three techniques, 2D has the greatest measurement variability compared to 1D and 3D.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23489982      PMCID: PMC3823057          DOI: 10.1016/j.ejrad.2013.02.018

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  22 in total

1.  New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada.

Authors:  P Therasse; S G Arbuck; E A Eisenhauer; J Wanders; R S Kaplan; L Rubinstein; J Verweij; M Van Glabbeke; A T van Oosterom; M C Christian; S G Gwyther
Journal:  J Natl Cancer Inst       Date:  2000-02-02       Impact factor: 13.506

2.  A pilot study of volume measurement as a method of tumor response evaluation to aid biomarker development.

Authors:  Binsheng Zhao; Geoffrey R Oxnard; Chaya S Moskowitz; Mark G Kris; William Pao; Pingzhen Guo; Valerie M Rusch; Marc Ladanyi; Naiyer A Rizvi; Lawrence H Schwartz
Journal:  Clin Cancer Res       Date:  2010-06-09       Impact factor: 12.531

3.  Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology.

Authors:  Myria Petrou; Leslie E Quint; Bin Nan; Laurence H Baker
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

4.  Variability in size measurement of renal masses smaller than 4 cm on computerized tomography.

Authors:  Sanoj Punnen; Massom A Haider; Gina Lockwood; Fenella Moulding; Martin E O'Malley; Michael A S Jewett
Journal:  J Urol       Date:  2006-12       Impact factor: 7.450

Review 5.  Blinded independent central review of progression-free survival in phase III clinical trials: important design element or unnecessary expense?

Authors:  Lori E Dodd; Edward L Korn; Boris Freidlin; C Carl Jaffe; Lawrence V Rubinstein; Janet Dancey; Margaret M Mooney
Journal:  J Clin Oncol       Date:  2008-08-01       Impact factor: 44.544

6.  The effect of measuring error on the results of therapeutic trials in advanced cancer.

Authors:  C G Moertel; J A Hanley
Journal:  Cancer       Date:  1976-07       Impact factor: 6.860

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Analysis of interobserver and intraobserver variability in CT tumor measurements.

Authors:  K D Hopper; C J Kasales; M A Van Slyke; T A Schwartz; T R TenHave; J A Jozefiak
Journal:  AJR Am J Roentgenol       Date:  1996-10       Impact factor: 3.959

9.  Studies in variation associated with the measurement of solid tumors.

Authors:  P T Lavin; G Flowerdew
Journal:  Cancer       Date:  1980-09-01       Impact factor: 6.860

10.  Volumetric measurement of pulmonary nodules at low-dose chest CT: effect of reconstruction setting on measurement variability.

Authors:  Ying Wang; Geertruida H de Bock; Rob J van Klaveren; Peter van Ooyen; Wim Tukker; Yingru Zhao; Monique D Dorrius; Rozemarijn Vliegenthart Proença; Wendy J Post; Matthijs Oudkerk
Journal:  Eur Radiol       Date:  2009-11-18       Impact factor: 5.315

View more
  39 in total

1.  An Evaluation of Performance Characteristics of Primary Display Devices.

Authors:  Ernest U Ekpo; Mark F McEntee
Journal:  J Digit Imaging       Date:  2016-04       Impact factor: 4.056

2.  Technical Note: FreeCT_ICD: An open-source implementation of a model-based iterative reconstruction method using coordinate descent optimization for CT imaging investigations.

Authors:  John M Hoffman; Frédéric Noo; Stefano Young; Scott S Hsieh; Michael McNitt-Gray
Journal:  Med Phys       Date:  2018-06-01       Impact factor: 4.071

Review 3.  Cancer immunotherapy and immune-related response assessment: The role of radiologists in the new arena of cancer treatment.

Authors:  Mizuki Nishino; Sree H Tirumani; Nikhil H Ramaiya; F Stephen Hodi
Journal:  Eur J Radiol       Date:  2015-03-23       Impact factor: 3.528

4.  Variability in CT lung-nodule volumetry: Effects of dose reduction and reconstruction methods.

Authors:  Stefano Young; Hyun J Grace Kim; Moe Moe Ko; War War Ko; Carlos Flores; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

5.  Accuracy and feasibility of estimated tumour volumetry in primary gastric gastrointestinal stromal tumours: validation using semiautomated technique in 127 patients.

Authors:  Sree Harsha Tirumani; Atul B Shinagare; Ailbhe C O'Neill; Mizuki Nishino; Michael H Rosenthal; Nikhil H Ramaiya
Journal:  Eur Radiol       Date:  2015-05-20       Impact factor: 5.315

6.  A fully automatic end-to-end method for content-based image retrieval of CT scans with similar liver lesion annotations.

Authors:  A B Spanier; N Caplan; J Sosna; B Acar; L Joskowicz
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-11-16       Impact factor: 2.924

7.  Technical Note: FreeCT_wFBP: A robust, efficient, open-source implementation of weighted filtered backprojection for helical, fan-beam CT.

Authors:  John Hoffman; Stefano Young; Frédéric Noo; Michael McNitt-Gray
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

8.  Resampling the N9741 trial to compare tumor dynamic versus conventional end points in randomized phase II trials.

Authors:  Manish R Sharma; Elizabeth Gray; Richard M Goldberg; Daniel J Sargent; Theodore G Karrison
Journal:  J Clin Oncol       Date:  2014-10-27       Impact factor: 44.544

9.  Exploring Variability in CT Characterization of Tumors: A Preliminary Phantom Study.

Authors:  Binsheng Zhao; Yongqiang Tan; Wei Yann Tsai; Lawrence H Schwartz; Lin Lu
Journal:  Transl Oncol       Date:  2014-02-01       Impact factor: 4.243

10.  Radiomics Response Signature for Identification of Metastatic Colorectal Cancer Sensitive to Therapies Targeting EGFR Pathway.

Authors:  Laurent Dercle; Lin Lu; Lawrence H Schwartz; Min Qian; Sabine Tejpar; Peter Eggleton; Binsheng Zhao; Hubert Piessevaux
Journal:  J Natl Cancer Inst       Date:  2020-09-01       Impact factor: 13.506

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.