Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals.

Jung-Hong Ha1, Sang-Shin Park.   

Abstract

OBJECTIVES: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation.
MATERIALS AND METHODS: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test.
RESULTS: Group 4 showed lowest screw-in effect (2.796 ± 0.134) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus.
CONCLUSIONS: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

Entities:  

Keywords:  Glide path; Nickel-titanium file; ProTaper; Screw-in effect; Simulated resin root canal; Torque

Year:  2012        PMID: 23429968      PMCID: PMC3568641          DOI: 10.5395/rde.2012.37.4.215

Source DB:  PubMed          Journal:  Restor Dent Endod        ISSN: 2234-7658


  18 in total

1.  The influence of interfacial forces and duration of filing on root canal shaping.

Authors:  K Gulabivala; S Abdo; M Sherriff; J D Regan
Journal:  Endod Dent Traumatol       Date:  2000-08

2.  Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors.

Authors:  G Gambarini
Journal:  J Endod       Date:  2001-12       Impact factor: 4.171

3.  A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals.

Authors:  Hyung-Hwa Yun; Sung Kyo Kim
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2003-02

4.  Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments.

Authors:  Elio Berutti; Alfonso Roberto Negro; Mario Lendini; Damiano Pasqualini
Journal:  J Endod       Date:  2004-04       Impact factor: 4.171

5.  Effect of pitch length on the behavior of rotary triple helix root canal instruments.

Authors:  Franck Diemer; Paul Calas
Journal:  J Endod       Date:  2004-10       Impact factor: 4.171

6.  Factors affecting the long-term results of endodontic treatment.

Authors:  U Sjogren; B Hagglund; G Sundqvist; K Wing
Journal:  J Endod       Date:  1990-10       Impact factor: 4.171

7.  An initial investigation of the bending and torsional properties of Nitinol root canal files.

Authors:  H M Walia; W A Brantley; H Gerstein
Journal:  J Endod       Date:  1988-07       Impact factor: 4.171

8.  A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments.

Authors:  C R Glossen; R H Haller; S B Dove; C E del Rio
Journal:  J Endod       Date:  1995-03       Impact factor: 4.171

9.  Factors influencing the success of conventional root canal therapy--a five-year retrospective study.

Authors:  C S Smith; D J Setchell; F J Harty
Journal:  Int Endod J       Date:  1993-11       Impact factor: 5.264

10.  Twenty years of endodontic success and failure.

Authors:  D B Swartz; A E Skidmore; J A Griffin
Journal:  J Endod       Date:  1983-05       Impact factor: 4.171

View more
  28 in total

1.  Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation.

Authors:  Sang-Won Kwak; Jung-Hong Ha; WooCheol Lee; Sung-Kyo Kim; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2014-07-16

2.  Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Authors:  Ana Arias; Rupinderpal Singh; Ove A Peters
Journal:  Odontology       Date:  2015-02-21       Impact factor: 2.634

3.  Screw-in forces during instrumentation by various file systems.

Authors:  Jung-Hong Ha; Sang Won Kwak; Sung-Kyo Kim; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2016-11-08

Review 4.  Endodontic Rotary Files, What Should an Endodontist Know?

Authors:  Ana-Belén Dablanca-Blanco; Pablo Castelo-Baz; Ramón Miguéns-Vila; Pablo Álvarez-Novoa; Benjamín Martín-Biedma
Journal:  Medicina (Kaunas)       Date:  2022-05-27       Impact factor: 2.948

5.  Safe root canal preparation using reciprocating nickel-titanium instruments.

Authors:  Jung-Hong Ha
Journal:  Restor Dent Endod       Date:  2015-08

6.  Effect of repetitive pecking at working length for glide path preparation using G-file.

Authors:  Jung-Hong Ha; Hyo-Jin Jeon; Rashid El Abed; Seok-Woo Chang; Sung-Kyo Kim; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2015-01-07

7.  Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study.

Authors:  Alberto Dagna; Rashid El Abed; Sameeha Hussain; Ibrahim H Abu-Tahun; Livia Visai; Federico Bertoglio; Floriana Bosco; Riccardo Beltrami; Claudio Poggio; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2017-10-31

8.  Shot peening increases resistance to cyclic fatigue fracture of endodontic files.

Authors:  Javier Nino-Barrera; Jose Sanchez-Aleman; Manuel Acosta-Humanez; Luis Gamboa-Martinez; Carlos Cortes-Rodriguez
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

9.  Influence of a glide path on the dentinal crack formation of ProTaper Next system.

Authors:  Sevinç Aktemur Türker; Emel Uzunoğlu
Journal:  Restor Dent Endod       Date:  2015-09-02

10.  Cyclic Fatigue Resistance and Force Generated by OneShape Instruments during Curved Canal Preparation.

Authors:  Zhuyu Wang; Wen Zhang; Xiaolei Zhang
Journal:  PLoS One       Date:  2016-08-11       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.