A new apparatus for brain imaging: four-head rotating gamma camera single-photon emission computed tomograph.

K Kimura1, K Hashikawa, H Etani, A Uehara, T Kozuka, H Moriwaki, Y Isaka, M Matsumoto, T Kamada, H Moriyama.   

Abstract

The development of a new rotating gamma camera SPECT device for imaging the brain was undertaken with the objective of achieving the highest full volume imaging spatial and temporal resolution performance. For this purpose, four rectangular gamma camera detectors were arranged as close to the head as possible, and united in a block to insure detector head registration and alignment as well as to enable rotation stability at high speeds. Phantom and clinical studies performed demonstrated 42 sequential, 4-mm thick transaxial images acquired in one scan and with sufficient volume to permit the entire cerebrum and cerebellum to be imaged with high sensitivity. The central field of view reconstructed spatial resolution measured 7.0 mm full width of half maximum utilizing the high-resolution collimator, and tomographic images of arbitrary planes including sagittal and coronal demonstrated equally high resolution. The high sensitivity and high speed rotational acquisition capability of the device permits dynamic SPECT studies to be carried out in the analysis of rapidly varying radiotracer concentrations.

Mesh:

Year:  1990        PMID: 2341896

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  13 in total

1.  Distribution of cortical benzodiazepine receptor binding in right-handed healthy humans: a voxel-based statistical analysis of iodine 123 iomazenil SPECT with partial volume correction.

Authors:  H Kato; E Shimosegawa; K Isohashi; N Kimura; H Kazui; J Hatazawa
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

Review 2.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

Review 3.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

Review 4.  Collimator design for single photon emission tomography.

Authors:  S C Moore; K Kouris; I Cullum
Journal:  Eur J Nucl Med       Date:  1992

5.  Physical assessment of the GE/CGR Neurocam and comparison with a single rotating gamma-camera.

Authors:  K Kouris; P H Jarritt; D C Costa; P J Ell
Journal:  Eur J Nucl Med       Date:  1992

Review 6.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

7.  Improvement of brain single photon emission tomography (SPET) using transmission data acquisition in a four-head SPET scanner.

Authors:  K Murase; S Tanada; T Inoue; Y Sugawara; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1993-01

Review 8.  Multidetector single-photon emission tomography: are two (or three or four) heads really better than one?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1993-05

9.  An evaluation of the accelerated expectation maximization algorithms for single-photon emission tomography image reconstruction.

Authors:  K Murase; S Tanada; Y Sugawara; W N Tauxe; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1994-07

10.  Heterogeneity of cerebral blood flow in Alzheimer disease and vascular dementia.

Authors:  Takuya Yoshikawa; Kenya Murase; Naohiko Oku; Masao Imaizumi; Masashi Takasawa; Piao Rishu; Yasuyuki Kimura; Yoshitaka Ikejiri; Kazuo Kitagawa; Masatsugu Hori; Jun Hatazawa
Journal:  AJNR Am J Neuroradiol       Date:  2003-08       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.