Literature DB >> 15448466

Effect of pitch length on the behavior of rotary triple helix root canal instruments.

Franck Diemer1, Paul Calas.   

Abstract

The behavior of nickel-titanium instruments depends largely on the cross-section of the working part. The effect of pitch length was evaluated using two instruments with the same cross-section (triple helix; 0.6% taper). One had a short pitch (0.5 mm at the tip to 0.9 mm at 16 mm at the end of the working part). The other had a long pitch (1.18 mm/2 mm). A dynamometer recorded tensional stress (MHz) and the tendency to screw in (Fz) during simulated canal preparations. Rotational speed was kept constant, and a continuous pecking movement was used. At the end of the preparations, the average Fz was 5.02 N for the short-pitch instrument and 1.47 N for the long-pitch instrument (p < 0.001). The average Mz varied from 0.88 N (short pitch) to 0.35 N (long pitch). Increasing the pitch decreased torsional load sharing and the tendency to screw in.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15448466     DOI: 10.1097/01.don.0000125877.26495.69

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals.

Authors:  Jung-Hong Ha; Sang-Shin Park
Journal:  Restor Dent Endod       Date:  2012-11-21

2.  Screw-in forces during instrumentation by various file systems.

Authors:  Jung-Hong Ha; Sang Won Kwak; Sung-Kyo Kim; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2016-11-08

3.  A comparative study of mechanical resistance of two reciprocating files.

Authors:  Dario Di Nardo; Massimo Galli; Antonio Morese; Marco Seracchiani; Valerio Ferri; Gabriele Miccoli; Gianluca Gambarini; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-03-01

4.  Comparison of two canal preparation techniques using mtwo rotary instruments.

Authors:  Faeze Hamze; Kiamars Honardar; Kiumars Nazarimoghadam
Journal:  Iran Endod J       Date:  2011-11-15

5.  The impact of clinical use on the torsional behavior of Reciproc and WaveOne instruments.

Authors:  Rafael Rodrigues Soares de Magalhães; Lígia Carolina Moreira Braga; Érika Sales Joviano Pereira; Isabella Faria da Cunha Peixoto; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
Journal:  J Appl Oral Sci       Date:  2016 Jul-Aug       Impact factor: 2.698

6.  Evaluation of canal transportation after preparation with Reciproc single-file systems with or without glide path files.

Authors:  Ugur Aydin; Emrah Karataslioglu
Journal:  J Conserv Dent       Date:  2017 Jul-Aug

7.  Geometric and dimensional characteristics of simulated curved canals prepared with proTaper instruments.

Authors:  Renata de Castro Martins; Maria Guiomar de Azevedo Bahia; Vicente Tadeu Lopes Buono
Journal:  J Appl Oral Sci       Date:  2010 Jan-Feb       Impact factor: 2.698

8.  Comparison of Screw-In Forces during Movement of Endodontic Files with Different Geometries, Alloys, and Kinetics.

Authors:  Sang Won Kwak; Chan-Joo Lee; Sung Kyo Kim; Hyeon-Cheol Kim; Jung-Hong Ha
Journal:  Materials (Basel)       Date:  2019-05-08       Impact factor: 3.623

9.  Comparative evaluation of apically extruded debris during root canal instrumentation using two Ni-Ti single file rotary systems: An in vitro study.

Authors:  Kiran Singbal; Disha Jain; Kranthi Raja; Tan Ming Hoe
Journal:  J Conserv Dent       Date:  2017 Mar-Apr
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.