Literature DB >> 1547808

Quantitative analysis in single photon emission tomography (SPET).

K A Blokland1, H H Reiber, E K Pauwels.   

Abstract

Quantitative analysis can improve the sensitivity and specificity of single photon emission tomography (SPET) procedures, as well as reduce inter- and intraobserver variabilities. Quantification of the radioactivity distribution is the ultimate goal of SPET. In this review we consider the basic requirements for an optimum three-dimensional reconstruction of the radionuclide distribution to enable quantification. Attenuation and scatter correction as well as varying resolution are the major problems. In the older SPET systems quantification was hampered by the lack of system sensitivity and sufficient computer power. Therefore, the imaging system was often assumed to be shift invariant and linear and the attenuation throughout the object uniform. More sophisticated solutions have been proposed and with more or less success implemented, but not for application in daily practice. Knowledge (measurement) of the attenuation is often required. New generation SPET systems employing multi-detectors and super minicomputers will ease the implementation of these solutions.

Mesh:

Year:  1992        PMID: 1547808     DOI: 10.1007/bf00178308

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  63 in total

1.  "CORT-EX:" a program for quantitative analysis of brain SPECT data.

Authors:  G Lamoureux; R M Dupont; W L Ashburn; S E Halpern
Journal:  J Nucl Med       Date:  1990-11       Impact factor: 10.057

Review 2.  Quantitative SPECT in radiation dosimetry.

Authors:  P B Zanzonico; R E Bigler; G Sgouros; A Strauss
Journal:  Semin Nucl Med       Date:  1989-01       Impact factor: 4.446

3.  Interactive three-dimensional region of interest analysis of HMPAO SPECT brain studies.

Authors:  H R Hooper; A J McEwan; B C Lentle; T L Kotchon; P M Hooper
Journal:  J Nucl Med       Date:  1990-12       Impact factor: 10.057

4.  The multislice cylinder: a new approach to quantification of cardiac single photon emission tomography.

Authors:  D L Stone; S H Snyder; S Jaffe; A T Weiss; M S Gotsman; H Atlan
Journal:  Nucl Med Commun       Date:  1989-06       Impact factor: 1.690

5.  SPECT Compton-scattering correction by analysis of energy spectra.

Authors:  K F Koral; X Q Wang; W L Rogers; N H Clinthorne; X H Wang
Journal:  J Nucl Med       Date:  1988-02       Impact factor: 10.057

6.  Determination of the optimum filter function for SPECT imaging.

Authors:  D R Gilland; B M Tsui; W H McCartney; J R Perry; J Berg
Journal:  J Nucl Med       Date:  1988-05       Impact factor: 10.057

7.  A new thresholding method for volume determination by SPECT.

Authors:  L Mortelmans; J Nuyts; G Van Pamel; V Van den Maegdenbergh; M De Roo; P Suetens
Journal:  Eur J Nucl Med       Date:  1986

8.  Subtraction of Compton-scattered photons in single-photon emission computerized tomography.

Authors:  B Axelsson; P Msaki; A Israelsson
Journal:  J Nucl Med       Date:  1984-04       Impact factor: 10.057

9.  Quantitative thallium-201 exercise scintigraphy for detection of coronary artery disease.

Authors:  B C Berger; D D Watson; G J Taylor; G B Craddock; R P Martin; C D Teates; G A Beller
Journal:  J Nucl Med       Date:  1981-07       Impact factor: 10.057

Review 10.  A practical SPECT technique for quantitation of drug delivery to human tumors and organ absorbed radiation dose.

Authors:  G Iosilevsky; O Israel; A Frenkel; E Even-Sapir; S Ben-Haim; A Front; G M Kolodny; D Front
Journal:  Semin Nucl Med       Date:  1989-01       Impact factor: 4.446

View more
  3 in total

1.  Quantitative evaluation of myocardial single-photon emission tomographic imaging: application to the measurement of perfusion defect size and severity.

Authors:  T Benoit; D Vivegnis; J Foulon; P Rigo
Journal:  Eur J Nucl Med       Date:  1996-12

2.  Expectation maximization in quantitative single-photon emission tomography.

Authors:  A K Blokland
Journal:  Eur J Nucl Med       Date:  1994-07

3.  Validation of quantitative brain dopamine D2 receptor imaging with a conventional single-head SPET camera.

Authors:  P Nikkinen; K Liewendahl; S Savolainen; J Launes
Journal:  Eur J Nucl Med       Date:  1993-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.