Literature DB >> 29519412

A constrained linear regression optimization algorithm for diaphragm motion tracking with cone beam CT projections.

Jie Wei1, Ming Chao2.   

Abstract

PURPOSE: We presented a feasibility study to extract the diaphragm motion from the inferior contrast cone beam computed tomography (CBCT) projection images using a constrained linear regression optimization algorithm.
METHODS: The shape of the diaphragm was fitted by a parabolic function which was initialized by five manually placed points on the diaphragm contour of a pre-selected projection. A constrained linear regression model by exploiting the spatial, algebraic, and temporal constraints of the diaphragm, approximated by a parabola, was employed to estimate the parameters. The algorithm was assessed by a fluoroscopic movie acquired at anterior-posterior (AP) fixed direction and kilovoltage CBCT projection image sets from four lung and two liver patients using the Varian 21iX Clinac. The automatic tracing by the proposed algorithm and manual tracking were compared in both space and frequency domains for the algorithm evaluations.
RESULTS: The error between the results estimated by the proposed algorithm and those by manual tracking for the AP fluoroscopic movie was 0.54 mm with standard deviation (SD) of 0.45 mm. For the detected projections the average error was 0.79 mm with SD of 0.64 mm for all six enrolled patients and the maximum deviation was 2.5 mm. The mean sub-millimeter accuracy outcome exhibits the feasibility of the proposed constrained linear regression approach to track the diaphragm motion on rotational fluoroscopic images.
CONCLUSION: The new algorithm will provide a potential solution to rendering diaphragm motion and possibly aiding the tumor target tracking in radiation therapy of thoracic/abdominal cancer patients.
Copyright © 2018 Associazione Italiana di Fisica Medica. All rights reserved.

Entities:  

Keywords:  Cone beam CT projections; Diaphragm motion; Radiation therapy; Tumor motion management

Mesh:

Year:  2018        PMID: 29519412      PMCID: PMC7336257          DOI: 10.1016/j.ejmp.2018.01.005

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  35 in total

1.  Inverse planning incorporating organ motion.

Authors:  J G Li; L Xing
Journal:  Med Phys       Date:  2000-07       Impact factor: 4.071

2.  Robotic motion compensation for respiratory movement during radiosurgery.

Authors:  A Schweikard; G Glosser; M Bodduluri; M J Murphy; J R Adler
Journal:  Comput Aided Surg       Date:  2000

3.  Markerless tracking of small lung tumors for stereotactic radiotherapy.

Authors:  John R van Sörnsen de Koste; Max Dahele; Hassan Mostafavi; Alex Sloutsky; Suresh Senan; Ben J Slotman; Wilko F A R Verbakel
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

4.  Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers.

Authors:  Ross I Berbeco; Hassan Mostafavi; Gregory C Sharp; Steve B Jiang
Journal:  Phys Med Biol       Date:  2005-09-13       Impact factor: 3.609

5.  2D/4D marker-free tumor tracking using 4D CBCT as the reference image.

Authors:  Mengjiao Wang; Gregory C Sharp; Simon Rit; Vivien Delmon; Guangzhi Wang
Journal:  Phys Med Biol       Date:  2014-04-08       Impact factor: 3.609

6.  Relation of external surface to internal tumor motion studied with cine CT.

Authors:  Pai-Chun Melinda Chi; Peter Balter; Dershan Luo; Radhe Mohan; Tinsu Pan
Journal:  Med Phys       Date:  2006-09       Impact factor: 4.071

7.  Reduction of cardiac volume in left-breast treatment fields by respiratory maneuvers: a CT study.

Authors:  H M Lu; E Cash; M H Chen; L Chin; W J Manning; J Harris; B Bornstein
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-01       Impact factor: 7.038

8.  Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy.

Authors:  Yoshikazu Tsunashima; Takeji Sakae; Yoshiyuki Shioyama; Kenji Kagei; Toshiyuki Terunuma; Akihiro Nohtomi; Yasuyuki Akine
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-11-01       Impact factor: 7.038

9.  Extracting respiratory signals from thoracic cone beam CT projections.

Authors:  Hao Yan; Xiaoyu Wang; Wotao Yin; Tinsu Pan; Moiz Ahmad; Xuanqin Mou; Laura Cerviño; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2013-02-11       Impact factor: 3.609

10.  CT- guided transthoracic fine needle aspiration of pulmonary lesions: accuracy and complications in 294 patients.

Authors:  Sulhattin Arslan; Adnan Yilmaz; Birol Bayramgürler; Ozlem Uzman; Edhem Nver; Esen Akkaya
Journal:  Med Sci Monit       Date:  2002-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.