The GE/CGR Neurocam is a triple-headed single photon emission tomography (SPET) system dedicated to multi-slice brain tomography. We have assessed its physical performance in terms of sensitivity and resolution, and its clinical efficacy in comparison with a modern, single rotating gamma-camera (GE 400XCT). Using a water-filled cylinder containing technetium-99m, the tomographic volume sensitivity of the Neurocam was 30.0 and 50.7 kcps/MBq.ml.cm for the high-resolution (HR) and general-purpose (GP) collimators, respectively; the corresponding values for the single rotating camera were 7.6 and 12.8 kcps/(MBq/ml)/cm. Tomographic resolution was measured in air and in water. In air, the Neurocam resolution at the cente of the field-of-view (FOV) is 9.0 and 10.7 mm full width at half-maximum (FWHM) with the HR and GP collimators, respectively, and is isotropic in the three orthogonal planes; the resolution of the GE 400XCT with 13 cm radius of rotation is 10.3 and 11.7 mm, respectively. For the Neurocam with the HR collimator, the transaxial FWHM values in water were 9.7 mm at the centre and 9.5 mm radial (6.6 mm tangential) at 8 cm from the centre. The physical characteristics of the Neurocam enable the routine acquisition of brain perfusion data with technetium-99m hexamethyl-propylene amine oxime (99mTc-HMPAO) in about 14 min, yielding better image quality than with a single rotating camera in 40 min.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1597238     DOI: 10.1007/bf00175135

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  9 in total

1.  Brain perfusion SPECT using an annular single crystal camera: initial clinical experience.

Authors:  B L Holman; P A Carvalho; R E Zimmerman; K A Johnson; S S Tumeh; A P Smith; S Genna
Journal:  J Nucl Med       Date:  1990-09       Impact factor: 10.057

2.  The geometric transfer function for cone and fan beam collimators.

Authors:  B M Tsui; G T Gullberg
Journal:  Phys Med Biol       Date:  1990-01       Impact factor: 3.609

3.  Collimator selection for SPECT brain imaging: the advantage of high resolution.

Authors:  S P Mueller; J F Polak; M F Kijewski; B L Holman
Journal:  J Nucl Med       Date:  1986-11       Impact factor: 10.057

4.  A new apparatus for brain imaging: four-head rotating gamma camera single-photon emission computed tomograph.

Authors:  K Kimura; K Hashikawa; H Etani; A Uehara; T Kozuka; H Moriwaki; Y Isaka; M Matsumoto; T Kamada; H Moriyama
Journal:  J Nucl Med       Date:  1990-05       Impact factor: 10.057

5.  Advances in emission tomography: quo vadis?

Authors:  T F Budinger
Journal:  J Nucl Med       Date:  1990-05       Impact factor: 10.057

6.  Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT.

Authors:  J M Links; R W Jeremy; S M Dyer; T L Frank; L C Becker
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

7.  Design and clinical utility of a fan beam collimator for SPECT imaging of the head.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; D R Gilland; J R Perry; W H McCartney
Journal:  J Nucl Med       Date:  1986-06       Impact factor: 10.057

8.  Determination of the optimum filter function for SPECT imaging.

Authors:  D R Gilland; B M Tsui; W H McCartney; J R Perry; J Berg
Journal:  J Nucl Med       Date:  1988-05       Impact factor: 10.057

9.  A special cut-off gamma camera for high-resolution SPECT of the head.

Authors:  S A Larsson; G Bergstrand; H Bergstedt; J Berg; O Flygare; P O Schnell; N Andersson; C Lagergren
Journal:  J Nucl Med       Date:  1984-09       Impact factor: 10.057

  9 in total
  5 in total

1.  Error analysis of autoradiography method for measurement of cerebral blood flow by 123I-IMP brain SPECT: a comparison study with table look-up method and microsphere model method.

Authors:  H Ito; K Ishii; H Atsumi; Y Inukai; S Abe; M Sato; T Kinoshita; R Kawashima; S Ono; H Fukuda
Journal:  Ann Nucl Med       Date:  1995-11       Impact factor: 2.668

2.  Psychiatric profiles and patterns of cerebral blood flow in focal epilepsy: interactions between depression, obsessionality, and perfusion related to the laterality of the epilepsy.

Authors:  E B Schmitz; J Moriarty; D C Costa; H A Ring; P J Ell; M R Trimble
Journal:  J Neurol Neurosurg Psychiatry       Date:  1997-05       Impact factor: 10.154

3.  A clinical role for 99mTc-HMPAO SPECT in the investigation of dementia?

Authors:  P R Talbot; J J Lloyd; J S Snowden; D Neary; H J Testa
Journal:  J Neurol Neurosurg Psychiatry       Date:  1998-03       Impact factor: 10.154

4.  HMPAO SPECT in Parkinson's disease before and after levodopa: correlation with dopaminergic responsiveness.

Authors:  H S Markus; D C Costa; A J Lees
Journal:  J Neurol Neurosurg Psychiatry       Date:  1994-02       Impact factor: 10.154

5.  Error analysis of table look-up method for cerebral blood flow measurement by 123I-IMP brain SPECT: comparison with conventional microsphere model method.

Authors:  H Ito; K Ishii; H Atsumi; T Kinoshita; R Kawashima; S Ono; S Yoshioka; H Iida; K Uemura; H Fukuda
Journal:  Ann Nucl Med       Date:  1995-05       Impact factor: 2.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.