Improvement of brain single photon emission tomography (SPET) using transmission data acquisition in a four-head SPET scanner.

K Murase1, S Tanada, T Inoue, Y Sugawara, K Hamamoto.   

Abstract

Attenuation coefficient maps (mu-maps) are a useful way to compensate for non-uniform attenuation when performing single photon emission tomography (SPET). A new method was developed to record single photon transmission data and a mu-map for the brain was produced using a four-head SPET scanner. Transmission data were acquired by a gamma camera opposite to a flood radioactive source attached to one of four gamma cameras in the four-head SPET scanner. Attenuation correction was performed using the iterative expectation maximization algorithm and the mu-map. Phantom studies demonstrated that this method could reconstruct the distribution of radioactivity more accurately than conventional methods, even for a severely non-uniform mu-map, and could improve the quality of SPET images. Clinical application to technetium-99m hexamethyl-propylene amine oxime (HMPAO) brain SPET also demonstrated the usefulness of this method. Thus, this method appears to be promising for improvement in the image quality and quantitative accuracy of brain SPET.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8420780     DOI: 10.1007/bf02261243

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  21 in total

1.  Technique for the use of standard outlines for attenuation correction and quantification in SPECT.

Authors:  J S Fleming
Journal:  Nucl Med Commun       Date:  1990-10       Impact factor: 1.690

2.  Imaging of the human torso using cone-beam transmission CT implemented on a rotating gamma camera.

Authors:  S H Manglos; D A Bassano; F D Thomas; Z D Grossman
Journal:  J Nucl Med       Date:  1992-01       Impact factor: 10.057

3.  Accelerated iterative reconstruction for positron emission tomography based on the em algorithm for maximum likelihood estimation.

Authors:  R M Lewitt; G Muehllehner
Journal:  IEEE Trans Med Imaging       Date:  1986       Impact factor: 10.048

4.  Improved iterative image reconstruction with automatic noise artifact suppression.

Authors:  E Tanaka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

5.  Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method.

Authors:  H Almquist; J Palmer; M Ljungberg; P Wollmer; S E Strand; B Jonson
Journal:  Eur J Nucl Med       Date:  1990

6.  Correction of nonuniform attenuation in cardiac SPECT imaging.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; J G Ballard; J R Perry; W H McCartney; J Berg
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

7.  Attenuation correction in SPECT based on transmission studies and Monte Carlo simulations of build-up functions.

Authors:  M Ljungberg; S E Strand
Journal:  J Nucl Med       Date:  1990-04       Impact factor: 10.057

8.  A new apparatus for brain imaging: four-head rotating gamma camera single-photon emission computed tomograph.

Authors:  K Kimura; K Hashikawa; H Etani; A Uehara; T Kozuka; H Moriwaki; Y Isaka; M Matsumoto; T Kamada; H Moriyama
Journal:  J Nucl Med       Date:  1990-05       Impact factor: 10.057

9.  The luxury-perfusion syndrome and its possible relation to acute metabolic acidosis localised within the brain.

Authors:  N A Lassen
Journal:  Lancet       Date:  1966-11-19       Impact factor: 79.321

10.  Improved SPECT quantification using compensation for scattered photons.

Authors:  R J Jaszczak; K L Greer; C E Floyd; C C Harris; R E Coleman
Journal:  J Nucl Med       Date:  1984-08       Impact factor: 10.057

View more
  3 in total

1.  Simultaneous emission and transmission measurements as an adjunct to dynamic planar gamma camera studies.

Authors:  D L Bailey; M Robinson; S R Meikle; P T Bye
Journal:  Eur J Nucl Med       Date:  1996-03

2.  Expectation maximization in quantitative single-photon emission tomography.

Authors:  A K Blokland
Journal:  Eur J Nucl Med       Date:  1994-07

3.  An evaluation of the accelerated expectation maximization algorithms for single-photon emission tomography image reconstruction.

Authors:  K Murase; S Tanada; Y Sugawara; W N Tauxe; K Hamamoto