Literature DB >> 7957344

An evaluation of the accelerated expectation maximization algorithms for single-photon emission tomography image reconstruction.

K Murase1, S Tanada, Y Sugawara, W N Tauxe, K Hamamoto.   

Abstract

We previously reported that brain single-photon emission tomography (SPET) images could be improved by using an attenuation coefficient map constructed with transmission data and the iterative expectation maximization (EM) algorithm. However, the conventional EM algorithm (CEM) typically requires 30-80 iterations to provide acceptable results, limiting its clinical applicability. Several methods have been proposed to accelerate the EM algorithm. The purpose of this study was to search for a practical method for accelerating the EM algorithm. The methods investigated here include the accelerated EM algorithm (ACEM) using additive correction, ACEM using multiplicative correction, and Tanaka's filtered iterative reconstruction method (FIR). These methods were assessed by simulated SPET studies of a phantom incorporating nonuniform attenuation and by reference to clinical brain SPET data. In the simulation studies, the above methods were evaluated by using three parameters (root mean square error, log likelihood value, and contrast recovery coefficient); the results showed that FIR had an advantage over other methods in terms of all parameters. The results obtained using the clinical data demonstrated that FIR could reconstruct acceptable images in only five iterations. These results show that FIR offers significant advantages over CEM or other ACEMs, indicating that FIR can make the EM algorithm practical for clinical use in SPET.

Mesh:

Year:  1994        PMID: 7957344     DOI: 10.1007/BF00285580

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  10 in total

1.  Accelerated iterative reconstruction for positron emission tomography based on the em algorithm for maximum likelihood estimation.

Authors:  R M Lewitt; G Muehllehner
Journal:  IEEE Trans Med Imaging       Date:  1986       Impact factor: 10.048

2.  Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions.

Authors:  J S Liow; S C Strother
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

3.  A fast reconstruction algorthm for stationary positron emission tomography based on a modified em algorithm.

Authors:  E Tanaka
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

4.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

5.  Correction of nonuniform attenuation in cardiac SPECT imaging.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; J G Ballard; J R Perry; W H McCartney; J Berg
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

6.  A new apparatus for brain imaging: four-head rotating gamma camera single-photon emission computed tomograph.

Authors:  K Kimura; K Hashikawa; H Etani; A Uehara; T Kozuka; H Moriwaki; Y Isaka; M Matsumoto; T Kamada; H Moriyama
Journal:  J Nucl Med       Date:  1990-05       Impact factor: 10.057

7.  A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT).

Authors:  K Murase; H Itoh; H Mogami; M Ishine; M Kawamura; A Iio; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1987

8.  The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction.

Authors:  J S Liow; S C Strother
Journal:  Phys Med Biol       Date:  1993-01       Impact factor: 3.609

9.  Improvement of brain single photon emission tomography (SPET) using transmission data acquisition in a four-head SPET scanner.

Authors:  K Murase; S Tanada; T Inoue; Y Sugawara; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1993-01

10.  Improved SPECT quantification using compensation for scattered photons.

Authors:  R J Jaszczak; K L Greer; C E Floyd; C C Harris; R E Coleman
Journal:  J Nucl Med       Date:  1984-08       Impact factor: 10.057

  10 in total
  2 in total

1.  A non-negative fast multiplicative algorithm in 3D scatter-compensated SPET reconstruction.

Authors:  S H Walrand; L R van Elmbt; S Pauwels
Journal:  Eur J Nucl Med       Date:  1996-11

2.  Expectation maximization in quantitative single-photon emission tomography.

Authors:  A K Blokland
Journal:  Eur J Nucl Med       Date:  1994-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.