Literature DB >> 17326185

Simultaneous B1 + homogenization and specific absorption rate hotspot suppression using a magnetic resonance phased array transmit coil.

Cornelis A T Van den Berg1, Bob van den Bergen, Jeroen B Van de Kamer, Bas W Raaymakers, Hugo Kroeze, Lambertus W Bartels, Jan J W Lagendijk.   

Abstract

In high-field MRI severe problems with respect to B(1) (+) uniformity and specific absorption rate (SAR) deposition pose a great challenge to whole-body imaging. In this study the potential of a phased array transmit coil is investigated to simultaneously reduce B(1) (+) nonuniformity and SAR deposition. This was tested by performing electromagnetic simulations of a phased array TEM coil operating at 128 MHz loaded with two different homogeneous elliptical phantoms and four dielectric patient models. It was shown that the wave interference of a circularly polarized RF field with an ellipse and a pelvis produces largely identical B(1) (+) and electric field patterns. Especially for obese patients, this results in large B(1) (+) nonuniformity and global areas with elevated SAR deposition. It is demonstrated that a phased array transmit coil can reduce these phenomena. The technique was especially successful in suppressing SAR hotspots with a decrease up to 50%. The application of optimized settings for an ellipse to the patient models leads to comparable results as obtained with the patient-specific optimizations. This suggests that generic phase/amplitude port settings are possible, requiring no preinformation about patient-specific RF fields. Such a scheme would, due to its simultaneous B(1) (+) homogenization and extra SAR margin, have many benefits for whole-body imaging at 3 T.

Entities:  

Mesh:

Year:  2007        PMID: 17326185     DOI: 10.1002/mrm.21149

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

2.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements.

Authors:  Gregory J Metzger; Carl Snyder; Can Akgun; Tommy Vaughan; Kamil Ugurbil; Pierre-Francois Van de Moortele
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

3.  Tissue Border Enhancement by inversion recovery MRI at 7.0 Tesla.

Authors:  Mauro Costagli; Douglas A C Kelley; Mark R Symms; Laura Biagi; Riccardo Stara; Eleonora Maggioni; Gianluigi Tiberi; Carmen Barba; Renzo Guerrini; Mirco Cosottini; Michela Tosetti
Journal:  Neuroradiology       Date:  2014-04-25       Impact factor: 2.804

4.  Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 Tesla.

Authors:  Gregory J Metzger; Edward J Auerbach; Can Akgun; Josh Simonson; Xiaoming Bi; Kâmil Uğurbil; Pierre-François van de Moortele
Journal:  Magn Reson Med       Date:  2012-03-22       Impact factor: 4.668

5.  Measurement of SAR-induced temperature increase in a phantom and in vivo with comparison to numerical simulation.

Authors:  Sukhoon Oh; Yeun-Chul Ryu; Giuseppe Carluccio; Christopher T Sica; Christopher M Collins
Journal:  Magn Reson Med       Date:  2013-06-26       Impact factor: 4.668

Review 6.  Fetal magnetic resonance imaging: jumping from 1.5 to 3 tesla (preliminary experience).

Authors:  Teresa Victoria; Diego Jaramillo; Timothy Paul Leslie Roberts; Deborah Zarnow; Ann Michelle Johnson; Jorge Delgado; Erika Rubesova; Arastoo Vossough
Journal:  Pediatr Radiol       Date:  2014-03-27

Review 7.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

8.  Specific absorption rate studies of the parallel transmission of inner-volume excitations at 7T.

Authors:  Adam C Zelinski; Leonardo M Angelone; Vivek K Goyal; Giorgio Bonmassar; Elfar Adalsteinsson; Lawrence L Wald
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

Review 9.  Biological effects and safety in magnetic resonance imaging: a review.

Authors:  Valentina Hartwig; Giulio Giovannetti; Nicola Vanello; Massimo Lombardi; Luigi Landini; Silvana Simi
Journal:  Int J Environ Res Public Health       Date:  2009-06-10       Impact factor: 3.390

10.  Understanding and manipulating the RF fields at high field MRI.

Authors:  Tamer S Ibrahim; Yik-Kiong Hue; Lin Tang
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.