Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Ana Arias1, Rupinderpal Singh2, Ove A Peters2.   

Abstract

A new rotary instrument has been developed to simplify the glide path preparation in root canals before shaping procedures. The purpose of this study was to compare the peak torque and force induced by nickel-titanium PathFile multiple-instrument system and the recently developed M-Wire ProGlider single instrument during glide path preparation of mesial root canals in extracted mandibular molars. Each independent canal of eight mesial roots of mandibular molars was randomly assigned to achieve a reproducible glide path with a new set of either PathFile #1 and #2 or ProGlider after negotiation with a 10 K-file. Tests were run in a standardized fashion using a torque-testing platform. Peak torque (N cm) and force (N) were registered and analysis of variance and Tukey post-hoc tests were applied. Preliminary data for stationary torque at failure were also obtained and compared with peak torque for each instrument. PathFile #1 and #2 instruments showed statistically lower peak torque (p = 0.001) and peak force (p = 0.008) than ProGlider. Torque at failure according to ADA No. 28/ISO 36030-1 was not significantly different from peak torque during glide path preparation for ProGlider instruments while it was significantly higher for PathFile #1 and #2 (p < 0.001). Under the conditions of this study, PathFile instruments developed significant lower peak torque and force during glide path preparation compared to ProGlider, which is possibly subjected to a greater contact with the canal walls due to the increase in its flute diameter at middle and coronal levels.

Entities:  

Keywords:  Glide path; M-Wire; PathFile; ProGlider; Torque

Mesh:

Substances:

Year:  2015        PMID: 25701538     DOI: 10.1007/s10266-015-0199-0

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  38 in total

1.  Impact of two theoretical cross-sections on torsional and bending stresses of nickel-titanium root canal instrument models.

Authors:  Y L Turpin; F Chagneau; J M Vulcain
Journal:  J Endod       Date:  2000-07       Impact factor: 4.171

2.  Bending properties of rotary nickel-titanium instruments.

Authors:  Edgar Schäfer; Anita Dzepina; Gholamreza Danesh
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2003-12

3.  The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments.

Authors:  David D Roland; Wallis E Andelin; David F Browning; G-Hong Robert Hsu; Mahmoud Torabinejad
Journal:  J Endod       Date:  2002-07       Impact factor: 4.171

4.  Analysis of torque and force with differently tapered rotary endodontic instruments in vitro.

Authors:  Charlotte Schrader; Ove A Peters
Journal:  J Endod       Date:  2005-02       Impact factor: 4.171

5.  Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instruments.

Authors:  Maria Guiomar Azevedo Bahia; Marta C C Melo; Vicente Tadeu Lopes Buono
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2005-09-30

6.  Dimensional characterization and mechanical behaviour of K3 rotary instruments.

Authors:  M C C Melo; E S J Pereira; A C D Viana; A M A Fonseca; V T L Buono; M G A Bahia
Journal:  Int Endod J       Date:  2008-01-19       Impact factor: 5.264

7.  Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals.

Authors:  Elio Berutti; Giuseppe Cantatore; Arnaldo Castellucci; Giorgio Chiandussi; Francesco Pera; Giuseppe Migliaretti; Damiano Pasqualini
Journal:  J Endod       Date:  2009-03       Impact factor: 4.171

8.  Flexibility and torsional behaviour of rotary nickel-titanium PathFile, RaCe ISO 10, Scout RaCe and stainless steel K-File hand instruments.

Authors:  R K L Nakagawa; J L Alves; V T L Buono; M G A Bahia
Journal:  Int Endod J       Date:  2013-07-02       Impact factor: 5.264

9.  Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.

Authors:  Natasha C C Ajuz; Luciana Armada; Lucio S Gonçalves; Gilberto Debelian; José F Siqueira
Journal:  J Endod       Date:  2013-02-12       Impact factor: 4.171

10.  An in vitro comparison of torsional stress and cyclic fatigue resistance of ProFile GT and ProFile GT Series X rotary nickel-titanium files.

Authors:  Thomas R Kramkowski; James Bahcall
Journal:  J Endod       Date:  2009-03       Impact factor: 4.171

View more
  1 in total

Review 1.  Present status and future directions: Canal shaping.

Authors:  Ana Arias; Ove A Peters
Journal:  Int Endod J       Date:  2022-02-16       Impact factor: 5.165