Literature DB >> 23358947

An approach to rapid calculation of temperature change in tissue using spatial filters to approximate effects of thermal conduction.

Giuseppe Carluccio1, Danilo Erricolo, Sukhoon Oh, Christopher M Collins.   

Abstract

We present an approach to performing rapid calculations of temperature within tissue by interleaving, at regular time intervals, 1) an analytical solution to the Pennes (or other desired) bioheat equation excluding the term for thermal conduction and 2) application of a spatial filter to approximate the effects of thermal conduction. Here, the basic approach is presented with attention to filter design. The method is applied to a few different cases relevant to magnetic resonance imaging, and results are compared to those from a full finite-difference (FD) implementation of the Pennes bioheat equation. It is seen that results of the proposed method are in reasonable agreement with those of the FD approach, with about 15% difference in the calculated maximum temperature increase, but are calculated in a fraction of the time, requiring less than 2% of the calculation time for the FD approach in the cases evaluated.

Entities:  

Mesh:

Year:  2013        PMID: 23358947      PMCID: PMC4040531          DOI: 10.1109/TBME.2013.2241764

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  17 in total

1.  MR imaging of RF heating using a paramagnetic doped agarose phantom.

Authors:  E M Shapiro; A Borthakur; R Reddy
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  Fast FFT-based bioheat transfer equation computation.

Authors:  Jean-Louis Dillenseger; Simon Esneault
Journal:  Comput Biol Med       Date:  2010-02       Impact factor: 4.589

3.  SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate.

Authors:  C M Collins; S Li; M B Smith
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

4.  Simulation studies promote technological development of radiofrequency phased array hyperthermia.

Authors:  P Wust; M Seebass; J Nadobny; P Deuflhard; G Mönich; R Felix
Journal:  Int J Hyperthermia       Date:  1996 Jul-Aug       Impact factor: 3.914

5.  A computer simulation of radio-frequency ablation of the endocardium.

Authors:  S Labonté
Journal:  IEEE Trans Biomed Eng       Date:  1994-09       Impact factor: 4.538

6.  Computational techniques for fast hyperthermia temperature optimization.

Authors:  S K Das; S T Clegg; T V Samulski
Journal:  Med Phys       Date:  1999-02       Impact factor: 4.071

7.  Simultaneous B1 + homogenization and specific absorption rate hotspot suppression using a magnetic resonance phased array transmit coil.

Authors:  Cornelis A T Van den Berg; Bob van den Bergen; Jeroen B Van de Kamer; Bas W Raaymakers; Hugo Kroeze; Lambertus W Bartels; Jan J W Lagendijk
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

8.  Numerical modeling of temperature distributions within the neonatal head.

Authors:  G M Van Leeuwen; J W Hand; J J Lagendijk; D V Azzopardi; A D Edwards
Journal:  Pediatr Res       Date:  2000-09       Impact factor: 3.756

Review 9.  Thresholds for thermal damage to normal tissues: an update.

Authors:  Pavel S Yarmolenko; Eui Jung Moon; Chelsea Landon; Ashley Manzoor; Daryl W Hochman; Benjamin L Viglianti; Mark W Dewhirst
Journal:  Int J Hyperthermia       Date:  2011       Impact factor: 3.914

10.  Experimental and numerical assessment of MRI-induced temperature change and SAR distributions in phantoms and in vivo.

Authors:  Sukhoon Oh; Andrew G Webb; Thomas Neuberger; BuSik Park; Christopher M Collins
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

View more
  17 in total

1.  Q-r curve of thermal tomography and its clinical application on breast tumor diagnosis.

Authors:  Guilian Shi; Fei Han; Lin Wang; Chengwen Liang; Kaiyang Li
Journal:  Biomed Opt Express       Date:  2015-03-03       Impact factor: 3.732

2.  Parallel transmission RF pulse design with strict temperature constraints.

Authors:  Cem M Deniz; Giuseppe Carluccio; Christopher Collins
Journal:  NMR Biomed       Date:  2017-02-10       Impact factor: 4.044

3.  Magnetic resonance temperature imaging-based quantification of blood flow-related energy losses.

Authors:  Christopher Dillon; Robert Roemer; Allison Payne
Journal:  NMR Biomed       Date:  2015-05-14       Impact factor: 4.044

4.  Measurement of SAR-induced temperature increase in a phantom and in vivo with comparison to numerical simulation.

Authors:  Sukhoon Oh; Yeun-Chul Ryu; Giuseppe Carluccio; Christopher T Sica; Christopher M Collins
Journal:  Magn Reson Med       Date:  2013-06-26       Impact factor: 4.668

5.  Array-compressed parallel transmit pulse design.

Authors:  Zhipeng Cao; Xinqiang Yan; William A Grissom
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

6.  Direct control of the temperature rise in parallel transmission by means of temperature virtual observation points: Simulations at 10.5 Tesla.

Authors:  Nicolas Boulant; Xiaoping Wu; Gregor Adriany; Sebastian Schmitter; Kamil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2015-03-05       Impact factor: 4.668

7.  Toward imaging the body at 10.5 tesla.

Authors:  M Arcan Ertürk; Xiaoping Wu; Yiğitcan Eryaman; Pierre-François Van de Moortele; Edward J Auerbach; Russell L Lagore; Lance DelaBarre; J Thomas Vaughan; Kâmil Uğurbil; Gregor Adriany; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2016-10-21       Impact factor: 4.668

8.  Optimization of the order and spacing of sequences in an MRI exam to reduce the maximum temperature and thermal dose.

Authors:  Giuseppe Carluccio; Christopher M Collins
Journal:  Magn Reson Med       Date:  2018-10-17       Impact factor: 4.668

9.  Predicting long-term temperature increase for time-dependent SAR levels with a single short-term temperature response.

Authors:  Giuseppe Carluccio; Mary Bruno; Christopher M Collins
Journal:  Magn Reson Med       Date:  2015-06-22       Impact factor: 4.668

10.  A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI.

Authors:  M Arcan Ertürk; Alexander J E Raaijmakers; Gregor Adriany; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2016-02-17       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.